159 related articles for article (PubMed ID: 1406232)
1. Microsurgical use of polydioxanone (PDS) suture: an experimental report.
Takeishi M; Hirase Y; Kojima T
Microsurgery; 1992; 13(5):268-72. PubMed ID: 1406232
[TBL] [Abstract][Full Text] [Related]
2. Morphological aspects of microarterial anastomoses: a comparison of nylon with polydioxanone.
Thomson SR; Gregory MA; Mars M; Natasen J; Naicker T; Baker LW
Br J Plast Surg; 1995 Apr; 48(3):165-71. PubMed ID: 7735680
[TBL] [Abstract][Full Text] [Related]
3. Comparison of 10-0 polypropylene and 10-0 nylon sutures in rat arterial anastomosis.
Chen LE; Seaber AV; Urbaniak JR
Microsurgery; 1993; 14(5):328-33. PubMed ID: 8332053
[TBL] [Abstract][Full Text] [Related]
4. Study on microvascular anastomosis of arteries with absorbable polyglyconate suture.
Huang GK; Li HQ; Wu XM
Microsurgery; 1995; 16(7):505-9. PubMed ID: 8544712
[TBL] [Abstract][Full Text] [Related]
5. Microvascular anastomoses in growing vessels: a long-term evaluation of nonabsorbable suture materials.
Chen LE; Seaber AV; Urbaniak JR
J Reconstr Microsurg; 1993 May; 9(3):183-9. PubMed ID: 8515396
[TBL] [Abstract][Full Text] [Related]
6. Polydioxanone absorbable sutures in vascular anastomoses: experimental and preliminary clinical studies.
Wang ZG; Pu LQ; Li GD; Du W; Symes JF
Cardiovasc Surg; 1994 Aug; 2(4):508-13. PubMed ID: 7953459
[TBL] [Abstract][Full Text] [Related]
7. Use of fibrin glue to minimize bleeding of microvascular repairs in hypertensive rats.
Isogai N; Fukunishi K; Kamiishi H
Microsurgery; 1992; 13(6):321-4. PubMed ID: 1453933
[TBL] [Abstract][Full Text] [Related]
8. Effectiveness of a new non-thrombogenic bio-adhesive in microvascular anastomoses.
Dowbak GM; Rohrich RJ; Robinson JB; Peden E
J Reconstr Microsurg; 1994 Nov; 10(6):383-6. PubMed ID: 7884734
[TBL] [Abstract][Full Text] [Related]
9. Use of continuous horizontal mattress suture technique in end-to-side microsurgical anastomosis.
Başar H; Erol B; Tetik C
Hand Surg; 2012; 17(3):419-27. PubMed ID: 23061959
[TBL] [Abstract][Full Text] [Related]
10. 2-octylcyanoacrylate-assisted microvascular anastomosis: comparison with a conventional suture technique in rat femoral arteries.
Ang ES; Tan KC; Tan LH; Ng RT; Song IC
J Reconstr Microsurg; 2001 Apr; 17(3):193-201. PubMed ID: 11336151
[TBL] [Abstract][Full Text] [Related]
11. Vessel anastomosis using a venous cuff and two sutures: an experimental study in rat femoral and epigastric vessels.
Nakayama Y; Soeda S; Kiyosawa T
J Reconstr Microsurg; 1988 Jul; 4(4):335-9. PubMed ID: 3050066
[TBL] [Abstract][Full Text] [Related]
12. End-to-end versus end-to-side arterial anastomosis patency in microvascular surgery.
Dotson RJ; Bishop AT; Wood MB; Schroeder A
Microsurgery; 1998; 18(2):125-8. PubMed ID: 9674928
[TBL] [Abstract][Full Text] [Related]
13. Subclavian flap angioplasty with absorbable suture polydioxanone (PDS). An experimental study in growing piglets.
Friberg LG; Mellgren GW; Eriksson BO; Björkerud S
Scand J Thorac Cardiovasc Surg; 1987; 21(1):9-14. PubMed ID: 3109024
[TBL] [Abstract][Full Text] [Related]
14. Use of continuous horizontal mattress suture techniques in microsurgery: an experimental study in rats.
Tetik C; Unal MB; Kocaoglu B; Erol B
J Hand Surg Am; 2005 May; 30(3):587-95. PubMed ID: 15925172
[TBL] [Abstract][Full Text] [Related]
15. A comparative study of the use of 9-0 PDS and 9-0 prolene in microvascular anastomosis.
Banic A; Francis I; Nilsson U
J Reconstr Microsurg; 1990 Jul; 6(3):293-7. PubMed ID: 2127290
[TBL] [Abstract][Full Text] [Related]
16. End-to-Side Microvascular Anastomosis on Rat Femoral Vessels Using Only 2-Throw Knot Interrupted Sututres - Evaluation of Feasibility and Patency Rates on Rat Femoral Vessels Model.
Pruthi N; Tyagi G; Gohil D
World Neurosurg; 2021 Apr; 148():e145-e150. PubMed ID: 33359520
[TBL] [Abstract][Full Text] [Related]
17. Who needs extra time? Amniotic membrane wrapped pauci-suture model for rapid anastomoses
Ercin BS; Bicer A; Yigitturk G; Cinar C; Cavusoglu T; Uyanikgil Y; Gurler T
J Plast Surg Hand Surg; 2019 Apr; 53(2):89-96. PubMed ID: 30654665
[TBL] [Abstract][Full Text] [Related]
18. Scanning electron microscopy studies of needle and suture damage in rat carotid and femoral arteries.
Longa EZ; Weinstein PR; Chater G
Microsurgery; 1984; 5(4):169-74. PubMed ID: 6392817
[TBL] [Abstract][Full Text] [Related]
19. Absorbable PDS-II suture and nonabsorbable polypropylene suture in aortic anastomoses in growing piglets.
Chang SH; Weng ZC; Yang AH; Lai ST
J Formos Med Assoc; 1998 Mar; 97(3):165-9. PubMed ID: 9549265
[TBL] [Abstract][Full Text] [Related]
20. Effect of optical temperature feedback control on patency in laser-soldered microvascular anastomosis.
Pohl D; Bass LS; Stewart R; Chiu DT
J Reconstr Microsurg; 1998 Jan; 14(1):23-9; discussion 29-30. PubMed ID: 9523999
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]