111 related articles for article (PubMed ID: 1446430)
1. Debris from cobalt-chrome cable may cause acetabular loosening.
Kelley SS; Johnston RC
Clin Orthop Relat Res; 1992 Dec; (285):140-6. PubMed ID: 1446430
[TBL] [Abstract][Full Text] [Related]
2. Cemented total hip replacement cable debris and acetabular construct durability.
Altenburg AJ; Callaghan JJ; Yehyawi TM; Pedersen DR; Liu SS; Leinen JA; Dahl KA; Goetz DD; Brown TD; Johnston RC
J Bone Joint Surg Am; 2009 Jul; 91(7):1664-70. PubMed ID: 19571089
[TBL] [Abstract][Full Text] [Related]
3. Complications of a cable grip system.
Silverton CD; Jacobs JJ; Rosenberg AG; Kull L; Conley A; Galante JO
J Arthroplasty; 1996 Jun; 11(4):400-4. PubMed ID: 8792246
[TBL] [Abstract][Full Text] [Related]
4. Comparison of the outcome following the fixation of osteotomies or fractures associated with total hip replacement using cables or wires: the results at five years.
Berton C; Puskas GJ; Christofilopoulos P; Stern R; Hoffmeyer P; Lübbeke A
J Bone Joint Surg Br; 2012 Nov; 94(11):1475-81. PubMed ID: 23109625
[TBL] [Abstract][Full Text] [Related]
5. Trochanteric union following revision total hip arthroplasty.
Bal BS; Maurer BT; Harris WH
J Arthroplasty; 1998 Jan; 13(1):29-33. PubMed ID: 9493535
[TBL] [Abstract][Full Text] [Related]
6. Current status of trochanteric reattachment in complex total hip arthroplasty.
Barrack RL; Butler RA
Clin Orthop Relat Res; 2005 Dec; 441():237-42. PubMed ID: 16331009
[TBL] [Abstract][Full Text] [Related]
7. The outcome of trochanteric reattachment in revision total hip arthroplasty with a Cable Grip System: mean 6-year follow-up.
McCarthy JC; Bono JV; Turner RH; Kremchek T; Lee J
J Arthroplasty; 1999 Oct; 14(7):810-4. PubMed ID: 10537255
[TBL] [Abstract][Full Text] [Related]
8. Trochanteric osteotomy for revision total hip arthroplasty. 97% union rate using a comprehensive approach.
Schutzer SF; Harris WH
Clin Orthop Relat Res; 1988 Feb; 227():172-83. PubMed ID: 3338206
[TBL] [Abstract][Full Text] [Related]
9. Fixation systems of greater trochanteric osteotomies: biomechanical and clinical outcomes.
Jarit GJ; Sathappan SS; Panchal A; Strauss E; Di Cesare PE
J Am Acad Orthop Surg; 2007 Oct; 15(10):614-24. PubMed ID: 17916785
[TBL] [Abstract][Full Text] [Related]
10. Cerclage wire fixation of trochanteric osteotomies in complex hip revision: our experience and comparison with cable-plate fixation.
Collado A; Arvinius C; Serrano L; Otero J; Moro E; Marco F
Hip Int; 2022 Sep; 32(5):672-676. PubMed ID: 33601917
[TBL] [Abstract][Full Text] [Related]
11. Chevron osteotomy and single wire reattachment of the greater trochanter in primary and revision total hip arthroplasty.
Berry DJ; Müller ME
Clin Orthop Relat Res; 1993 Sep; (294):155-61. PubMed ID: 8358908
[TBL] [Abstract][Full Text] [Related]
12. Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases.
Davey JR; Harris WH
Clin Orthop Relat Res; 1988 Jun; (231):97-102. PubMed ID: 3370892
[TBL] [Abstract][Full Text] [Related]
13. Trochanteric fixation by cable grip in hip replacement.
Ritter MA; Eizember LE; Keating EM; Faris PM
J Bone Joint Surg Br; 1991 Jul; 73(4):580-1. PubMed ID: 2071639
[TBL] [Abstract][Full Text] [Related]
14. Trochanteric osteotomy and wire fixation: a comparison of 2 techniques.
Nercessian OA; Newton PM; Joshi RP; Sheikh B; Eftekhar NS
Clin Orthop Relat Res; 1996 Dec; (333):208-16. PubMed ID: 8981898
[TBL] [Abstract][Full Text] [Related]
15. Treatment of comminuted trochanteric fractures and non-union of trochanteric osteotomy in revision total hip arthroplasty.
Wu LD; Bernasek TL
Chin J Traumatol; 2003 Oct; 6(5):265-9. PubMed ID: 14514361
[TBL] [Abstract][Full Text] [Related]
16. The Frank Stinchfield Award. Contribution of cable debris generation to accelerated polyethylene wear.
Hop JD; Callaghan JJ; Olejniczak JP; Pedersen DR; Brown TD; Johnston RC
Clin Orthop Relat Res; 1997 Nov; (344):20-32. PubMed ID: 9372755
[TBL] [Abstract][Full Text] [Related]
17. Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty.
Koyama K; Higuchi F; Kubo M; Okawa T; Inoue A
J Orthop Sci; 2001; 6(1):22-7. PubMed ID: 11289581
[TBL] [Abstract][Full Text] [Related]
18. Comparative mechanical properties of spinal cable and wire fixation systems.
Dickman CA; Papadopoulos SM; Crawford NR; Brantley AG; Gealer RL
Spine (Phila Pa 1976); 1997 Mar; 22(6):596-604. PubMed ID: 9089931
[TBL] [Abstract][Full Text] [Related]
19. A system for trochanteric osteotomy and reattachment for total hip arthroplasty with a ninety-nine percent union rate.
Jensen NF; Harris WH
Clin Orthop Relat Res; 1986 Jul; (208):174-81. PubMed ID: 3720120
[TBL] [Abstract][Full Text] [Related]
20. Fixation of trochanteric slide osteotomies: a biomechanical study.
Plausinis D; Speirs AD; Masri BA; Garbuz DS; Duncan CP; Oxland TR
Clin Biomech (Bristol, Avon); 2003 Nov; 18(9):856-63. PubMed ID: 14527813
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]