BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 1389281)

  • 41. Reduction in blood loss and blood use after cardiopulmonary bypass with high dose aprotinin (Trasylol).
    Bidstrup BP; Royston D; Sapsford RN; Taylor KM
    J Thorac Cardiovasc Surg; 1989 Mar; 97(3):364-72. PubMed ID: 2465457
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Centrifugal and roller pumps--are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass?
    Steinbrueckner BE; Steigerwald U; Keller F; Neukam K; Elert O; Babin-Ebell J
    Heart Vessels; 1995; 10(1):46-53. PubMed ID: 7730247
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, nonocclusive roller pumps and centrifugal pumps.
    Hansbro SD; Sharpe DA; Catchpole R; Welsh KR; Munsch CM; McGoldrick JP; Kay PH
    Perfusion; 1999 Jan; 14(1):3-10. PubMed ID: 10074641
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Less platelet damage in the curved vane centrifugal pump: a comparative study with the roller pump in open heart surgery.
    Nishinaka T; Nishida H; Endo M; Koyanagi H
    Artif Organs; 1994 Sep; 18(9):687-90. PubMed ID: 7998887
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation.
    Fromes Y; Gaillard D; Ponzio O; Chauffert M; Gerhardt MF; Deleuze P; Bical OM
    Eur J Cardiothorac Surg; 2002 Oct; 22(4):527-33. PubMed ID: 12297167
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Heparin-coated cardiopulmonary bypass circuits: hemostatic alterations and postoperative blood loss.
    Wagner WR; Johnson PC; Thompson KA; Marrone GC
    Ann Thorac Surg; 1994 Sep; 58(3):734-40; discussion 741. PubMed ID: 7944696
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Clinical and biomaterial evaluation of a new condensed dual-function extracorporeal circuit in reoperation for coronary artery bypass surgery.
    Gunaydin S; McCusker K; Vijay V
    Int J Artif Organs; 2009 Nov; 32(11):802-10. PubMed ID: 20020412
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparison of two different minimized extracorporeal circulation systems: hematological effects after coronary surgery.
    Haneya A; Philipp A; Diez C; Ried M; Puehler T; Camboni D; Zausig Y; Lehle K; Schmid C
    ASAIO J; 2009; 55(6):592-7. PubMed ID: 19812477
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Effects of centrifugal and roller pumps on survival of autologous red cells in cardiopulmonary bypass surgery.
    Valeri CR; MacGregor H; Ragno G; Healey N; Fonger J; Khuri SF
    Perfusion; 2006 Dec; 21(5):291-6. PubMed ID: 17201084
    [TBL] [Abstract][Full Text] [Related]  

  • 50. No clear clinical benefit of using mini-invasive extracorporeal circulation in coronary artery bypass grafting in low-risk patients.
    Svitek V; Lonsky V; Mandak J; Krejsek J; Kolackova M; Brzek V; Kubicek J; Volt M; Bartos M; Harrer J
    Perfusion; 2009 Nov; 24(6):389-95. PubMed ID: 20093333
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Comparison of the standard roller pump and a pulsatile centrifugal pump for extracorporeal circulation during routine coronary artery bypass grafting.
    Driessen JJ; Fransen G; Rondelez L; Schelstraete E; Gevaert L
    Perfusion; 1991; 6(4):303-11. PubMed ID: 10171162
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A randomised controlled trial of roller versus centrifugal cardiopulmonary bypass pumps in patients undergoing pulmonary endarterectomy.
    Mlejnsky F; Klein AA; Lindner J; Maruna P; Kvasnicka J; Kvasnicka T; Zima T; Pecha O; Lips M; Rulisek J; Porizka M; Kopecky P; Kunstyr J
    Perfusion; 2015 Oct; 30(7):520-8. PubMed ID: 25258197
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Clinical experience with Nikkiso centrifugal pumps for extracorporeal circulation.
    Onoda K; Kondo C; Mizumoto T; Kusagawa H; Katayama Y; Hayashi T; Komada T; Hirano R; Miyamura T; Tanaka J
    Artif Organs; 1994 Sep; 18(9):706-10. PubMed ID: 7998891
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The Impact of Roller Pump vs. Centrifugal Pump on Homologous Blood Transfusion in Pediatric Cardiac Surgery.
    Datt B; Nguyen MB; Plancher G; Ruzmetov M; O'Brien M; Kube A; Munro HM; Pourmoghadam KK; DeCampli WM
    J Extra Corpor Technol; 2017 Mar; 49(1):36-43. PubMed ID: 28298664
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Clinical study of totally roller pumpless cardiopulmonary bypass system.
    Murakami F; Usui A; Hiroura M; Kawamura M; Koyama T; Murase M
    Artif Organs; 1997 Jul; 21(7):803-7. PubMed ID: 9212963
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Reduced release of tissue factor by application of a centrifugal pump during cardiopulmonary bypass.
    Babin-Ebell J; Misoph M; Müllges W; Neukam K; Elert O
    Heart Vessels; 1998; 13(3):147-51. PubMed ID: 10328185
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Proinflammatory mediator response in coronary bypass surgery using a centrifugal or a roller pump.
    Sao M; Perttilä J; Pulkki K; Grönroos J; Mertsola J; Peltola O; Nevalainen T
    J Extra Corpor Technol; 1995 Sep; 27(3):146-51. PubMed ID: 10155359
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Development of the Terumo Capiox centrifugal pump and its clinical application to open heart surgery: a comparative study with the roller pump.
    Nishida H; Yamaki F; Nakatani H; Endo M; Koyanagi H; Oshiyama H; Horiuchi K; Kijima T; Nojiri C; Fukasawa H
    Artif Organs; 1993 May; 17(5):323-7. PubMed ID: 8507167
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Inflammatory mediators in adults undergoing cardiopulmonary bypass: comparison of centrifugal and roller pumps.
    Ashraf S; Butler J; Tian Y; Cowan D; Lintin S; Saunders NR; Watterson KG; Martin PG
    Ann Thorac Surg; 1998 Feb; 65(2):480-4. PubMed ID: 9485250
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Jostra Rota Flow RF-30 pump system: a new centrifugal blood pump for cardiopulmonary bypass.
    Orime Y; Shiono M; Yagi S; Yamamoto T; Okumura H; Nakata K; Kimura S; Hata M; Sezai A; Kashiwazaki S; Choh S; Negishi N; Sezai Y; Matsui T; Suzuki M
    Artif Organs; 2000 Jun; 24(6):437-41. PubMed ID: 10886061
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.