These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 1411017)

  • 1. [Digital subtraction angiography for the assessment of myocardial perfusion].
    Felder LM; Hess OM; Vassalli F; Jiang Z; Grimm J; Krayenbühl HP
    Schweiz Rundsch Med Prax; 1992 Oct; 81(43):1277-80. PubMed ID: 1411017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Coronary vasomotion and coronary flow reserve during exercise.
    Hess OM; Felder L; Gaglione A; Buechi M; Vassalli F; Jiang Z; Grimm J; Krayenbuehl HP
    Basic Res Cardiol; 1991; 86 Suppl 2():193-201. PubMed ID: 1953611
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is atrial pacing needed for determination of coronary flow reserve by parametric imaging?
    Vassalli G; Hess OM; Krogmann ON; Oechslin E; Grimm J; Jiang Z; Krayenbuehl HP
    Am J Cardiol; 1993 Feb; 71(5):415-9. PubMed ID: 8430629
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].
    Haude M; Caspari G; Baumgart D; Spiller P; Heusch G; Erbel R
    Herz; 1997 Apr; 22(2):72-86. PubMed ID: 9206707
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Digital subtraction angiographic assessment of the coronary arteries and coronary flow reserve.
    Vogel RA; Mancini GB; Bates ER
    Int J Card Imaging; 1985; 1(4):225-32. PubMed ID: 3916437
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Densitometric studies in digital subtraction angiography: assessment of pulmonary and myocardial perfusion.
    Bürsch JH
    Herz; 1985 Aug; 10(4):208-14. PubMed ID: 3899885
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Assessment of myocardial perfusion using digital subtraction angiography].
    Ohta M
    J Cardiol Suppl; 1987; 15():35-9. PubMed ID: 3334252
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparison of myocardial perfusion assessments by digital subtraction angiography with those of left ventricular wall dynamics].
    Ohtani N; Matsuzaki M; Miura T; Katayama K; Kohno M; Yano M; Ono S; Fujii T; Murata K; Ogawa H
    J Cardiol; 1990; 20(4):963-76. PubMed ID: 2133731
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Digital subtraction angiographic imaging of coronary flow reserve.
    Cusma JT; Toggart EJ; Folts JD; Peppler WW; Hangiandreou NJ; Lee CS; Mistretta CA
    Circulation; 1987 Feb; 75(2):461-72. PubMed ID: 3802449
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Analysis of digital subtraction angiography for estimating flow reserve in critical coronary artery stenosis].
    Kotoku S; Matsuzaki M; Otani N; Miura T; Ozaki M; Ogawa H; Toma Y; Katayama K; Kono M; Fujii T
    J Cardiol; 1988 Dec; 18(4):899-912. PubMed ID: 3267728
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Regional myocardial coronary blood flow reserve in hypertrophic cardiomyopathy assessed by digital subtraction coronary angiography].
    Terashima S; Nakamura T; Furukawa K; Matsubara K; Onishi K; Shiga K; Miyazaki H; Kawata K; Tatsukawa H; Tatsumi T
    Kokyu To Junkan; 1990 Oct; 38(10):1021-7. PubMed ID: 2267432
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of coronary flow reserve by digital angiography: validation of a practical method not requiring power injection or electrocardiographic gating.
    Gurley JC; Nissen SE; Elion JL; Booth DC; DeMaria AN
    J Am Coll Cardiol; 1990 Jul; 16(1):190-7. PubMed ID: 2358592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Angiographic and physiologic assessment of coronary flow and myocardial perfusion in the cardiac catheterization laboratory.
    Vijayalakshmi K; De Belder MA
    Acute Card Care; 2008; 10(2):69-78. PubMed ID: 17906987
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Myocardial ischemia in hypertrophic cardiomyopathy: evaluation by 201Tl myocardial scintigraphy, digital subtraction coronary angiography and catheter-tip Doppler flowmetry].
    Katsume H; Sugihara H; Azuma A; Nakamura T; Furukawa K; Terashima S
    Kokyu To Junkan; 1992 Feb; 40(2):121-7. PubMed ID: 1533051
    [No Abstract]   [Full Text] [Related]  

  • 15. Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve.
    Nissen SE; Elion JL; Booth DC; Evans J; DeMaria AN
    Circulation; 1986 Mar; 73(3):562-71. PubMed ID: 3948361
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Evaluation of myocardial perfusion based on digital subtraction angiocardiography measured contrast medium flow times].
    Haude M; Jehle J; Löss B; Pölitz B; Schmiel FK; Spiller P
    Z Kardiol; 1985 Dec; 74(12):692-9. PubMed ID: 3913175
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of three different principles in the assessment of coronary flow reserve from digital angiograms.
    Simon R; Herrmann G; Amende I
    Int J Card Imaging; 1990; 5(2-3):203-12. PubMed ID: 2230297
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Evaluation of coronary blood flow using digital subtraction technique and cine coronary angiography: a preliminary report].
    Uwatoko M; Miyagi Y; Nomura M; Shiga Y; Koike A; Tateishi R; Mitsuguchi F; Mano K; Hishida H; Mizuno Y
    J Cardiol; 1988 Jun; 18(2):279-90. PubMed ID: 2977791
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Can digital subtraction myocardial perfusion imaging studies offer information for postangioplasty lesion assessment?
    Kern MJ
    Cathet Cardiovasc Diagn; 1998 Sep; 45(1):25-6. PubMed ID: 9736346
    [No Abstract]   [Full Text] [Related]  

  • 20. Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term results.
    Haude M; Brennecke R; Erbel R; Lang M; Deutsch HP; Renneisen U; Meyer J
    Int J Card Imaging; 1990; 5(2-3):183-90. PubMed ID: 2146328
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.