These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
179 related articles for article (PubMed ID: 1373393)
1. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Moatti-Sirat D; Capron F; Poitout V; Reach G; Bindra DS; Zhang Y; Wilson GS; Thévenot DR Diabetologia; 1992 Mar; 35(3):224-30. PubMed ID: 1373393 [TBL] [Abstract][Full Text] [Related]
2. A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Updike SJ; Shults MC; Gilligan BJ; Rhodes RK Diabetes Care; 2000 Feb; 23(2):208-14. PubMed ID: 10868833 [TBL] [Abstract][Full Text] [Related]
3. Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats. Woderer S; Henninger N; Garthe CD; Kloetzer HM; Hajnsek M; Kamecke U; Gretz N; Kraenzlin B; Pill J Anal Chim Acta; 2007 Jan; 581(1):7-12. PubMed ID: 17386418 [TBL] [Abstract][Full Text] [Related]
4. In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue. Johnson KW; Mastrototaro JJ; Howey DC; Brunelle RL; Burden-Brady PL; Bryan NA; Andrew CC; Rowe HM; Allen DJ; Noffke BW Biosens Bioelectron; 1992; 7(10):709-14. PubMed ID: 1292518 [TBL] [Abstract][Full Text] [Related]
5. Biocompatibility of an enzyme-based, electrochemical glucose sensor for short-term implantation in the subcutis. Kvist PH; Iburg T; Aalbaek B; Gerstenberg M; Schoier C; Kaastrup P; Buch-Rasmussen T; Hasselager E; Jensen HE Diabetes Technol Ther; 2006 Oct; 8(5):546-59. PubMed ID: 17037969 [TBL] [Abstract][Full Text] [Related]
6. A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Poitout V; Moatti-Sirat D; Reach G; Zhang Y; Wilson GS; Lemonnier F; Klein JC Diabetologia; 1993 Jul; 36(7):658-63. PubMed ID: 8359584 [TBL] [Abstract][Full Text] [Related]
7. Strategies for calibrating a subcutaneous glucose sensor. Velho G; Froguel P; Thevenot DR; Reach G Biomed Biochim Acta; 1989; 48(11-12):957-64. PubMed ID: 2700068 [TBL] [Abstract][Full Text] [Related]
8. Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man. Pickup JC; Claremont DJ; Shaw GW Acta Diabetol; 1993; 30(3):143-8. PubMed ID: 8111074 [TBL] [Abstract][Full Text] [Related]
9. Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Poitout V; Moatti-Sirat D; Reach G Biosens Bioelectron; 1992; 7(8):587-92. PubMed ID: 1457093 [TBL] [Abstract][Full Text] [Related]
10. Initial evaluation of a 290-microm diameter subcutaneous glucose sensor: glucose monitoring with a biocompatible, flexible-wire, enzyme-based amperometric microsensor in diabetic and nondiabetic humans. Ishikawa M; Schmidtke DW; Raskin P; Quinn CA J Diabetes Complications; 1998; 12(6):295-301. PubMed ID: 9877461 [TBL] [Abstract][Full Text] [Related]
11. Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo. Updike SJ; Shults MC; Rhodes RK; Gilligan BJ; Luebow JO; von Heimburg D ASAIO J; 1994; 40(2):157-63. PubMed ID: 8003752 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of subcutaneously-implanted glucose sensors for continuous glucose measurements in hyperglycemic pigs. Kvist PH; Bielecki M; Gerstenberg M; Rossmeisl C; Jensen HE; Rolin B; Hasselager E In Vivo; 2006; 20(2):195-203. PubMed ID: 16634519 [TBL] [Abstract][Full Text] [Related]
13. Defining the period of recovery of the glucose concentration after its local perturbation by the implantation of a miniature sensor. Chen T; Schmidtke DW; Heller A Clin Chem Lab Med; 2002 Aug; 40(8):786-9. PubMed ID: 12392305 [TBL] [Abstract][Full Text] [Related]
14. A needle-type glucose biosensor based on PANI nanofibers and PU/E-PU membrane for long-term invasive continuous monitoring. Fang L; Liang B; Yang G; Hu Y; Zhu Q; Ye X Biosens Bioelectron; 2017 Nov; 97():196-202. PubMed ID: 28599179 [TBL] [Abstract][Full Text] [Related]
15. In vivo performance evaluation of a transdermal near- infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring. Ballerstadt R; Evans C; Gowda A; McNichols R Diabetes Technol Ther; 2006 Jun; 8(3):296-311. PubMed ID: 16800751 [TBL] [Abstract][Full Text] [Related]
16. A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm. Aussedat B; Thomé-Duret V; Reach G; Lemmonier F; Klein JC; Hu Y; Wilson GS Biosens Bioelectron; 1997; 12(11):1061-71. PubMed ID: 9451795 [TBL] [Abstract][Full Text] [Related]
17. Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man. Moatti-Sirat D; Poitout V; Thomé V; Gangnerau MN; Zhang Y; Hu Y; Wilson GS; Lemonnier F; Klein JC; Reach G Diabetologia; 1994 Jun; 37(6):610-6. PubMed ID: 7926347 [TBL] [Abstract][Full Text] [Related]
18. Assessment of chronically implanted subcutaneous glucose sensors in dogs: the effect of surrounding fluid masses. Ward WK; Troupe JE ASAIO J; 1999; 45(6):555-61. PubMed ID: 10593686 [TBL] [Abstract][Full Text] [Related]
19. In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor. Poitout V; Moatti D; Velho G; Reach G; Sternberg R; Thévenot DR; Bindra DS; Zhang YN; Wilson GS ASAIO Trans; 1991; 37(3):M298-300. PubMed ID: 1751159 [TBL] [Abstract][Full Text] [Related]
20. Lifespan of subcutaneous glucose sensors and their performances during dynamic glycaemia changes in rats. Bobbioni-Harsch E; Rohner-Jeanrenaud F; Koudelka M; de Rooij N; Jeanrenaud B J Biomed Eng; 1993 Nov; 15(6):457-63. PubMed ID: 8277748 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]