These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 1412553)

  • 1. [The compatibility of dentures made from precious metals and from corrosion-resistant steels with nitride coatings].
    Panchova VP; Kotliar AM; Savidova EK; Steglik TV; Zhivkova LV; Tarasov IuA
    Stomatologiia (Mosk); 1992; (2):67-9. PubMed ID: 1412553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study of corrosion between a titanium implant and dental alloys.
    Reclaru L; Meyer JM
    J Dent; 1994 Jun; 22(3):159-68. PubMed ID: 8027459
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Galvanic corrosion between dental precious alloys and magnetic stainless steels used for dental magnetic attachments.
    Takahashi N; Takada Y; Okuno O
    Dent Mater J; 2008 Mar; 27(2):237-42. PubMed ID: 18540398
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The late results of using fixed dentures made of stainless steel with a titanium nitride-based finish coating].
    Zotov VM; Murashkin NI; Sirota AV
    Stomatologiia (Mosk); 1990; (4):51-2. PubMed ID: 2251702
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The electrochemical indices of soldered dentures with titanium nitride-based multilayered coatings].
    Kotliar AM; Panchokha VP; Sevidova EK; Steglik TV; Zhivkova LV; Tarasov IuA
    Stomatologiia (Mosk); 1990; (5):53-6. PubMed ID: 1980755
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intraoral corrosion resulting from coupling dental implants and restorative metallic systems.
    Lemons JE; Lucas LC; Johansson BI
    Implant Dent; 1992; 1(2):107-12. PubMed ID: 1288802
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corrosion of coupled metals in a dental magnetic attachment system.
    Iimuro FT; Yoneyama T; Okuno O
    Dent Mater J; 1993 Dec; 12(2):136-44. PubMed ID: 8004908
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Multilayer protective nitride coatings on metal dentures].
    Napadov MA; Andreev AA; Sapozhnikov AL; Maslennikov MM; Zharov NA
    Stomatologiia (Mosk); 1986; 65(5):53-4. PubMed ID: 3538507
    [No Abstract]   [Full Text] [Related]  

  • 9. [The clinical manifestations of the electrochemical processes due to the finishing treatment of dentures made from stainless steel].
    Gozhiĭ AG; Sagatelian GR; Gozhaia LD; Bol'shakov GV
    Stomatologiia (Mosk); 1998; 77(3):46-50. PubMed ID: 9643115
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of coupling methods on galvanic corrosion behavior of commercially pure titanium with dental precious alloys.
    Al-Ali S; Oshida Y; Andres CJ; Barco MT; Brown DT; Hovijitra S; Ito M; Nagasawa S; Yoshida T
    Biomed Mater Eng; 2005; 15(4):307-16. PubMed ID: 16010039
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Galvanic corrosion between various combinations of orthodontic brackets and archwires.
    Bakhtari A; Bradley TG; Lobb WK; Berzins DW
    Am J Orthod Dentofacial Orthop; 2011 Jul; 140(1):25-31. PubMed ID: 21724083
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of restorative and implant alloys galvanically coupled to titanium.
    Venugopalan R; Lucas LC
    Dent Mater; 1998 Jun; 14(3):165-72. PubMed ID: 10196792
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro corrosion behavior of 13 prosthodontic alloys.
    Canay S; Oktemer M
    Quintessence Int; 1992 Apr; 23(4):279-87. PubMed ID: 1502304
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of surface area ratios and bacteria on electrochemical behavior of galvanically coupled titanium.
    Koh I; Oshida Y; Andres CJ; Gregory RL
    Int J Prosthodont; 2008; 21(5):433-6. PubMed ID: 18950067
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Corrosion behavior of dental alloys coated with titanium niobium oxinitride].
    Thull R
    Dtsch Zahnarztl Z; 1991 Nov; 46(11):712-7. PubMed ID: 1817869
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Galvanic corrosion of metal injection molded (MIM) and conventional brackets with nickel-titanium and copper-nickel-titanium archwires.
    Siargos B; Bradley TG; Darabara M; Papadimitriou G; Zinelis S
    Angle Orthod; 2007 Mar; 77(2):355-60. PubMed ID: 17319774
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On electric current creation in patients treated with osseointegrated dental bridges.
    Nilner K; Lekholm U
    Swed Dent J Suppl; 1985; 28():85-92. PubMed ID: 3904066
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Galvanism in patients wearing dentures made of silver-palladium alloy].
    Nazarov GI; Spiridonov LG
    Stomatologiia (Mosk); 1983; 62(2):60-1. PubMed ID: 6574640
    [No Abstract]   [Full Text] [Related]  

  • 19. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biodegradation of restorative metallic systems.
    Lucas LC; Lemons JE
    Adv Dent Res; 1992 Sep; 6():32-7. PubMed ID: 1292459
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.