These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 13947)

  • 1. New techniques for ion-selective measurement of Ca2+ in serum after pH adjustment of aerobically handled sera.
    Fuchs C; McIntosh C
    Clin Chem; 1977 Mar; 23(3):610-1. PubMed ID: 13947
    [No Abstract]   [Full Text] [Related]  

  • 2. New techniques for ion-selective measurements of ionized calcium in serum after pH adjustment of aerobically handled sera.
    Schwartz HD
    Clin Chem; 1976 Apr; 22(4):461-7. PubMed ID: 3297
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of free calcium ion in capillary blood and serum.
    Fogh-Andersen N; Christiansen TF; Komarmy L; Siggaard-Andersen O
    Clin Chem; 1978 Sep; 24(9):1545-52. PubMed ID: 28859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adjustment of ionized calcium concentration for serum pH is not a valid marker of calcium homeostasis: implications for identifying individuals at risk of calcium metabolic disorders.
    Lam V; Dhaliwal SS; Mamo JC
    Ann Clin Biochem; 2013 May; 50(Pt 3):224-9. PubMed ID: 23615406
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of storage on serum ionized calcium and pH values in clinically normal dogs.
    Schenck PA; Chew DJ; Brooks CL
    Am J Vet Res; 1995 Mar; 56(3):304-7. PubMed ID: 7771696
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Changes in canine ionised calcium under three storage conditions.
    Brennan SF; O'donovan J; Mooney CT
    J Small Anim Pract; 2006 Jul; 47(7):383-6. PubMed ID: 16842274
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of an electrolyte analyser for measurement of concentrations of ionized calcium and magnesium in cats.
    Unterer S; Gerber B; Glaus TM; Hässig M; Reusch CE
    Vet Res Commun; 2005 Nov; 29(8):647-59. PubMed ID: 16369879
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Recommendation on sampling, transport, and storage for the determination of the concentration of ionized calcium in whole blood, plasma, and serum. IFC Scientific Division, Working Group on Ion-Selective Electrodes (WGSE).
    Boink AB; Buckley BM; Christiansen TF; Covington AK; Maas AH; Müller-Plathe O; Sachs C; Siggaard-Andersen O
    J Int Fed Clin Chem; 1992 Sep; 4(4):147-52. PubMed ID: 10148305
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of serum ionized calcium with the ion-exchange electrode.
    Subryan VL; Popovtzer MM; Parks SD; Reeve EB
    Clin Chem; 1972 Dec; 18(12):1459-62. PubMed ID: 4639856
    [No Abstract]   [Full Text] [Related]  

  • 10. Measurement of ionised calcium in body fluids-a review.
    Robertson WG
    Ann Clin Biochem; 1976 Nov; 13(6):540-8. PubMed ID: 13702
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Serum ionized calcium by electrodes: new technology and methodology.
    Schwartz HD
    Clin Chim Acta; 1975 Nov; 64(3):227-39. PubMed ID: 241516
    [TBL] [Abstract][Full Text] [Related]  

  • 12. International Federation of Clinical Chemistry (IFCC), scientific division: IFCC recommendation on sampling transport and storage for the determination of the concentration of ionized calcium in whole blood, plasma and serum.
    Boink AB; Buckley BM; Christiansen TF; Covington AK; Maas AH; Müller-Plathe O; Sachs C; Siggaard-Andersen O
    Eur J Clin Chem Clin Biochem; 1991 Nov; 29(11):767-72. PubMed ID: 1782285
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ionized calcium: its significance and clinical usefulness.
    Forman DT; Lorenzo L
    Ann Clin Lab Sci; 1991; 21(5):297-304. PubMed ID: 1952778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ionized calcium analyzer with a built-in pH correction.
    Fogh-Andersen N
    Clin Chem; 1981 Jul; 27(7):1264-7. PubMed ID: 7237795
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anomalies in pH 7.40 correction in ionised calcium analysers.
    Sachs C; Chaneac M; Rabouine P; Kindermans C; Dechaux M
    Ann Clin Biochem; 1989 Nov; 26 ( Pt 6)():542-6. PubMed ID: 2619235
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of pH and NaCl on measurements of ionized calcium in matrices of serum and human albumin with a new calcium-selective electrode.
    Rehfeld SJ; Barkeley J; Loken HF
    Clin Chem; 1984 Feb; 30(2):304-7. PubMed ID: 6692542
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.
    Bowers GN; Brassard C; Sena SF
    Clin Chem; 1986 Aug; 32(8):1437-47. PubMed ID: 3524900
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a new automatic calcium ion analyzer.
    Madsen S; Olgaard K
    Clin Chem; 1977; 23(4):690-4. PubMed ID: 14794
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a new semiautomatic electrode system for simultaneous measurement of ionized calcium and pH.
    Thode J; Wandrup J; Aas F; Siggaard-Andersen O
    Scand J Clin Lab Invest; 1982 Sep; 42(5):407-15. PubMed ID: 7156853
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Method for the determination of ionized calcium in clinical practice].
    Porsová I; Blahos J; Chytil V; Kotas J
    Vnitr Lek; 1990 Apr; 36(4):379-86. PubMed ID: 2356614
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.