BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 135765)

  • 21. A collagen coated vascular prosthesis.
    Scott SM; Gaddy LR; Sahmel R; Hoffman H
    J Cardiovasc Surg (Torino); 1987; 28(5):498-504. PubMed ID: 2958479
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model.
    Wilson GJ; MacGregor DC; Klement P; Weber BA; Binnington AG; Pinchuk L
    ASAIO J; 1993; 39(3):M526-31. PubMed ID: 8268591
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The effect of preclotting on surface thrombogenicity and thromboembolic complications of Dacron grafts in the canine thoracic aorta.
    Gloviczki P; Hollier LH; Hoffman EA; Plate G; Trastek VF; Kaye MP
    J Thorac Cardiovasc Surg; 1984 Aug; 88(2):253-8. PubMed ID: 6235404
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Small-caliber arterial prostheses: influence of porosity].
    Ratto GB; Motta G
    J Chir (Paris); 1983 May; 120(5):337-42. PubMed ID: 6223934
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A rapid in vitro test of the in vivo healing potential of vascular prostheses.
    Mathisen SR; Coan DE; Sauvage LR; Wu HD; Wechezak AR; Goff SG
    J Biomed Mater Res; 1987 Sep; 21(9):1081-91. PubMed ID: 2959664
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Modification of polyethylene terephthalate (Dacron) via denier reduction: effects on material tensile strength, weight, and protein binding capabilities.
    Phaneuf MD; Quist WC; Bide MJ; LoGerfo FW
    J Appl Biomater; 1995; 6(4):289-99. PubMed ID: 8589514
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of the endothelialization of small intestinal submucosa, dacron, and expanded polytetrafluoroethylene suspended in the thoracoabdominal aorta in sheep.
    Yavuz K; Geyik S; Pavcnik D; Uchida BT; Corless CL; Hartley DE; Goktay A; Correa LO; Timmermans H; Hodde JP; Kaufman JA; Keller FS; Rösch J
    J Vasc Interv Radiol; 2006 May; 17(5):873-82. PubMed ID: 16687754
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Long-term results in the dog carotid artery with small lumen vascular prostheses with microvascular endothelial cells].
    Pasic M; Müller-Glauser W; Lachat M; Bittmann P; von Segesser LK; Turina M
    Helv Chir Acta; 1993 Dec; 60(3):381-5. PubMed ID: 8119818
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Differentiation of vascular prostheses in dogs with serial tests of in vivo platelet reactivity.
    Clagett GP; Graeber GM; Robinowitz M; Langloss JM; Ramwell PW
    Surgery; 1984 Mar; 95(3):331-8. PubMed ID: 6230746
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Morphology of the deposits formed during "preclotting" of dacron vascular prostheses. Scanning electron microscopy study].
    Guidoin RG; Gosselin C; Awad JA; Rouleau C; Haggis GH; Turcot J
    Union Med Can; 1974 Aug; 103(8):1374-81. PubMed ID: 4277238
    [No Abstract]   [Full Text] [Related]  

  • 31. Polyester prostheses as substitutes in the thoracic aorta of dogs. I. Evaluation of commercial prostheses.
    Guidoin R; Gosselin C; Martin L; Marois M; Laroche F; King M; Gunasekera K; Domurado D; Sigot-Luizard MF; Blais P
    J Biomed Mater Res; 1983 Nov; 17(6):1049-77. PubMed ID: 6228554
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Healing pattern of small caliber dacron grafts in the baboon: an animal model for the study of vascular prostheses.
    Keough EM; Callow AD; Connolly RJ; Weinberg KS; Aalberg JJ; O'Donnell TF
    J Biomed Mater Res; 1984 Mar; 18(3):281-92. PubMed ID: 6232280
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A third generation of ascending aorta Dacron graft: preliminary experience.
    De Paulis R; Scaffa R; Maselli D; Salica A; Bellisario A; Weltert L
    Ann Thorac Surg; 2008 Jan; 85(1):305-9. PubMed ID: 18154829
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Long-term evaluation of a new selectively biodegradable vascular graft coated with polyethylene oxide-polylactic acid for right ventricular conduit. An experimental study.
    Uretzky G; Appelbaum Y; Younes H; Udassin R; Nataf P; Baccioglu E; Pizof G; Borman JB; Cohn D
    J Thorac Cardiovasc Surg; 1990 Nov; 100(5):769-76. PubMed ID: 2146448
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Vascular graft replacement of the ascending and descending aorta: do Dacron grafts grow?
    Etz CD; Homann T; Silovitz D; Bodian CA; Luehr M; Di Luozzo G; Plestis KA; Griepp RB
    Ann Thorac Surg; 2007 Oct; 84(4):1206-12; discussion 1212-3. PubMed ID: 17888971
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fate of polyester arterial prostheses implanted as thoraco-abdominal by-passes in dogs: haematology, pathology, and biochemistry.
    Merhi Y; Guidoin R; Forest JC
    Clin Invest Med; 1988 Dec; 11(6):403-16. PubMed ID: 2976332
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Polyethylene terephtalate (Dacron) prostheses as arterial substitutes. Value of commercial grafts as abdominal aorta substitutes in the dog (author's transl)].
    Guidoin R; Levaillant PA; Marois M; Gosselin C; Martin L; Rouleau C; Garneau P; Noel HP; Blais P
    J Mal Vasc; 1980; 5(1):3-12. PubMed ID: 6450812
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Experimental study of implantation of autologous vascular endothelial cells on dacron grafts].
    Luo G; Guan H; Xiao M
    Zhonghua Wai Ke Za Zhi; 1995 Oct; 33(10):623-5. PubMed ID: 8731900
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pyrolytic carbon-coated Dacron grafts.
    Sharp WV; Teague PC
    Surg Forum; 1978; 29():218-20. PubMed ID: 162600
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Seeding of autogenous endothelial cells to the inner surface of small-caliber dacron vascular prostheses: an experimental study in dogs].
    Zhang H; Wang ZG; Xia RY
    Zhonghua Wai Ke Za Zhi; 1988 Feb; 26(2):68-70, 124. PubMed ID: 2973406
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.