BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 1372416)

  • 21. Acute changes in pacing threshold and R- or P-wave amplitude during permanent pacemaker implantation.
    de Buitleir M; Kou WH; Schmaltz S; Morady F
    Am J Cardiol; 1990 Apr; 65(15):999-1003. PubMed ID: 2327362
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Assessment of long-term stability of chronic ventricular pacing thresholds in steroid-eluting electrodes.
    Stojanov P; Djordjević M; Velimirović D; Belkić K
    Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1417-20. PubMed ID: 1383950
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An algorithm for automatic measurement of stimulation thresholds: clinical performance and preliminary results.
    Danilovic D; Ohm OJ; Stroebel J; Breivik K; Hoff PI; Markowitz T
    Pacing Clin Electrophysiol; 1998 May; 21(5):1058-68. PubMed ID: 9604237
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical experience with an automatic threshold tracking algorithm study.
    Kennergren C; Larsson B; Uhrenius A; Gadler F;
    Pacing Clin Electrophysiol; 2003 Dec; 26(12):2219-24. PubMed ID: 14675003
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Initial clinical experience with a rate responsive pacemaker.
    Singer I; Olash J; Brennan AF; Kupersmith J
    Pacing Clin Electrophysiol; 1989 Sep; 12(9):1458-64. PubMed ID: 2476774
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Low settings of the ventricular pacing output in patients dependent on a pacemaker: are they really safe?
    Schuchert A; Frese J; Stammwitz E; Novák M; Schleich A; Wagner SM; Meinertz T
    Am Heart J; 2002 Jun; 143(6):1009-11. PubMed ID: 12075256
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Autocapture enhancements: unipolar and bipolar lead compatibility and bipolar pacing capability on bipolar leads.
    Binner L; Messenger J; Sperzel J; Bondke H; Vandekerckhove Y; Poore J; Scheiner J; Berkhof M; Park E; Holmström N; Bornzin GA
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):221-4. PubMed ID: 12687816
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pacing threshold trends and variability in modern tined leads assessed using high resolution automatic measurements: conversion of pulse width into voltage thresholds.
    Danilovic D; Ohm OJ
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):567-87. PubMed ID: 10234710
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Atrial evoked response integral for automatic capture verification in atrial pacing.
    Boriani G; Biffi M; Cameron D; Datteri S; Snell J; Holmström N; Park E; Bornzin GA
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):248-52. PubMed ID: 12687822
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Automatic management of atrial and ventricular stimulation in a contemporary unselected population of pacemaker recipients: the ESSENTIAL Registry.
    Biffi M; Bertini M; Saporito D; Belotti G; Quartieri F; Piancastelli M; Pucci A; Boggian G; Mazzocca GF; Giorgi D; Diotallevi P; Diemberger I; Martignani C; Pancaldi S; Ziacchi M; Marcantoni L; Toselli T; Attala S; Iori M; Bottoni N; Argnani S; Tomasi C; Sassone B; Boriani G
    Europace; 2016 Oct; 18(10):1551-1560. PubMed ID: 27305923
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers.
    Butter C; Hartung WM; Kay GN; Willems R; Zhang G; Lang DJ; Fleck E
    J Cardiovasc Electrophysiol; 2001 Oct; 12(10):1104-8. PubMed ID: 11699516
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Redundant pacing: case report and review.
    Morse DP; Tarjan P; McNicholas KW; DelRossi AJ; Lemole GM
    Pacing Clin Electrophysiol; 1984 Mar; 7(2):296-300. PubMed ID: 6200861
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Unexpected loss of bipolar pacing with implanted dual chamber pacemakers.
    Guo GB; Chen MC; Wang CC; Chang KC; Fu M
    Pacing Clin Electrophysiol; 2000 Jan; 23(1):4-7. PubMed ID: 10666747
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram.
    Feuer JM; Florio J; Shandling AH
    Pacing Clin Electrophysiol; 1990 Oct; 13(10):1254-60. PubMed ID: 1701540
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Italian experience with AutoCapture in conjunction with a membrane lead. Pacesetter Automatic Control of Energy and Membrane Automatic Threshold Evaluation (Pacemate) Study Group.
    Sermasi S; Marconi M; Libero L; Moracchini PV; Rusconi L; Mininno A; Sigliano R
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1799-804. PubMed ID: 8945044
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dynamic and dual-site atrial pacing in the prevention of atrial fibrillation: The STimolazione Atrial DInamica Multisito (STADIM) Study.
    De Simone A; Senatore G; Donnici G; Turco P; Romano E; Gazzola C; Stabile G
    Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S71-4. PubMed ID: 17302722
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electrocardiographic features of atrial depolarization during pacing of right atrial appendage.
    Pandit N; Sethi KK; Mohan JC; Arora R; Khalilullah M
    Indian Heart J; 1991; 43(2):79-82. PubMed ID: 1752619
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Atrial stimulation by means of floating electrodes: a multicenter experience. The Multicenter Study Group.
    Bongiorni MG; Bedendi N
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1977-81. PubMed ID: 1279583
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Acute effects of a class IA antiarrhythmic drug on the ventricular evoked response amplitude in patients with cardiac pacemakers.
    Schuchert A; Meinertz T
    Cardiology; 2000; 94(2):103-5. PubMed ID: 11173781
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pacing technology: advances in pacing threshold management.
    Lau CP; Siu CW
    J Zhejiang Univ Sci B; 2010 Aug; 11(8):634-8. PubMed ID: 20669355
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.