These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 1414090)

  • 1. Bovine vectocardiography: a comparative study relative to the validity of four tridimensional lead systems.
    Amory H; Rollin F; Genicot B; Lekeux P
    Zentralbl Veterinarmed A; 1992 Aug; 39(6):453-69. PubMed ID: 1414090
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Normal electro- and vectorcardiographic data in the growing Friesian calf using a semi-orthogonal lead system.
    Amory H; Genicot B; Rollin F; Beduin JM; Lekeux P
    Zentralbl Veterinarmed A; 1993 Mar; 40(2):81-92. PubMed ID: 8480464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative study of the body surface electrocardiogram in double-muscled and conventional calves.
    Amory H; Rollin FA; Genicot BC; Beduin JM; Lekeux PM
    Can J Vet Res; 1993 Jul; 57(3):139-45. PubMed ID: 8358673
    [TBL] [Abstract][Full Text] [Related]  

  • 4. McFee and Parungao orthogonal lead vectocardiography in normal dogs.
    Chastain CB; Riedesel DH; Pearson PT
    Am J Vet Res; 1974 Feb; 35(2):275-80. PubMed ID: 4813323
    [No Abstract]   [Full Text] [Related]  

  • 5. Visual transform applications for estimating the spatial QRS-T angle from the conventional 12-lead ECG: Kors is still most Frank.
    Cortez D; Sharma N; Devers C; Devers E; Schlegel TT
    J Electrocardiol; 2014; 47(1):12-9. PubMed ID: 24099887
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interrelationship of some electrocardiogram amplitudes, time intervals and respiration in the horse.
    Miller PJ; Holmes JR
    Res Vet Sci; 1984 May; 36(3):370-4. PubMed ID: 6463382
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Studies on the sympathetic nervous system: T wave vectorcardiogram in cattle.
    Gregory NG; Wotton SB
    Res Vet Sci; 1981 Jan; 30(1):75-8. PubMed ID: 7244385
    [No Abstract]   [Full Text] [Related]  

  • 8. Quantitative M-mode and two-dimensional echocardiography in calves.
    Amory H; Jakovljevic S; Lekeux P
    Vet Rec; 1991 Jan; 128(2):25-31. PubMed ID: 2017840
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Electrocardiography in healthy and diseased cattle. 1. Electrocardiographic and vectorcardiographic statistics in 2 age groups].
    Ghergariu S; Moldovan A; Danielesco N
    Zentralbl Veterinarmed A; 1970 Aug; 17(7):598-612. PubMed ID: 4990268
    [No Abstract]   [Full Text] [Related]  

  • 10. Spatial vector changes during ventricular depolarisation using a semi-orthogonal lead system--a study of 190 cases.
    Holmes JR
    Equine Vet J; 1976 Jan; 8(1):1-16. PubMed ID: 1253775
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The variability of the QRS loop in the orthogonal lead system of frank and schmitt (SVEC III) (author's transl)].
    Hiltmann WD
    Basic Res Cardiol; 1975; 70(1):87-102. PubMed ID: 1122221
    [TBL] [Abstract][Full Text] [Related]  

  • 12. ECG-derived spatial QRS-T angle is strongly associated with hypertrophic cardiomyopathy.
    Cortez D; Schlegel TT; Ackerman MJ; Bos JM
    J Electrocardiol; 2017; 50(2):195-202. PubMed ID: 27839835
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative electrocardiography and vectorcardiography in postnatally developing rats.
    Diez U; Schwartze H
    J Electrocardiol; 1991 Jan; 24(1):53-62. PubMed ID: 2056268
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Studies into equine electrocardiography and vectorcardiography. IV. Vector distributions in some arrhythmias.
    Holmes JR; Alps BJ
    Can J Comp Med Vet Sci; 1967 Sep; 31(9):219-25. PubMed ID: 4227915
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Age differences in the spatial vectors and vectorcardiogram utilizing various orthogonal electrocardiographic lead systems.
    Arsenescu G; Sabău M; Xenia Hasu B; Szöts G
    Adv Cardiol; 1976; 16():108-10. PubMed ID: 1274725
    [No Abstract]   [Full Text] [Related]  

  • 16. [Precision-controlled echocardiographic left ventricular function parameters by repeated measurement on three consecutive days in trained and untrained warmblood horses].
    Gehlen H; Marnette S; Rohn K; Kreienbrock L; Stadler P
    Dtsch Tierarztl Wochenschr; 2005 Feb; 112(2):48-54. PubMed ID: 15787314
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computer analysis of the non-angular parameters of the QRSsE loop and orthogonal lead QRS characteristics in necropsy-verified normal dogs.
    Musselman EE; Church KE
    J Electrocardiol; 1983 Jul; 16(3):263-8. PubMed ID: 6619701
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Orientation and configuration of vectorcardiographic QRS loops from normal cats.
    Coulter DB; Calvert CA
    Am J Vet Res; 1981 Feb; 42(2):282-9. PubMed ID: 7258778
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Mean values and extreme physiologic changes of QRS, T vectors and their divergence angle in a spatial electrocardiographic study. Study of 57 healthy subjects of both sexes aged between 15 and 78].
    Bellanca G; Cataldo C; D'Antonio E; Picarella B; Di Stefano P
    Minerva Cardioangiol; 1969 Nov; 17(11):886-9. PubMed ID: 5404816
    [No Abstract]   [Full Text] [Related]  

  • 20. Vectorcardiography in experimental myocardial infarction. Serial changes and correlation between QRS loop change and the infarction size.
    Tseng CD; Tseng YZ; Carson W; Lo HM; Hsu KL; Chiang FT; Wu TL
    Jpn Heart J; 1995 May; 36(3):349-65. PubMed ID: 7650842
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.