These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

344 related articles for article (PubMed ID: 13679651)

  • 1. The calibrated automated thrombogram (CAT): a universal routine test for hyper- and hypocoagulability.
    Hemker HC; Giesen P; AlDieri R; Regnault V; de Smed E; Wagenvoord R; Lecompte T; Béguin S
    Pathophysiol Haemost Thromb; 2002; 32(5-6):249-53. PubMed ID: 13679651
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Thrombinography: towards a globalization of coagulation tests].
    Péters P; Gothot A
    Rev Med Liege; 2009 Apr; 64(4):199-203. PubMed ID: 19514539
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibrated automated thrombin generation measurement in clotting plasma.
    Hemker HC; Giesen P; Al Dieri R; Regnault V; de Smedt E; Wagenvoord R; Lecompte T; Béguin S
    Pathophysiol Haemost Thromb; 2003; 33(1):4-15. PubMed ID: 12853707
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Thrombin generation assays: accruing clinical relevance.
    Hemker HC; Al Dieri R; Béguin S
    Curr Opin Hematol; 2004 May; 11(3):170-5. PubMed ID: 15257016
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thrombin generation, a function test of the haemostatic-thrombotic system.
    Hemker HC; Al Dieri R; De Smedt E; Béguin S
    Thromb Haemost; 2006 Nov; 96(5):553-61. PubMed ID: 17080210
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low agreement between fresh and frozen-thawed platelet-rich plasma in the calibrated automated thrombogram assay.
    Ljungkvist M; Lövdahl S; Zetterberg E; Berntorp E
    Haemophilia; 2017 May; 23(3):e214-e218. PubMed ID: 28145076
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurements of endogenous thrombin potential using the CAT method in cats: Reference values and influence of the direct factor Xa inhibitor apixaban.
    Mischke R; Teuber M; Tiede A
    Res Vet Sci; 2019 Dec; 127():113-121. PubMed ID: 31693942
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations.
    Duarte RCF; Ferreira CN; Rios DRA; Reis HJD; Carvalho MDG
    Rev Bras Hematol Hemoter; 2017; 39(3):259-265. PubMed ID: 28830606
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thrombin generation in plasma of healthy adults and children: chromogenic versus fluorogenic thrombogram analysis.
    Devreese K; Wijns W; Combes I; Van kerckhoven S; Hoylaerts MF
    Thromb Haemost; 2007 Sep; 98(3):600-13. PubMed ID: 17849049
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibrated automated thrombin generation in frozen-thawed platelet-rich plasma to detect hypercoagulability.
    Regnault V; Béguin S; Lecompte T
    Pathophysiol Haemost Thromb; 2003; 33(1):23-9. PubMed ID: 12853709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thrombin generation in platelet-rich plasma as a tool for the detection of hypercoagulability in young stroke patients.
    Faber CG; Lodder J; Kessels F; Troost J
    Pathophysiol Haemost Thromb; 2003; 33(1):52-8. PubMed ID: 12853713
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Poor prognosis of hypocoagulability assessed by thrombin generation assay in disseminated intravascular coagulation.
    Lee K; Kim JE; Kwon J; Kim I; Yoon SS; Park S; Han KS; Kim HK
    Blood Coagul Fibrinolysis; 2014 Apr; 25(3):241-7. PubMed ID: 24675694
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibrated automated thrombogram II: removing barriers for thrombin generation measurements.
    Giesen PLA; Gulpen AJW; van Oerle R; Ten Cate H; Nagy M; Spronk HMH
    Thromb J; 2021 Aug; 19(1):60. PubMed ID: 34454531
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Differential effects of factor IIa inhibitors on the endogenous thrombin potential.
    Beilfuss A; Grandoch M; Wenzel F; Hohlfeld T; Schrör K; Weber AA
    Ther Drug Monit; 2008 Dec; 30(6):740-3. PubMed ID: 18824953
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Is there a place for thrombin generation assay in routine clinical laboratory?].
    Lecut C; Peters P; Massion PB; Gothot A
    Ann Biol Clin (Paris); 2015; 73(2):137-49. PubMed ID: 25847735
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Factors influencing thrombin generation measured as thrombin-antithrombin complexes levels and using calibrated automated thrombogram in patients with advanced coronary artery disease].
    Stepień E; Plicner D; Branicka A; Stankiewicz E; Pazdan A; Sniezek-Maciejewska M; Górkiewicz I; Kapelak B; Sadowski J
    Pol Arch Med Wewn; 2007 Jul; 117(7):297-305. PubMed ID: 17966595
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changing trends in anti-coagulant therapies. Are heparins and oral anti-coagulants challenged?
    Fareed J; Iqbal O; Cunanan J; Demir M; Wahi R; Clarke M; Adiguzel C; Bick R
    Int Angiol; 2008 Jun; 27(3):176-92. PubMed ID: 18506123
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hyper-coagulability in obese patients accurately identified by combinations of global coagulation assay parameters.
    Bertaggia Calderara D; Aliotta A; Zermatten MG; Kröll D; Stirnimann G; Alberio L
    Thromb Res; 2020 Mar; 187():91-102. PubMed ID: 31978812
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thrombin Generation in Fresh and Frozen-Thawed Platelet Poor Plasma - Is there a Difference?
    Kausche LE; Adler W; Zimmermann R; Hackstein H; Strasser EF
    Clin Lab; 2020 Jun; 66(6):. PubMed ID: 32538058
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of markers of coagulation activation and thrombin generation test in uncomplicated pregnancies.
    Joly B; Barbay V; Borg JY; Le Cam-Duchez V
    Thromb Res; 2013 Sep; 132(3):386-91. PubMed ID: 23962423
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.