These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 13923260)

  • 1. A rapid manometric method for the analysis of carbon dioxide in serum.
    TURPIN FH; ROBERTS BL
    Am J Med Technol; 1962; 28():217-22. PubMed ID: 13923260
    [No Abstract]   [Full Text] [Related]  

  • 2. Carbon dioxide and oxygen determinations using the Van Slyke-Neill manometric apparatus.
    BROWNHILL LE
    Am J Med Technol; 1956; 22(3):159-66. PubMed ID: 13313558
    [No Abstract]   [Full Text] [Related]  

  • 3. The manometric analysis of respiratory gases in blood containing volatile anesthetic agents. I. A comparison of macromethods.
    HOLADAY DA; VEROSKY M
    J Lab Clin Med; 1955 Jan; 45(1):149-52. PubMed ID: 13233641
    [No Abstract]   [Full Text] [Related]  

  • 4. An improved type of apparatus for manometric microdetermination of CO2 in small volumes of plasma or serum.
    EICHHORN F; NUTMAN M; RAPPAPORT F
    Clin Chim Acta; 1956; 1(4):305-10. PubMed ID: 13374865
    [No Abstract]   [Full Text] [Related]  

  • 5. NEW MANOMETRIC APPARATUS AND TECHNIQUE FOR SEMI-MICRO SERUM CO2 AND BLOOD UREA DETERMINATIONS.
    AFONSO E
    Clin Chim Acta; 1964 Feb; 9():173-8. PubMed ID: 14122506
    [No Abstract]   [Full Text] [Related]  

  • 6. A rapid electrochemical technic for measuring carbon dioxide content of blood.
    Reyes RJ; Neville JR
    Clin Chem; 1968 Jul; 14(7):637-45. PubMed ID: 5663460
    [No Abstract]   [Full Text] [Related]  

  • 7. High-pressure carbon dioxide uptake for porous organic cages: comparison of spectroscopic and manometric measurement techniques.
    Hasell T; Armstrong JA; Jelfs KE; Tay FH; Thomas KM; Kazarian SG; Cooper AI
    Chem Commun (Camb); 2013 Oct; 49(82):9410-2. PubMed ID: 24013272
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Laparoscopic transcystic sphincter of Oddi manometry is not affected by carbon dioxide pneumoperitoneum.
    Kligman MD; Madden M; Arregui ME
    Surg Laparosc Endosc Percutan Tech; 2001 Jun; 11(3):185-8. PubMed ID: 11444749
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A BLOODLESS METHOD IN THE DETERMINATION OF PARTIAL CARBON DIOXIDE PRESSURE IN MIXED VENOUS AND ARTERIAL BLOOD].
    PUDELSKI J
    Gruzlica (1926); 1963 Sep; 31():965-72. PubMed ID: 14121096
    [No Abstract]   [Full Text] [Related]  

  • 10. [New manometric 2-vessel method].
    Warburg O
    Hoppe Seylers Z Physiol Chem; 1967 Dec; 348(12):1677-82. PubMed ID: 5586913
    [No Abstract]   [Full Text] [Related]  

  • 11. Automatic pipeting attachment for the Van Slyke manometric apparatus for CO2 determination.
    SELIGSON D; MARINO J
    Clin Chem; 1958 Apr; 4(2):120-6. PubMed ID: 13523871
    [No Abstract]   [Full Text] [Related]  

  • 12. [Measurements of hydrogen-ion concentration, carbon dioxide partial pressure and bicarbonates using the Van Slyke gasometer].
    Montgrain C
    Med Lab (Stuttg); 1968 Feb; 21(2):43-7. PubMed ID: 5715689
    [No Abstract]   [Full Text] [Related]  

  • 13. [The examination of hypercapnia. Experience from the correlation of results of some laboratory technics].
    Stiksa J; Daum S; Plachá B
    Cas Lek Cesk; 1966 Jul; 105(26):699-701. PubMed ID: 5956980
    [No Abstract]   [Full Text] [Related]  

  • 14. Bimodal distribution in venous carbon dioxide content in healthy subjects.
    Kost GJ; Fraser DR; Drummer JM
    Clin Chem; 1987 Aug; 33(8):1473-4. PubMed ID: 3111755
    [No Abstract]   [Full Text] [Related]  

  • 15. CAMPBELL AND HOWELL'S METHOD OF ESTIMATING THE CARBON DIOXIDE TENSION IN ARTERIAL AND MIXED VENOUS BLOOD.
    FROSTAD S; FROSTAD E
    Scand J Clin Lab Invest; 1964; 16():192-4. PubMed ID: 14161855
    [No Abstract]   [Full Text] [Related]  

  • 16. Bone CO2-titration curves in acute hypercapnia obtained with a modified titration technique.
    Pasquale SM; Messier AA; Shea ML; Schaefer KE
    J Appl Physiol Respir Environ Exerc Physiol; 1980 Jan; 48(1):197-201. PubMed ID: 7353973
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A rapid method for the simultaneous equilibration of large numbers of specimens of serum with carbon dioxide.
    BARBER D; SCANLON LJ
    Am J Clin Pathol; 1961 Oct; 36():333-5. PubMed ID: 13864830
    [No Abstract]   [Full Text] [Related]  

  • 18. Oxygen and CO-2 content in the splanchnic and nonsplanchnic blood of dogs with portacaval transposition.
    Herrmann TJ; Taylor PD; Marchioro TL; Starzl TE
    Surgery; 1966 Dec; 60(6):1229-31. PubMed ID: 5926542
    [No Abstract]   [Full Text] [Related]  

  • 19. DETERMINATION OF CARBON DIOXIDE TENSION OF WHOLE BLOOD BY PH MEASUREMENTS AND INTERPOLATION.
    BERGLUND E; MALMBERG R; STENHAGEN S
    Scand J Clin Lab Invest; 1964; 16():185-91. PubMed ID: 14161854
    [No Abstract]   [Full Text] [Related]  

  • 20. Gastric tonometry--quo vadis?
    Morgan TJ; Venkatesh B; Lipman J
    S Afr J Surg; 1997 May; 35(2):51-2. PubMed ID: 9267169
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.