These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 1373393)

  • 21. Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration.
    Schmidtke DW; Heller A
    Anal Chem; 1998 May; 70(10):2149-55. PubMed ID: 9608851
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating.
    Moussy F; Harrison DJ; O'Brien DW; Rajotte RV
    Anal Chem; 1993 Aug; 65(15):2072-7. PubMed ID: 8372970
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients.
    Hashiguchi Y; Sakakida M; Nishida K; Uemura T; Kajiwara K; Shichiri M
    Diabetes Care; 1994 May; 17(5):387-96. PubMed ID: 8062605
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Performance of subcutaneously implanted glucose sensors: a review.
    Gerritsen M; Jansen JA; Kros A; Nolte RJ; Lutterman JA
    J Invest Surg; 1998; 11(3):163-74. PubMed ID: 9743484
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Strategies for testing long-term transcutaneous amperometric glucose sensors.
    Long N; Yu B; Moussy Y; Moussy F
    Diabetes Technol Ther; 2005 Dec; 7(6):927-36. PubMed ID: 16386099
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A needle-type sensor for monitoring glucose in whole blood.
    Yang Q; Atanasov P; Wilkins E
    Biomed Instrum Technol; 1997; 31(1):54-62. PubMed ID: 9051226
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell.
    Abel P; Müller A; Fischer U
    Biomed Biochim Acta; 1984; 43(5):577-84. PubMed ID: 6477543
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Continuous monitoring of glucose in subcutaneous tissue using microfabricated differential affinity sensors.
    Huang X; Leduc C; Ravussin Y; Li S; Davis E; Song B; Wang Q; Accili D; Leibel R; Lin Q
    J Diabetes Sci Technol; 2012 Nov; 6(6):1436-44. PubMed ID: 23294791
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Recording of subcutaneous glucose dynamics by a viscometric affinity sensor.
    Beyer U; Schäfer D; Thomas A; Aulich H; Haueter U; Reihl B; Ehwald R
    Diabetologia; 2001 Apr; 44(4):416-23. PubMed ID: 11357470
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model.
    Gilligan BJ; Shults MC; Rhodes RK; Updike SJ
    Diabetes Care; 1994 Aug; 17(8):882-7. PubMed ID: 7956636
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tissue response to subcutaneous implantation of glucose-oxidase-based glucose sensors in rats.
    Henninger N; Woderer S; Kloetzer HM; Staib A; Gillen R; Li L; Yu X; Gretz N; Kraenzlin B; Pill J
    Biosens Bioelectron; 2007 Aug; 23(1):26-34. PubMed ID: 17467971
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs.
    Moussy F; Harrison DJ; Rajotte RV
    Int J Artif Organs; 1994 Feb; 17(2):88-94. PubMed ID: 8039946
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Microdialysis-coupled enzymatic microreactor for in vivo glucose monitoring in rats.
    Moon BU; de Vries MG; Cordeiro CA; Westerink BH; Verpoorte E
    Anal Chem; 2013 Nov; 85(22):10949-55. PubMed ID: 24199633
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vivo response of microfabricated glucose sensors to glycemia changes in normal rats.
    Koudelka M; Rohner-Jeanrenaud F; Terrettaz J; Bobbioni-Harsch E; de Rooij NF; Jeanrenaud B
    Biomed Biochim Acta; 1989; 48(11-12):953-6. PubMed ID: 2636840
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In situ calibration of implanted electrochemical glucose sensors.
    von Woedtke T; Rebrin K; Fischer U; Abel P; Wilke W; Vogt L; Albrecht G
    Biomed Biochim Acta; 1989; 48(11-12):943-52. PubMed ID: 2636839
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors.
    Ertefai S; Gough DA
    J Biomed Eng; 1989 Sep; 11(5):362-8. PubMed ID: 2677523
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane.
    Yu B; Long N; Moussy Y; Moussy F
    Biosens Bioelectron; 2006 Jun; 21(12):2275-82. PubMed ID: 16330201
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation.
    Ward WK; Jansen LB; Anderson E; Reach G; Klein JC; Wilson GS
    Biosens Bioelectron; 2002 Mar; 17(3):181-9. PubMed ID: 11839471
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vivo characteristics of needle-type glucose sensor--measurements of subcutaneous glucose concentrations in human volunteers.
    Shichiri M; Yamasaki Y; Nao K; Sekiya M; Ueda N
    Horm Metab Res Suppl; 1988; 20():17-20. PubMed ID: 3248784
    [TBL] [Abstract][Full Text] [Related]  

  • 40. In-vivo behaviour of hypodermically implanted microfabricated glucose sensors.
    Koudelka M; Rohner-Jeanrenaud F; Terrettaz J; Bobbioni-Harsch E; de Rooij NF; Jeanrenaud B
    Biosens Bioelectron; 1991; 6(1):31-6. PubMed ID: 2049169
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.