These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 13494664)

  • 1. The reliability of the thermodilution method for determination of the cardiac output and the blood flow in central veins.
    FEGLER G
    Q J Exp Physiol Cogn Med Sci; 1957 Jul; 42(3):254-66. PubMed ID: 13494664
    [No Abstract]   [Full Text] [Related]  

  • 2. Understanding techniques for measuring cardiac output.
    Taylor BC; Sheffer DB
    Biomed Instrum Technol; 1990; 24(3):188-97. PubMed ID: 2188704
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac output measurement with a simplified thermodilution technique. Comparison with the Fick method.
    Sibille L; Prasquier R; Vallois JM; Gaudebout C; Pocidalo JJ
    Biomedicine; 1975 Feb; 23(2):64-7. PubMed ID: 239762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Significance of the thermodilution method in cardiovascular diagnostics].
    Schwingshackl H; Dienstl F; Amor H; Wilflingseder S
    Wien Z Inn Med; 1972; 53(1):1-16. PubMed ID: 4559055
    [No Abstract]   [Full Text] [Related]  

  • 5. [The thermodilution method for the understanding of heart function].
    Rutishauser W; Krayenbühl HP; Wirz P; Veragut UP; Lüthy E
    Arztl Forsch; 1966 Nov; 20(11):569-72. PubMed ID: 4871501
    [No Abstract]   [Full Text] [Related]  

  • 6. Respiration and measurement of cardiac output by thermodilution and central or peripheral dye dilution.
    Delhaas T; Mook GA; Zijlstra WG
    J Appl Physiol (1985); 1992 Sep; 73(3):1047-51. PubMed ID: 1400016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a new method to measure cardiac output during extracorporeal detoxification.
    Nikiforov YV; Kisluchine VV; Chaus NI
    ASAIO J; 1996; 42(5):M903-5. PubMed ID: 8945017
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flow-regulated extracorporeal arteriovenous tubing loop for cardiac output measurements by ultrasound velocity dilution: validation in post-cardiac surgery intensive care unit patients.
    Eremenko AA; Safarov PN
    ASAIO J; 2010; 56(6):522-6. PubMed ID: 21245798
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Coronary flow determination by the thermodilution method].
    Warembourg H; Houdas Y; Bertrand ME; Delomez M; Ketelers JY
    Arch Mal Coeur Vaiss; 1969 Feb; 62(2):173-82. PubMed ID: 4983186
    [No Abstract]   [Full Text] [Related]  

  • 10. A new technique for measurement of cardiac output by thermodilution in man.
    Ganz W; Donoso R; Marcus HS; Forrester JS; Swan HJ
    Am J Cardiol; 1971 Apr; 27(4):392-6. PubMed ID: 4929422
    [No Abstract]   [Full Text] [Related]  

  • 11. Measurement of cardiac output in anaesthetized animals by a thermodilution method.
    FEGLER G
    Q J Exp Physiol Cogn Med Sci; 1954; 39(3):153-64. PubMed ID: 13194838
    [No Abstract]   [Full Text] [Related]  

  • 12. In vivo correlation of thermodilution cardiac output and videodensitometric indicator-dilution curves obtained from contrast two-dimensional echocardiograms.
    DeMaria AN; Bommer W; Kwan OL; Riggs K; Smith M; Waters J
    J Am Coll Cardiol; 1984 Apr; 3(4):999-1004. PubMed ID: 6368645
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcutaneous fluorescence dilution cardiac output and circulating blood volume during hemorrhagic hypovolemia.
    Maarek JM; Holschneider DP; Yang J; Pniak SN; Rubinstein EH
    Anesthesiology; 2005 Apr; 102(4):774-82. PubMed ID: 15791107
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiac output measurements. A review of current techniques and research.
    Ehlers KC; Mylrea KC; Waterson CK; Calkins JM
    Ann Biomed Eng; 1986; 14(3):219-39. PubMed ID: 3532871
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thermodilution method overestimates low cardiac output in humans.
    van Grondelle A; Ditchey RV; Groves BM; Wagner WW; Reeves JT
    Am J Physiol; 1983 Oct; 245(4):H690-2. PubMed ID: 6624939
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro evaluation of the thermodilution technique for the measurement of ventricular stroke volume and end-diastolic volume.
    Salgado CR; Galletti PM
    Cardiologia (Basel); 1966; 49(2):65-78. PubMed ID: 5335243
    [No Abstract]   [Full Text] [Related]  

  • 17. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method.
    Engoren M; Barbee D
    Am J Crit Care; 2005 Jan; 14(1):40-5. PubMed ID: 15608107
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Determination of cardiac output with thermodilution method. Effect of indicator passage through the pulmonary circulation in normal and low flow].
    Pavek K; Arfors K; Malmberg P
    Nord Med; 1971 Jun; 85(22):701. PubMed ID: 4932507
    [No Abstract]   [Full Text] [Related]  

  • 19. Invasive diagnostics.
    Liander B
    Acta Med Scand Suppl; 1981; 652():57-67. PubMed ID: 7036662
    [No Abstract]   [Full Text] [Related]  

  • 20. Evaluation of a lithium dilution cardiac output technique as a method for measurement of cardiac output in anesthetized cats.
    Beaulieu KE; Kerr CL; McDonell WN
    Am J Vet Res; 2005 Sep; 66(9):1639-45. PubMed ID: 16261840
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.