These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 1378607)

  • 41. Early clinical experience with a minute ventilation sensor DDDR pacemaker.
    Vanerio G; Patel S; Ching E; Trohman RG; Wilkoff BL; Castle LW; Maloney JD; Simmons TW
    Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 2):1815-20. PubMed ID: 1721181
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A randomized study on the effects of pacemaker programming to a lower output on projected pulse generator longevity.
    Schuchert A; Meinertz T;
    Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1234-9. PubMed ID: 11523609
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers.
    Lau CP; Tai YT; Fong PC; Li JP; Chung FL
    Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1504-14. PubMed ID: 1383962
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Comparative evaluation of various methods of continuous electric stimulation of the heart in bradycardia].
    Drogaĭtsev AD
    Kardiologiia; 1990 Feb; 30(2):5-11. PubMed ID: 2348620
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Changes in QT and Q-aT intervals induced by mental and physical stress with fixed rate and atrial triggered ventricular inhibited cardiac pacing.
    Hedman A; Nordlander R
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1426-31. PubMed ID: 2462219
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Magnet unresponsive pacemaker endless loop tachycardia.
    Barold SS; Falkoff MD; Ong LS; Heinle RA
    Am Heart J; 1988 Sep; 116(3):726-32. PubMed ID: 3414488
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A new approach to the prevention of endless loop tachycardia in DDD and VVD pacing.
    Rognoni G; Occhetta E; Perucca A; Magnani A; Francalacci G; Audoglio R; Rossi P
    Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 2):1828-34. PubMed ID: 1721183
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Complications of single lead VDD pacing in 35 patients with AV block.
    Parravicini U; Zanetta M; Zenone F; Bielli M
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1901-2. PubMed ID: 1279568
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Benefits and limits of single chamber atrial pacing with adaptive rate].
    Pouillot C; Mabo P; Lelong B; Cazeau S; Paillard F; de Place C; Daubert JC
    Arch Mal Coeur Vaiss; 1990 Nov; 83(12):1833-42. PubMed ID: 2125194
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Development of atrial fibrillation in patients with atrioventricular block after atrioventricular synchronized pacing.
    Kong CW; Yu WC; Chen SA; Lin YJ; Huang CY; Chung SL
    Pacing Clin Electrophysiol; 2004 Mar; 27(3):352-7. PubMed ID: 15009862
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Adverse pacemaker hemodynamics evaluated by pulmonary venous flow monitoring.
    Stierle U; Krüger D; Mitusch R; Potratz J; Taubert G; Sheikhzadeh A
    Pacing Clin Electrophysiol; 1995 Nov; 18(11):2028-34. PubMed ID: 8552517
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Dual chamber pacing: how many patients remain in DDD mode over the long term?
    Ibrahim B; Sanderson JE; Wright B; Palmer R
    Br Heart J; 1995 Jul; 74(1):76-9. PubMed ID: 7662461
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Evaluation of atrial conduction time at various sites of right atrial pacing and influence on atrioventricular delay optimization by surface electrocardiography.
    Strohmer B; Pichler M; Froemmel M; Migschitz M; Hintringer F;
    Pacing Clin Electrophysiol; 2004 Apr; 27(4):468-74. PubMed ID: 15078399
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Atrial synchronous ventricular inhibited pacing (VDD): an underutilized mode of pacing.
    Messenger JC; Greenberg PS; Warren J; Castellanet MJ
    Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):392-8. PubMed ID: 6189084
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Tachycardia mediated by an AV universal (DDD) pacemaker triggered by a ventricular depolarization.
    Pimenta J; Soldá R; Pereira CB
    Pacing Clin Electrophysiol; 1986 Jan; 9(1 Pt 1):105-7. PubMed ID: 2419839
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The superfast atrial recharge pulse: a cause of pectoral muscle stimulation in patients equipped with a unipolar DDD pacemaker.
    Stroobandt R; Willems R; Depuydt P; Holvoet G; Sinnaeve A
    Pacing Clin Electrophysiol; 1989 Mar; 12(3):451-5. PubMed ID: 2466271
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Hemodynamic effect of physiological dual chamber pacing in a patient with end-stage dilated cardiomyopathy: a case report.
    Kataoka H
    Pacing Clin Electrophysiol; 1991 Sep; 14(9):1330-5. PubMed ID: 1720525
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Heart rate variability in patients suffering from structural heart disease and decreased AV-nodal conduction capacity. Insights into the formation of heart rate variability.
    Schwab JO; Eichner G; Schmitt H; Schrickel J; Yang A; Balta O; Lüderitz B; Lewalter T
    Z Kardiol; 2004 Mar; 93(3):229-33. PubMed ID: 15024591
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Atrial tracking (synchronous) pacing in a pediatric and young adult population.
    Gillette PC; Zinner A; Kratz J; Shannon C; Wampler D; Ott D
    J Am Coll Cardiol; 1987 Apr; 9(4):811-5. PubMed ID: 3558979
    [TBL] [Abstract][Full Text] [Related]  

  • 60. What range of programmable AV delays is necessary in antibradycardia DDD stimulation?
    Von Knorre GH; Ismer B; Voss W; Petzsch M; Pulya K
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 2):264-7. PubMed ID: 9474685
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.