2. Percutaneous renal biopsy: an audit of a 2 year experience with the Biopty gun. Voss DM; Lynn KL N Z Med J; 1995 Jan; 108(992):8-10. PubMed ID: 7862364 [TBL] [Abstract][Full Text] [Related]
3. Safety and efficacy of kidney transplant biopsy: Tru-Cut needle vs sonographically guided Biopty gun. Mahoney MC; Racadio JM; Merhar GL; First MR AJR Am J Roentgenol; 1993 Feb; 160(2):325-6. PubMed ID: 8424343 [TBL] [Abstract][Full Text] [Related]
4. Ultrasonography-directed native renal biopsy: comparison of an automated biopsy device with a needle system. Kumar A; Mitchell MJ; Aggarwal S; Fraser DB; Trillo AA Can Assoc Radiol J; 1992 Oct; 43(5):359-63. PubMed ID: 1393701 [TBL] [Abstract][Full Text] [Related]
5. Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidneys using a 14-gauge Biopty gun. Preda A; Van Dijk LC; Van Oostaijen JA; Pattynama PM Eur Radiol; 2003 Mar; 13(3):527-30. PubMed ID: 12594555 [TBL] [Abstract][Full Text] [Related]
6. Conventional 15 G needle technique for renal biopsy compared with ultrasound-guided spring-loaded 18 G needle biopsy. Cozens NJ; Murchison JT; Allan PL; Winney RJ Br J Radiol; 1992 Jul; 65(775):594-7. PubMed ID: 1515897 [TBL] [Abstract][Full Text] [Related]
7. Percutaneous renal biopsy of native kidneys: a single-center experience of 1,055 biopsies. Korbet SM; Volpini KC; Whittier WL Am J Nephrol; 2014; 39(2):153-62. PubMed ID: 24526094 [TBL] [Abstract][Full Text] [Related]
8. Adequacy and complication rates with 14- vs. 16-gauge automated needles in percutaneous renal biopsy of native kidneys. Chunduri S; Whittier WL; Korbet SM Semin Dial; 2015; 28(2):E11-4. PubMed ID: 25441680 [TBL] [Abstract][Full Text] [Related]
9. Percutaneous biopsy in diffuse renal disease: comparison of 18- and 14-gauge automated biopsy devices. Song JH; Cronan JJ J Vasc Interv Radiol; 1998; 9(4):651-5. PubMed ID: 9684839 [TBL] [Abstract][Full Text] [Related]
10. [A new automated renal biopsy technique under ultrasound guidance]. Ohmori H; Arimoto K; Taki M; Kosaka K; Kumon H; Ohmori H Nihon Jinzo Gakkai Shi; 1990 Apr; 32(4):409-14. PubMed ID: 2198364 [TBL] [Abstract][Full Text] [Related]
11. Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys. Nyman RS; Cappelen-Smith J; al Suhaibani H; Alfurayh O; Shakweer W; Akhtar M Acta Radiol; 1997 May; 38(3):431-6. PubMed ID: 9191436 [TBL] [Abstract][Full Text] [Related]
12. Technique of renal biopsy by ultrasound guided percutaneous puncture with a spring loaded "gun". Bondestam S; Kontkanen T; Taavitsainen M; Tiula E Scand J Urol Nephrol; 1992; 26(3):265-7. PubMed ID: 1439602 [TBL] [Abstract][Full Text] [Related]
13. Real-time ultrasound-guided renal biopsy with a biopsy gun in children: safety and efficacy. Kersnik Levart T; Kenig A; Buturović Ponikvar J; Ferluga D; Avgustin Cavić M; Kenda RB Acta Paediatr; 2001 Dec; 90(12):1394-7. PubMed ID: 11853335 [TBL] [Abstract][Full Text] [Related]
14. Percutaneous pediatric renal biopsy: use of the biopsy gun. Poster RB; Jones DB; Spirt BA Radiology; 1990 Sep; 176(3):725-7. PubMed ID: 2202013 [TBL] [Abstract][Full Text] [Related]
15. Free-hand, ultrasound-guided percutaneous renal biopsy: experience from a single operator. Tang S; Li JH; Lui SL; Chan TM; Cheng IK; Lai KN Eur J Radiol; 2002 Jan; 41(1):65-9. PubMed ID: 11750155 [TBL] [Abstract][Full Text] [Related]
16. Percutaneous native renal biopsy: comparison of a 1.2-mm spring-driven system with a traditional 2-mm hand-driven system. Doyle AJ; Gregory MC; Terreros DA Am J Kidney Dis; 1994 Apr; 23(4):498-503. PubMed ID: 8154484 [TBL] [Abstract][Full Text] [Related]
17. Blinded comparison of biopsy needles and automated devices in vitro: 2. Biopsy of medical renal disease. Hopper KD; Abendroth CS; Sturtz KW; Matthews YL; Shirk SJ; Stevens LA AJR Am J Roentgenol; 1993 Dec; 161(6):1299-301. PubMed ID: 8249746 [TBL] [Abstract][Full Text] [Related]
18. Percutaneous real-time ultrasound-guided renal biopsy by automated biopsy gun in children: safety and complications. Sinha MD; Lewis MA; Bradbury MG; Webb NJ J Nephrol; 2006; 19(1):41-4. PubMed ID: 16523424 [TBL] [Abstract][Full Text] [Related]
19. Percutaneous renal biopsy: comparison of manual and automated puncture techniques with native and transplanted kidneys. Riehl J; Maigatter S; Kierdorf H; Schmitt H; Maurin N; Sieberth HG Nephrol Dial Transplant; 1994; 9(11):1568-74. PubMed ID: 7870344 [TBL] [Abstract][Full Text] [Related]
20. [Value of ultrasound-guided percutaneous renal biopsy in diagnosis of the renal diseases]. Horvatić I; Hrkać A; Zivko M; Kozjak D; Galesić K Acta Med Croatica; 2007 Sep; 61(4):399-403. PubMed ID: 18044476 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]