These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 1314288)

  • 1. Mechanical failure of hydroxyapatite- and polysulfone-coated titanium rods in a weight-bearing canine model.
    Shen WJ; Chung KC; Wang GJ; McLaughlin RE
    J Arthroplasty; 1992 Mar; 7(1):43-9. PubMed ID: 1314288
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants.
    Dalton JE; Cook SD; Thomas KA; Kay JF
    J Bone Joint Surg Am; 1995 Jan; 77(1):97-110. PubMed ID: 7822360
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hydroxyapatite-coating on titanium arc sprayed titanium implants.
    Nakashima Y; Hayashi K; Inadome T; Uenoyama K; Hara T; Kanemaru T; Sugioka Y; Noda I
    J Biomed Mater Res; 1997 Jun; 35(3):287-98. PubMed ID: 9138063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions.
    Søballe K; Hansen ES; B-Rasmussen H; Jørgensen PH; Bünger C
    J Orthop Res; 1992 Mar; 10(2):285-99. PubMed ID: 1311039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gap healing enhanced by hydroxyapatite coating in dogs.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Hjortdal VE; Juhl GI; Pedersen CM; Hvid I; Bünger C
    Clin Orthop Relat Res; 1991 Nov; (272):300-7. PubMed ID: 1657476
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hydroxyapatite-coated titanium for orthopedic implant applications.
    Cook SD; Thomas KA; Kay JF; Jarcho M
    Clin Orthop Relat Res; 1988 Jul; (232):225-43. PubMed ID: 2838208
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical and histological evaluation of hydroxyapatite-coated, titanium-coated and grit-blasted surfaces under weight-bearing conditions.
    Dávid A; Eitenmüller J; Muhr G; Pommer A; Bär HF; Ostermann PA; Schildhauer TA
    Arch Orthop Trauma Surg; 1995; 114(2):112-8. PubMed ID: 7734232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study.
    Yang CY; Wang BC; Lee TM; Chang E; Chang GL
    J Biomed Mater Res; 1997 Jul; 36(1):39-48. PubMed ID: 9212387
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants.
    Hayashi K; Inadome T; Mashima T; Sugioka Y
    J Biomed Mater Res; 1993 May; 27(5):557-63. PubMed ID: 8314808
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of tissue reaction and osteointegration of metal implants between hydroxyapatite/Ti alloy coat: an animal experimental study.
    Itiravivong P; Promasa A; Laiprasert T; Techapongworachai T; Kuptniratsaikul S; Thanakit V; Heimann RB
    J Med Assoc Thai; 2003 Jun; 86 Suppl 2():S422-31. PubMed ID: 12930020
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical failure of hydroxyapatite-coated titanium and cobalt-chromium-molybdenum alloy implants. An animal study.
    Nimb L; Gotfredsen K; Steen Jensen J
    Acta Orthop Belg; 1993; 59(4):333-8. PubMed ID: 8116363
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fixation of titanium and hydroxyapatite-coated implants in arthritic osteopenic bone.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Hjortdal VE; Juhl GI; Pedersen CM; Hvid I; Bünger C
    J Arthroplasty; 1991 Dec; 6(4):307-16. PubMed ID: 1663154
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Histological and mechanical comparison of hydroxyapatite-coated cobalt-chrome and titanium implants in the rabbit femur.
    Friedman RJ; Bauer TW; Garg K; Jiang M; An YH; Draughn RA
    J Appl Biomater; 1995; 6(4):231-5. PubMed ID: 8589507
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength.
    Hayashi K; Inadome T; Tsumura H; Nakashima Y; Sugioka Y
    Biomaterials; 1994 Nov; 15(14):1187-91. PubMed ID: 7534485
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings.
    Hacking SA; Tanzer M; Harvey EJ; Krygier JJ; Bobyn JD
    Clin Orthop Relat Res; 2002 Dec; (405):24-38. PubMed ID: 12461353
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Pedersen CM; Bünger C
    Acta Orthop Scand; 1990 Aug; 61(4):299-306. PubMed ID: 2402977
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bone graft incorporation around titanium-alloy- and hydroxyapatite-coated implants in dogs.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Pedersen CM; Bünger C
    Clin Orthop Relat Res; 1992 Jan; (274):282-93. PubMed ID: 1729014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Osseointegration of a hydroxyapatite-coated multilayered mesh stem.
    Kusakabe H; Sakamaki T; Nihei K; Oyama Y; Yanagimoto S; Ichimiya M; Kimura J; Toyama Y
    Biomaterials; 2004 Jul; 25(15):2957-69. PubMed ID: 14967528
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant-delivered Alendronate Causes a Dose-dependent Response on Net Bone Formation Around Porous Titanium Implants in Canines.
    Pura JA; Bobyn JD; Tanzer M
    Clin Orthop Relat Res; 2016 May; 474(5):1224-33. PubMed ID: 26831478
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Histological and biomechanical analysis of bone and interface reactions around hydroxyapatite-coated intramedullary implants of different stiffness: a pilot study on the goat.
    Buma P; van Loon PJ; Versleyen H; Weinans H; Slooff TJ; de Groot K; Huiskes R
    Biomaterials; 1997 Sep; 18(18):1251-60. PubMed ID: 9300560
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.