115 related articles for article (PubMed ID: 1392256)
1. Computer-controlled flow simulator for MR flow studies.
Frayne R; Holdsworth DW; Gowman LM; Rickey DW; Drangova M; Fenster A; Rutt BK
J Magn Reson Imaging; 1992; 2(5):605-12. PubMed ID: 1392256
[TBL] [Abstract][Full Text] [Related]
2. Comparison of velocity-encoded MR imaging and fluid dynamic modeling of steady and disturbed flow.
Sun Y; Hearshen DO; Rankin GW; Haggar AM
J Magn Reson Imaging; 1992; 2(4):443-52. PubMed ID: 1633398
[TBL] [Abstract][Full Text] [Related]
3. Blood flow imaging through detection of temporal variations in magnetization.
Wolf RL; Richardson DB; LaPlante CC; Huston J; Riederer SJ; Ehman RL
Radiology; 1992 Nov; 185(2):559-67. PubMed ID: 1410373
[TBL] [Abstract][Full Text] [Related]
4. Improving geometric model construction for blood flow modeling.
Wang KC; Dutton RW; Taylor CA
IEEE Eng Med Biol Mag; 1999; 18(6):33-9. PubMed ID: 10576070
[No Abstract] [Full Text] [Related]
5. An MR compatible flow simulator for intravascular pressure simulation.
Plewes DB; Urchuk SN; Kim S; Soutar I
Med Phys; 1995 Jul; 22(7):1111-5. PubMed ID: 7565386
[TBL] [Abstract][Full Text] [Related]
6. Flush-mounted hot film anemometer accuracy in pulsatile flow.
Nandy S; Tarbell JM
J Biomech Eng; 1986 Aug; 108(3):228-31. PubMed ID: 2943937
[TBL] [Abstract][Full Text] [Related]
7. Visualization and quantification of the human blood flow by magnetic resonance imaging.
Boesiger P; Maier SE; Kecheng L; Scheidegger MB; Meier D
J Biomech; 1992 Jan; 25(1):55-67. PubMed ID: 1733984
[TBL] [Abstract][Full Text] [Related]
8. MR angiography without subtraction.
Zur Y; Zou X; Neuringer LJ
Magn Reson Med; 1991 Jun; 19(2):361-72. PubMed ID: 1881326
[TBL] [Abstract][Full Text] [Related]
9. Flow-independent magnetic resonance projection angiography.
Wright GA; Nishimura DG; Macovski A
Magn Reson Med; 1991 Jan; 17(1):126-40. PubMed ID: 2067389
[TBL] [Abstract][Full Text] [Related]
10. Computer-assisted modeling of blood-flow: theoretical evidence for the existence of optimal flow wave patterns.
Schwartz LB; Purut CM; Craig DM; Smith PK; McCann RL
Comput Biol Med; 1993 Mar; 23(2):83-93. PubMed ID: 8513669
[TBL] [Abstract][Full Text] [Related]
11. A flexible blood flow phantom capable of independently producing constant and pulsatile flow with a predictable spatial flow profile for ultrasound flow measurement validations.
Hein IA; O'Brien WD
IEEE Trans Biomed Eng; 1992 Nov; 39(11):1111-22. PubMed ID: 1487274
[TBL] [Abstract][Full Text] [Related]
12. Turbine flow sensor for volume-flow rate verification in MR.
Frayne R; Holdsworth DW; Smith RF; Kasrai R; Larsen JP; Rutt BK
Magn Reson Med; 1994 Sep; 32(3):410-7. PubMed ID: 7984075
[TBL] [Abstract][Full Text] [Related]
13. Description of flow phenomena in magnetic resonance imaging.
Deimling M; Mueller E; Lenz G; Barth K; Fritschy P; Seiderer M; Reinhardt ER
Diagn Imaging Clin Med; 1986; 55(1-2):37-51. PubMed ID: 3635444
[TBL] [Abstract][Full Text] [Related]
14. [The numerical simulation of pulsatile flow in a tapered blood vessel].
Qiu L; Fan Y; Dong B; Yuan Z
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Aug; 21(4):558-61. PubMed ID: 15357431
[TBL] [Abstract][Full Text] [Related]
15. Disturbed flow in models of branching vessels.
Karino T; Goldsmith HL
Trans Am Soc Artif Intern Organs; 1980; 26():500-6. PubMed ID: 7245540
[No Abstract] [Full Text] [Related]
16. Development of a flow simulator to study haemodynamic behaviour of natural and artificial blood vessels under physiologic flow conditions.
Charara J; Ruel J; Lemay J; Doillon CJ
J Med Eng Technol; 1999; 23(3):83-95. PubMed ID: 10425607
[TBL] [Abstract][Full Text] [Related]
17. Time-of-flight MR angiography.
Nishimura DG
Magn Reson Med; 1990 May; 14(2):194-201. PubMed ID: 2345502
[TBL] [Abstract][Full Text] [Related]
18. Real time blood flow imaging by spiral scan phase velocity mapping.
Gatehouse PD; Firmin DN; Collins S; Longmore DB
Magn Reson Med; 1994 May; 31(5):504-12. PubMed ID: 8015403
[TBL] [Abstract][Full Text] [Related]
19. A model of pulsatile flow in a uniform deformable vessel.
Johnson GA; Borovetz HS; Anderson JL
J Biomech; 1992 Jan; 25(1):91-100. PubMed ID: 1733987
[TBL] [Abstract][Full Text] [Related]
20. The effects of fluid-mechanical factors on MR imaging in the arterial model.
Allgayer B; Liepsch D; Lukas P; Deimling M; Rupp N; Reiser M
Eur J Radiol; 1985 Aug; 5(3):231-5. PubMed ID: 4029162
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]