These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
143 related articles for article (PubMed ID: 1446952)
1. Drill bit failure without implant involvement--an intraoperative complication in orthopaedic surgery. Hirt U; Auer JA; Perren SM Injury; 1992; 23 Suppl 2():S5-16. PubMed ID: 1446952 [TBL] [Abstract][Full Text] [Related]
2. Drill bit failure with implant involvement--an intraoperative complication in orthopaedic surgery. Fothi U; Perren SM; Auer JA Injury; 1992; 23 Suppl 2():S17-29. PubMed ID: 1446949 [TBL] [Abstract][Full Text] [Related]
3. A technique for removal of broken cannulated drill bit: Bassi's method. Bassi JL; Pankaj M; Navdeep S J Orthop Trauma; 2008 Jan; 22(1):56-8. PubMed ID: 18176167 [TBL] [Abstract][Full Text] [Related]
4. Vertebral canal location of a broken drill bit. Etchepareborde S; Mills J Vet Comp Orthop Traumatol; 2008; 21(1):94-7. PubMed ID: 18288350 [TBL] [Abstract][Full Text] [Related]
5. Frequency of instrument breakage during orthopaedic procedures and its effects on patients. Pichler W; Mazzurana P; Clement H; Grechenig S; Mauschitz R; Grechenig W J Bone Joint Surg Am; 2008 Dec; 90(12):2652-4. PubMed ID: 19047710 [TBL] [Abstract][Full Text] [Related]
6. The rate of instrument breakage during orthopaedic procedures. Price MV; Molloy S; Solan MC; Sutton A; Ricketts DM Int Orthop; 2002; 26(3):185-7. PubMed ID: 12073114 [TBL] [Abstract][Full Text] [Related]
7. Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review. Akhbar MFA; Sulong AW Ann Biomed Eng; 2021 Jan; 49(1):29-56. PubMed ID: 32860111 [TBL] [Abstract][Full Text] [Related]
8. Current practice regarding re-use of trauma instrumentation: results of a postal questionnaire survey. Ashford RU; Pande KC; Dey A Injury; 2001 Jan; 32(1):37-40. PubMed ID: 11164400 [TBL] [Abstract][Full Text] [Related]
9. Heat Generation During Bone Drilling: A Comparison Between Industrial and Orthopaedic Drill Bits. Hein C; Inceoglu S; Juma D; Zuckerman L J Orthop Trauma; 2017 Feb; 31(2):e55-e59. PubMed ID: 27682019 [TBL] [Abstract][Full Text] [Related]
10. Performance test of different 3.5 mm drill bits and consequences for orthopaedic surgery. Clement H; Zopf C; Brandner M; Tesch NP; Vallant R; Puchwein P Arch Orthop Trauma Surg; 2015 Dec; 135(12):1675-82. PubMed ID: 26407980 [TBL] [Abstract][Full Text] [Related]
13. Plunging when drilling: effect of using blunt drill bits. Alajmo G; Schlegel U; Gueorguiev B; Matthys R; Gautier E J Orthop Trauma; 2012 Aug; 26(8):482-7. PubMed ID: 22391404 [TBL] [Abstract][Full Text] [Related]
14. Development and application of an inside-to-out drill bit for anterior cruciate ligament reconstruction. Kim SG; Kurosawa H; Sakuraba K; Ikeda H; Takazawa S; Takazawa Y Arthroscopy; 2005 Aug; 21(8):1012. PubMed ID: 16086567 [TBL] [Abstract][Full Text] [Related]
15. Drilling of bone: a robust automatic method for the detection of drill bit break-through. Ong FR; Bouazza-Marouf K Proc Inst Mech Eng H; 1998; 212(3):209-21. PubMed ID: 9695640 [TBL] [Abstract][Full Text] [Related]
16. Removal of Broken Cannulated Drill Bit. Al-Kharouf KF; Abbas K; Anjum S; Khan FI Cureus; 2021 Nov; 13(11):e19706. PubMed ID: 34812332 [TBL] [Abstract][Full Text] [Related]
17. Drilling of bone: Effect of drill bit geometries on thermal osteonecrosis risk regions. Ali Akhbar MF; Yusoff AR Proc Inst Mech Eng H; 2019 Feb; 233(2):207-218. PubMed ID: 30572787 [TBL] [Abstract][Full Text] [Related]
18. Improved accuracy of navigated drilling using a drill alignment device. Kendoff D; Citak M; Gardner MJ; Stübig T; Krettek C; Hüfner T J Orthop Res; 2007 Jul; 25(7):951-7. PubMed ID: 17415775 [TBL] [Abstract][Full Text] [Related]
19. Removing a broken guidewire in the hip joint: treatment options and recommendations for preventing an avoidable surgical catastrophe. A case report. Salunke AA; Menon PH; Nambi GI; Tan J; Patel V; Chen Y; Kumar J Sao Paulo Med J; 2015; 133(6):531-4. PubMed ID: 26465811 [TBL] [Abstract][Full Text] [Related]
20. "Push back" technique: A simple method to remove broken drill bit from the proximal femur. Chouhan DK; Sharma S World J Orthop; 2015 Nov; 6(10):847-9. PubMed ID: 26601067 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]