These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 1378607)

  • 21. Programming a long paced atrioventricular interval may be risky in DDDR pacing.
    Pieterse MG; den Dulk K; van Gelder BM; van Mechelen R; Wellens HJ
    Pacing Clin Electrophysiol; 1994 Feb; 17(2):252-7. PubMed ID: 7513413
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measurements of cardiac output by impedance cardiography in pacemaker patients at rest: effects of various atrioventricular delays.
    Ovsyshcher I; Zimlichman R; Katz A; Bondy C; Furman S
    J Am Coll Cardiol; 1993 Mar; 21(3):761-7. PubMed ID: 8436759
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Responses of an AV universal (DDD) pulse generator (Cordis 233D) to programmed single ventricular extrastimuli.
    van Mechelen R; Hagemeijer F; de Jong J; de Boer H
    Pacing Clin Electrophysiol; 1984 Mar; 7(2):215-26. PubMed ID: 6200846
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Far-field R wave sensing causing prolongation of the atrial escape interval of DDD pacemakers with atrial-based lower rate timing.
    Barold SS
    Pacing Clin Electrophysiol; 2003 Nov; 26(11):2188-91. PubMed ID: 14622327
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The hemodynamic benefit of differential atrioventricular delay intervals for sensed and paced atrial events during physiologic pacing.
    Janosik DL; Pearson AC; Buckingham TA; Labovitz AJ; Redd RM
    J Am Coll Cardiol; 1989 Aug; 14(2):499-507. PubMed ID: 2754135
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Atrial rate and increased work capacity during DDD pacing in patients with a high level atrioventricular block].
    Doupal V; Lukl J; Heinc P
    Cor Vasa; 1993; 35(4):152-6. PubMed ID: 8403940
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Suppression of ventricular output by noise in the atrial channel in a dual chamber pacemaker.
    Ben-Zur UM; Kahn S; Gross JN; Platt SB; Goodfriend MA; Furman S
    Pacing Clin Electrophysiol; 1995 Aug; 18(8):1586-8. PubMed ID: 7479181
    [TBL] [Abstract][Full Text] [Related]  

  • 28. VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.
    Naegeli B; Osswald S; Pfisterer M; Burkart F
    Pacing Clin Electrophysiol; 1996 Apr; 19(4 Pt 1):455-64. PubMed ID: 8848393
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [The effect of changes in stroke volume on QT dispersion during long-term DDD and VVI pacing].
    Lelakowski J; Majewski J; Bednarek J; Szczepkowski J; Machejek J
    Przegl Lek; 2001; 58(3):111-6. PubMed ID: 11475854
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Modification of the DDD pacing mode to prevent junctional reentry tachycardia: computer modelling experiments.
    Malik M; Davies DW; Camm AJ
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1465-78. PubMed ID: 2462224
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of atrioventricular sequential pacing in patients with no ventriculoatrial conduction.
    Mahmud R; Denker S; Lehmann MH; Akhtar M
    J Am Coll Cardiol; 1984 Aug; 4(2):273-7. PubMed ID: 6736468
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A case of a pseudomalfunction of a DDD pacemaker.
    Ajiki K; Sagara K; Namiki T; Ishibashi H; Iinuma H; Fu LT; Kato K
    Pacing Clin Electrophysiol; 1991 Oct; 14(10):1456-60. PubMed ID: 1721126
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Behavior of the ventricular triggering period of DDD pacemakers.
    Barold SS; Belott PH
    Pacing Clin Electrophysiol; 1987 Nov; 10(6):1237-52. PubMed ID: 2446271
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Use of automatic mode change between DDD and AAI to facilitate native atrioventricular conduction in patients with sick sinus syndrome or transient atrioventricular block.
    Mayumi H; Kohno H; Yasui H; Kawachi Y; Tokunaga K
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1740-7. PubMed ID: 8945033
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Chronic steroid-eluting lead performance: a comparison of atrial and ventricular pacing.
    Hua W; Mond HG; Strathmore N
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):17-24. PubMed ID: 9121966
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Randomized pilot study of a new atrial-based minimal ventricular pacing mode in dual-chamber implantable cardioverter-defibrillators.
    Sweeney MO; Shea JB; Fox V; Adler S; Nelson L; Mullen TJ; Belk P; Casavant D; Sheldon T
    Heart Rhythm; 2004 Jul; 1(2):160-7. PubMed ID: 15851147
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [DDD versus DDDR pacemaker stimulation: comparison of cardiopulmonary performance, incidence of atrial arrhythmias and quality of life].
    Epperlein S; Kreft A; Siegert V; Liebrich A; Himmrich E; Treese N
    Z Kardiol; 1996 Apr; 85(4):226-36. PubMed ID: 8693765
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ventricular output failure in a DDD permanent pacemaker associated with increased atrial output.
    Santucci PA; Mitra RL
    Pacing Clin Electrophysiol; 1997 Nov; 20(11):2860-3. PubMed ID: 9392819
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pure atrial-based lower rate timing of dual chamber pacemakers: implications for upper rate limitation.
    Barold SS; Fredman CS
    Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 1):391-400. PubMed ID: 7770358
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intermittent P wave sensing in a patient with DDD pacemaker.
    Paraskevaidis S; Mochlas S; Hadjimiltiadis S; Louridas G
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):689-90. PubMed ID: 10234728
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.