These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

44 related articles for article (PubMed ID: 1368180)

  • 1. Use of modified polystyrene microwells to enhance immunoassay sensitivity.
    McLean L
    Am Biotechnol Lab; 1992 May; 10(5):58. PubMed ID: 1368180
    [No Abstract]   [Full Text] [Related]  

  • 2. Testing polystyrene microplates for coating uniformity.
    McLean L
    Am Biotechnol Lab; 1992 Dec; 10(12):22. PubMed ID: 1369031
    [No Abstract]   [Full Text] [Related]  

  • 3. Effectiveness of detergents in blocking nonspecific binding of IgG in the enzyme-linked immunosorbent assay (ELISA) depends upon the type of polystyrene used.
    Kenny GE; Dunsmoor CL
    Isr J Med Sci; 1987 Jun; 23(6):732-4. PubMed ID: 3667240
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the concept of heterology in a monoclonal antibody-based ELISA utilizing direct hapten linkage to polystyrene microtiter plates.
    Holthues H; Pfeifer-Fukumura U; Sound I; Baumann W
    J Immunol Methods; 2005 Sep; 304(1-2):68-77. PubMed ID: 16111698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preparation of Au coated polystyrene beads and their application in an immunoassay.
    Cao YC; Hua XF; Zhu XX; Wang Z; Huang ZL; Zhao YD; Chen H; Liu MX
    J Immunol Methods; 2006 Dec; 317(1-2):163-70. PubMed ID: 17107687
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of pretreatment of wells in polystyrene plates on adsorption of some human serum proteins.
    Kochanowska IE; Rapak A; Szewczuk A
    Arch Immunol Ther Exp (Warsz); 1994; 42(2):135-9. PubMed ID: 7503647
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of anti-ovalbumin IgG in serum by immune complex transfer enzyme immunoassay.
    Hirota K; Kamashima T; Totani M
    Clin Lab; 2001; 47(5-6):213-7. PubMed ID: 11405598
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The immunochemistry of solid-phase sandwich enzyme-linked immunosorbent assays.
    Butler JE; Peterman JH; Suter M; Dierks SE
    Fed Proc; 1987 Jun; 46(8):2548-56. PubMed ID: 3595892
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction of fibrinogen adsorption on PEG-coated polystyrene surfaces.
    Bergström K; Holmberg K; Safranj A; Hoffman AS; Edgell MJ; Kozlowski A; Hovanes BA; Harris JM
    J Biomed Mater Res; 1992 Jun; 26(6):779-90. PubMed ID: 1527100
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of adsorption and adhesion of proteins to polystyrene microwells by sequential enzyme-linked immunosorbent assay analysis.
    Stevens PW; Hansberry MR; Kelso DM
    Anal Biochem; 1995 Mar; 225(2):197-205. PubMed ID: 7762781
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay.
    Bai Y; Koh CG; Boreman M; Juang YJ; Tang IC; Lee LJ; Yang ST
    Langmuir; 2006 Oct; 22(22):9458-67. PubMed ID: 17042569
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of glass as solid phase in enzyme immunoassay as exemplified by the detection of circulating immune complexes.
    Schössler W; Hiepe F; Montag T; Schmidt HE
    Biomed Biochim Acta; 1985; 44(7-8):1247-53. PubMed ID: 3910036
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-performance microtiter plates for immunosorbent assays made of renewable resources: polylactic acid biopolymer as a substitute for synthetic polystyrene.
    Bouche FB; Schecklies E; Muller CP
    Clin Chem; 2002 Feb; 48(2):378-80. PubMed ID: 11805027
    [No Abstract]   [Full Text] [Related]  

  • 14. Enzyme-linked immunosorbent assay to quantify fibronectin.
    Gomez-Lechon MJ; Castell JV
    Anal Biochem; 1985 Feb; 145(1):1-8. PubMed ID: 4003752
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Establishment and validation of an immunoenzymatic assay to determine mouse IgG levels based on a rat monoclonal antibody.
    Díaz BR; Abrahantes-Pérez Mdel C; González M; Valdés R; Pérez ME
    Biochem Biophys Res Commun; 2004 Apr; 317(2):614-7. PubMed ID: 15063802
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Semiquantitative evaluation of fibronectin adsorption on unmodified and sulfonated polystyrene, as related to cell adhesion.
    Kowalczyńska HM; Nowak-Wyrzykowska M; Kołos R; Dobkowski J; Kamiński J
    J Biomed Mater Res A; 2008 Dec; 87(4):944-56. PubMed ID: 18228272
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Gold nanoparticle-based immunoassay by using non-stripping chemiluminescence detection.
    Duan CF; Yu YQ; Cui H
    Analyst; 2008 Sep; 133(9):1250-5. PubMed ID: 18709203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative studies on the interaction of proteins with a polydimethylsiloxane elastomer. II. The comparative antigenicity of primary and secondarily adsorbed IgG1 and IgG2a and their non-adsorbed counterparts.
    Butler JE; Navarro P; Lü EP
    J Mol Recognit; 1997; 10(1):52-62. PubMed ID: 9179779
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immune complex transfer enzyme immunoassay for anti-ovalbumin IgA in serum.
    Hirota K; Kamashima T; Hashida S; Totani M
    Ann Clin Biochem; 2002 Sep; 39(Pt 5):482-6. PubMed ID: 12227854
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An inverted microcontact printing method on topographically structured polystyrene chips for arrayed micro-3-D culturing of single cells.
    Dusseiller MR; Schlaepfer D; Koch M; Kroschewski R; Textor M
    Biomaterials; 2005 Oct; 26(29):5917-25. PubMed ID: 15949557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.