These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 1325023)

  • 21. Relaxivity corrected response modulated excitation (RME): a T2-corrected technique achieving specified magnetization patterns from an RF pulse and a time-varying magnetic field.
    Pearlman JD; Wieczorek TJ
    Magn Reson Med; 1994 Sep; 32(3):388-95. PubMed ID: 7984071
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.
    Ma J; Wismans C; Cao Z; Klomp DWJ; Wijnen JP; Grissom WA
    Magn Reson Med; 2018 Jan; 79(1):31-40. PubMed ID: 28370494
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Short T2 tissue imaging with the Pointwise Encoding Time reduction with Radial Acquisition (PETRA) sequence: the additional value of fat saturation and subtraction in the meniscus.
    Lee YH; Suh JS; Grodzki D
    Magn Reson Imaging; 2015 May; 33(4):385-9. PubMed ID: 25614216
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The dependence of nuclear magnetic resonance (NMR) image contrast on intrinsic and pulse sequence timing parameters.
    Wehrli FW; MacFall JR; Glover GH; Grigsby N; Haughton V; Johanson J
    Magn Reson Imaging; 1984; 2(1):3-16. PubMed ID: 6530915
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Selective saturation in magnetization transfer experiments.
    McGowan JC; Leigh JS
    Magn Reson Med; 1994 Oct; 32(4):517-22. PubMed ID: 7997119
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Magnetic resonance properties of hydrogen: imaging the posterior fossa.
    Young IR; Burl M; Clarke GJ; Hall AS; Pasmore T; Collins AG; Smith DT; Orr JS; Bydder GM; Doyle FH; Greenspan RH; Steiner RE
    AJR Am J Roentgenol; 1981 Nov; 137(5):895-901. PubMed ID: 6975014
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Myocardial microcirculation in humans--new approaches using MRI].
    Wacker CM; Bauer WR
    Herz; 2003 Mar; 28(2):74-81. PubMed ID: 12669220
    [TBL] [Abstract][Full Text] [Related]  

  • 28. WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy.
    Ogg RJ; Kingsley PB; Taylor JS
    J Magn Reson B; 1994 May; 104(1):1-10. PubMed ID: 8025810
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Magnetization transfer by simple sequences of rectangular pulses.
    Forster J; Schick F; Pfeffer M; Lutz O
    MAGMA; 1995 Jul; 3(2):83-93. PubMed ID: 7496890
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Water suppression in 1H magnetic resonance images by the generation of multiple-quantum coherence.
    Dumoulin CL; Vatis D
    Magn Reson Med; 1986 Apr; 3(2):282-8. PubMed ID: 3713492
    [TBL] [Abstract][Full Text] [Related]  

  • 31. 31P spectroscopic localization using pinwheel NMR excitation pulses.
    Hardy CJ; Bottomley PA
    Magn Reson Med; 1991 Feb; 17(2):315-27. PubMed ID: 2062206
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Reproducibility of relaxation and spin-density parameters in phantoms and the human brain measured by MR imaging at 1.5 T.
    Breger RK; Wehrli FW; Charles HC; MacFall JR; Haughton VM
    Magn Reson Med; 1986 Oct; 3(5):649-62. PubMed ID: 3784884
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Minimization of diffusive attenuation in T2-weighted NMR images of porous solids using turboSPI.
    Beyea SD; Bremner TW; Balcom BJ
    Solid State Nucl Magn Reson; 2006 Jun; 29(4):267-71. PubMed ID: 16226019
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Separation of lipid and water MR imaging signals by chopper averaging in the time domain.
    Szumowski J; Plewes DB
    Radiology; 1987 Oct; 165(1):247-50. PubMed ID: 3628777
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fast broadband inversion by adiabatic pulses.
    Hwang TL; van Zijl PC; Garwood M
    J Magn Reson; 1998 Jul; 133(1):200-3. PubMed ID: 9654487
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Off-resonance pulsed magnetization transfer in clinical MR imaging: optimization by an analysis of transients.
    Listerud J
    Magn Reson Med; 1997 May; 37(5):693-705. PubMed ID: 9126943
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Relaxation-compensated CEST-MRI at 7 T for mapping of creatine content and pH--preliminary application in human muscle tissue in vivo.
    Rerich E; Zaiss M; Korzowski A; Ladd ME; Bachert P
    NMR Biomed; 2015 Nov; 28(11):1402-12. PubMed ID: 26374674
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cooperative T1 and T2 effects on contrast using a new driven inversion spin-echo (DISE) MRI pulse sequence.
    Conturo TE; Kessler RM; Beth AH
    Magn Reson Med; 1990 Sep; 15(3):397-419. PubMed ID: 2233220
    [TBL] [Abstract][Full Text] [Related]  

  • 39. MR fingerprinting using the quick echo splitting NMR imaging technique.
    Jiang Y; Ma D; Jerecic R; Duerk J; Seiberlich N; Gulani V; Griswold MA
    Magn Reson Med; 2017 Mar; 77(3):979-988. PubMed ID: 26924639
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Diagnostic value of T1 and T2 * relaxation times and off-resonance saturation effects in the evaluation of Achilles tendinopathy by MRI at 3T.
    Grosse U; Syha R; Hein T; Gatidis S; Grözinger G; Schabel C; Martirosian P; Schick F; Springer F
    J Magn Reson Imaging; 2015 Apr; 41(4):964-73. PubMed ID: 24817378
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.