These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 1424686)

  • 1. Generalized approach to inverse problems in tomography: image reconstruction for spatially variant systems using natural pixels.
    Baker JR; Budinger TF; Huesman RH
    Crit Rev Biomed Eng; 1992; 20(1-2):47-71. PubMed ID: 1424686
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reconstruction of 2D PET data with Monte Carlo generated system matrix for generalized natural pixels.
    Vandenberghe S; Staelens S; Byrne CL; Soares EJ; Lemahieu I; Glick SJ
    Phys Med Biol; 2006 Jun; 51(12):3105-25. PubMed ID: 16757866
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
    Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
    Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enhancing the performance of model-based elastography by incorporating additional a priori information in the modulus image reconstruction process.
    Doyley MM; Srinivasan S; Dimidenko E; Soni N; Ophir J
    Phys Med Biol; 2006 Jan; 51(1):95-112. PubMed ID: 16357433
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A fast image reconstruction algorithm based on penalized-likelihood estimate.
    Sheng J; Ying L
    Med Eng Phys; 2005 Oct; 27(8):679-86. PubMed ID: 16139765
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems.
    Stayman JW; Fessler JA
    IEEE Trans Med Imaging; 2004 Mar; 23(3):269-84. PubMed ID: 15027520
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noniterative MAP reconstruction using sparse matrix representations.
    Cao G; Bouman CA; Webb KJ
    IEEE Trans Image Process; 2009 Sep; 18(9):2085-99. PubMed ID: 19556196
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pixel-by-pixel deconvolution of bolus-tracking data: optimization and implementation.
    Sourbron S; Dujardin M; Makkat S; Luypaert R
    Phys Med Biol; 2007 Jan; 52(2):429-47. PubMed ID: 17202625
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET data.
    Obi T; Matej S; Lewitt RM; Herman GT
    IEEE Trans Med Imaging; 2000 May; 19(5):474-84. PubMed ID: 11021690
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization.
    Yu Z; Thibault JB; Bouman CA; Sauer KD; Hsieh J
    IEEE Trans Image Process; 2011 Jan; 20(1):161-75. PubMed ID: 20643609
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.
    Cohen-Bacrie C; Goussard Y; Guardo R
    IEEE Trans Med Imaging; 1997 Oct; 16(5):562-71. PubMed ID: 9368111
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Advances in computers and image processing with applications in nuclear medicine.
    Todd-Pokropek A
    Q J Nucl Med; 2002 Mar; 46(1):62-9. PubMed ID: 12072846
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Image reconstruction in electrical impedance tomography based on genetic algorithm].
    Hou W; Mo Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):107-10. PubMed ID: 12744177
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conditional entropy maximization for PET image reconstruction using adaptive mesh model.
    Zhu H; Shu H; Zhou J; Dai X; Luo L
    Comput Med Imaging Graph; 2007 Apr; 31(3):166-77. PubMed ID: 17368841
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On the optimality of the gridding reconstruction algorithm.
    Sedarat H; Nishimura DG
    IEEE Trans Med Imaging; 2000 Apr; 19(4):306-17. PubMed ID: 10909926
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Real-time image reconstruction for spiral MRI using fixed-point calculation.
    Liao JR
    IEEE Trans Med Imaging; 2000 Jul; 19(7):690-8. PubMed ID: 11055784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Localized prior knowledge and optimal interpolation in high-resolution tomography.
    Willis AJ; Jager M; Eggers J; Koch RD
    IEEE Trans Biomed Eng; 1998 Apr; 45(4):538-41. PubMed ID: 9556972
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Consecutive projections onto convex sets.
    Degenhard A; Hayes C; Leach MO
    Phys Med Biol; 2002 Mar; 47(6):N61-6. PubMed ID: 11936184
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Windowed image reconstruction for time-of-flight positron emission tomography.
    Kao CM
    Phys Med Biol; 2008 Jul; 53(13):3431-45. PubMed ID: 18547913
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
    Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
    Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.