These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 1357164)

  • 1. Comparison of tensile strength of solder joints by infrared and conventional torch technique.
    Cattaneo G; Wagnild G; Marshall G; Watanabe L
    J Prosthet Dent; 1992 Jul; 68(1):33-7. PubMed ID: 1357164
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical properties of metal connectors soldered by gas torch versus an infrared technique.
    Cheng AC; Chai JY; Gilbert J; Jameson LM
    J Prosthodont; 1993 Jun; 2(2):103-9. PubMed ID: 7902170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical and elemental characterization of solder joints and welds using a gold-palladium alloy.
    Wiskott HW; Macheret F; Bussy F; Belser UC
    J Prosthet Dent; 1997 Jun; 77(6):607-16. PubMed ID: 9185054
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of soldering methods on tensile strength of a gold-palladium metal ceramic alloy.
    Ghadhanfari HA; Khajah HM; Monaco EA; Kim H
    J Prosthet Dent; 2014 Oct; 112(4):994-1000. PubMed ID: 24840906
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microstructure, mechanical performance and corrosion properties of base metal solder joints.
    Machha S; Kumar MV; ; Rangarajan V
    Indian J Dent Res; 2011; 22(4):614. PubMed ID: 22124071
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative analysis of two techniques for soldered connectors.
    Tehini GE; Stein RS
    J Prosthet Dent; 1993 Jan; 69(1):16-9. PubMed ID: 8095985
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of stiffness and microstructure of joints soldered with gas-oxygen torch and infrared methods.
    Cheng AC; Chai JY; Gilbert J; Jameson LM
    J Prosthet Dent; 1994 Jul; 72(1):8-15. PubMed ID: 7916054
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tensile strength of preceramic solder joints formed using an infrared heat source.
    Louly AC; Mora AF; Moore BK; Andres CJ; Goodacre CJ
    Int J Prosthodont; 1991; 4(5):425-31. PubMed ID: 1687435
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of three soldering techniques on the strength of high-palladium alloy solder joints.
    Chaves M; Vermilyea SG; Papazoglou E; Brantley WA
    J Prosthet Dent; 1998 Jun; 79(6):677-84. PubMed ID: 9627897
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of infrared- and torch-soldering of Au-Pd and Co-Cr metal-ceramic alloys using a high-fusing solder.
    Dominici JT; Sobczak KP; Mitchell RJ
    J Prosthodont; 1995 Jun; 4(2):101-10. PubMed ID: 8528438
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Torch versus oven preceramic soldering of a nickel-chromium alloy.
    Sobieralski JA; Schelb E; Prihoda TJ
    Quintessence Int; 1990 Sep; 21(9):753-7. PubMed ID: 1982740
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tensile strength analysis of midpontic soldering.
    Ferencz JL
    J Prosthet Dent; 1987 Jun; 57(6):696-703. PubMed ID: 2884306
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An investigation of tensile strength of dental solder joints.
    Rasmussen EJ; Goodkind RJ; Gerberich WW
    J Prosthet Dent; 1979 Apr; 41(4):418-23. PubMed ID: 34035
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Strength properties of preceramic brazed joints of a gold-palladium alloy with a microwave-assisted oven and gas/oxygen torch technique.
    Kim H; Prasad S; Dunford R; Monaco EA
    J Prosthet Dent; 2014 Sep; 112(3):606-12. PubMed ID: 24656408
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of the strength of base metal and gold solder joints.
    Kriebel R; Moore BK; Goodacre CJ; Dykema RW
    J Prosthet Dent; 1984 Jan; 51(1):60-6. PubMed ID: 6142109
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of laser-weld joint opening size on fatigue strength of Ti-6Al-4V structures with several diameters.
    Nuñez-Pantoja JM; Vaz LG; Nóbilo MA; Henriques GE; Mesquita MF
    J Oral Rehabil; 2011 Mar; 38(3):196-201. PubMed ID: 20678101
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Study on postsoldering of Ni-Cr ceramic alloys. Effect of soldering temperature and atmosphere].
    Ishigure K
    Aichi Gakuin Daigaku Shigakkai Shi; 1990 Mar; 28(1 Pt 1):21-41. PubMed ID: 1983731
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint.
    Lee SY; Lee JH
    J Adv Prosthodont; 2010 Dec; 2(4):117-21. PubMed ID: 21264189
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative tensile strengths of preceramic and postceramic solder connectors using high-palladium alloy.
    Shehab AH; Pappas M; Burns DR; Douglas H; Moon PC
    J Prosthet Dent; 2005 Feb; 93(2):148-52. PubMed ID: 15674225
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Joining titanium materials with tungsten inert gas welding, laser welding, and infrared brazing.
    Wang RR; Welsch GE
    J Prosthet Dent; 1995 Nov; 74(5):521-30. PubMed ID: 8809260
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.