These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. Artefacts in continuous ECG recordings--provoking and preventing manoeuvres. Lönnblad J; Nilsson G; Folke M; Hök B; Lindén M; Bäcklund Y Scand Cardiovasc J; 2005 Jul; 39(3):167-71. PubMed ID: 16146979 [TBL] [Abstract][Full Text] [Related]
8. ECG acquisition errors due to arm leads placed on the chest. Greenfield JC; Rembert JC J Electrocardiol; 2009; 42(3):235-7. PubMed ID: 19095246 [No Abstract] [Full Text] [Related]
9. A simple measure to control for variations in chest electrodes placement in serial electrocardiogram recordings. Soliman EZ J Electrocardiol; 2008; 41(5):378-9. PubMed ID: 18620704 [TBL] [Abstract][Full Text] [Related]
10. How many ECG leads do we need? Trägårdh E; Engblom H; Pahlm O Cardiol Clin; 2006 Aug; 24(3):317-30, vii. PubMed ID: 16939826 [TBL] [Abstract][Full Text] [Related]
11. Precordial low voltage in patients with ascites. Cuculi F; Jamshidi P; Kobza R; Rohacek M; Erne P Europace; 2008 Jan; 10(1):96-8. PubMed ID: 18003635 [TBL] [Abstract][Full Text] [Related]
12. Accuracy of ECG electrode placement by emergency department clinicians. McCann K; Holdgate A; Mahammad R; Waddington A Emerg Med Australas; 2007 Oct; 19(5):442-8. PubMed ID: 17919217 [TBL] [Abstract][Full Text] [Related]
13. Enhancing interference rejection of preamplified electrodes by automated gain adaption. Degen T; Jäckel H IEEE Trans Biomed Eng; 2004 Nov; 51(11):2031-9. PubMed ID: 15536905 [TBL] [Abstract][Full Text] [Related]
14. False ST elevation in a modified 12-lead surface electrocardiogram. Toosi MS; Sochanski MT J Electrocardiol; 2008; 41(3):197-201. PubMed ID: 18342880 [TBL] [Abstract][Full Text] [Related]
15. A flatline lead I results from bilateral arm-to-leg electrode exchange. Hoffman I J Electrocardiol; 2008; 41(5):388-90. PubMed ID: 18358484 [TBL] [Abstract][Full Text] [Related]
16. Can electrocardiogram electrodes replace bispectral index electrodes for monitoring depth of anesthesia? Akavipat P; Dumrongbul K; Neamnak P J Med Assoc Thai; 2006 Jan; 89(1):51-5. PubMed ID: 16583581 [TBL] [Abstract][Full Text] [Related]
17. Intraindividual variability in electrocardiograms. Schijvenaars BJ; van Herpen G; Kors JA J Electrocardiol; 2008; 41(3):190-6. PubMed ID: 18358483 [TBL] [Abstract][Full Text] [Related]
18. Cardiac monitoring. Part 2-- Recording a 12-lead ECG. Jevon P Nurs Times; 2007 Jan 9-15; 103(2):26-7. PubMed ID: 17278731 [No Abstract] [Full Text] [Related]
19. Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice. Sejersten M; Wagner GS; Pahlm O; Warren JW; Feldman CL; Horácek BM J Electrocardiol; 2007 Apr; 40(2):120-6. PubMed ID: 17067621 [TBL] [Abstract][Full Text] [Related]
20. Proximal placement of limb electrodes: a potential solution for acquiring standard electrocardiogram waveforms from monitoring electrode positions. Pahlm O; Wagner GS J Electrocardiol; 2008; 41(6):454-7. PubMed ID: 18805543 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]