These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 14500141)
21. Low Incidence of Pump-Related Infections in Jarvik 2000 Ventricular Assist Device Recipients with a Subcostal Driveline Exit Site. Letsou GV; Anand J; Ogburn E; Shah RM; Ganapathy AV; Cohn WE; Loor G; Frazier OH Tex Heart Inst J; 2019 Jun; 46(3):179-182. PubMed ID: 31708699 [TBL] [Abstract][Full Text] [Related]
22. A transapical-to-aorta double lumen cannula-based neonate left ventricular assist device efficiently unloads the left ventricle in neonate lambs. Zhou C; Wang D; Ballard-Croft C; Zhao G; Reda HK; Topaz S; Zwischenberger J J Thorac Cardiovasc Surg; 2017 Jan; 153(1):175-182. PubMed ID: 27692763 [TBL] [Abstract][Full Text] [Related]
23. Is the New Infant Jarvik 2015 Suitable for Patients<8 kg? In Vitro Study Using a Hybrid Simulator. Di Molfetta A; Zielinski K; Ferrari G; Kozarski M; Okrzeja P; Iacobelli R; Filippelli S; Perri G; Darowski M; Massetti M; Jarvik R; Amodeo A Artif Organs; 2019 Jan; 43(1):E1-E8. PubMed ID: 30398290 [TBL] [Abstract][Full Text] [Related]
24. Implantation of the Jarvik 2000® left ventricular assist device using the miniaturized extracorporeal circulation system - a case report. Formica F; Bamodu OA; Mariani S; Caruso R; Sangalli F; Paolini G Perfusion; 2016 Sep; 31(6):518-20. PubMed ID: 26791274 [TBL] [Abstract][Full Text] [Related]
25. First results of HeartWare left ventricular assist device implantation with tunnelling of the outflow graft through the transverse sinus. Hanke JS; Rojas SV; Cvitkovic T; Wiegmann B; Horke A; Warnecke G; Haverich A; Schmitto JD Interact Cardiovasc Thorac Surg; 2017 Oct; 25(4):503-508. PubMed ID: 28962493 [TBL] [Abstract][Full Text] [Related]
26. First Biventricular Jarvik 2000 Implants (Retroauricular Version) Via a Median Sternotomy. Brenner P; Wirth TJ; Liebermann A; Mihalj M; Güthoff S; Hagl C; Reichart B Exp Clin Transplant; 2016 Apr; 14(2):215-23. PubMed ID: 26867583 [TBL] [Abstract][Full Text] [Related]
28. Over 1200-day support with dual Jarvik 2000 biventricular assist device. Yoshioka D; Toda K; Yoshikawa Y; Sawa Y Interact Cardiovasc Thorac Surg; 2014 Dec; 19(6):1083-4. PubMed ID: 25228243 [TBL] [Abstract][Full Text] [Related]
29. Perioperative management of the left ventricular assist device recipient. Heath MJ; Dickstein ML Prog Cardiovasc Dis; 2000; 43(1):47-54. PubMed ID: 10935557 [TBL] [Abstract][Full Text] [Related]
30. Off-pump insertion of continuous flow left ventricular assist devices. Selzman CH; Sheridan BC J Card Surg; 2007; 22(4):320-2. PubMed ID: 17661774 [TBL] [Abstract][Full Text] [Related]
31. Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass. Frazier OH Ann Thorac Surg; 2003 Mar; 75(3):1028-30. PubMed ID: 12645747 [TBL] [Abstract][Full Text] [Related]
32. Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection. Frazier OH; Myers TJ; Westaby S; Gregoric ID Ann Thorac Surg; 2004 Jan; 77(1):133-42. PubMed ID: 14726049 [TBL] [Abstract][Full Text] [Related]
33. Exercise hemodynamics during long-term implantation of a left ventricular assist device in patients awaiting heart transplantation. Jaski BE; Branch KR; Adamson R; Peterson KL; Gordon JB; Hoagland PM; Smith SC; Daily PO; Dembitsky WP J Am Coll Cardiol; 1993 Nov; 22(6):1574-80. PubMed ID: 8227823 [TBL] [Abstract][Full Text] [Related]
34. Perioperative management of calves undergoing implantation of a left ventricular assist device. Wilson DV; Kantrowitz A; Pacholewicz J; Salat O; Paules BR; Zhou Y; Dawe EJ Vet Surg; 2000; 29(1):106-18. PubMed ID: 10653501 [TBL] [Abstract][Full Text] [Related]
35. Load-independent analysis of a pulsatile right ventricular assist device. Meyers CH; Peterseim DS; Uppal R; Jayawant AM; Campbell KA; Sabiston DC; Smith PK; Van Trigt P J Heart Lung Transplant; 1995; 14(1 Pt 1):177-85. PubMed ID: 7727467 [TBL] [Abstract][Full Text] [Related]
36. Stapled explant of the Jarvik 2000 left ventricular assist device. Banbury MK Ann Thorac Surg; 2003 Jan; 75(1):297. PubMed ID: 12537243 [TBL] [Abstract][Full Text] [Related]
37. Rapid pacing for the off-pump insertion of the Jarvik left ventricular assist device. Centofanti P; La Torre M; Attisani M; Sansone F; Rinaldi M Ann Thorac Surg; 2011 Oct; 92(4):1536-8. PubMed ID: 21958820 [TBL] [Abstract][Full Text] [Related]
38. University of Maryland surgical experience with the Jarvik 2000 axial flow ventricular assist device. Sorensen EN; Pierson RN; Feller ED; Griffith BP Ann Thorac Surg; 2012 Jan; 93(1):133-40. PubMed ID: 22112796 [TBL] [Abstract][Full Text] [Related]
39. Off-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy. Anyanwu AC; Fischer GW; Plotkina I; Pinney S; Adams DH Ann Thorac Surg; 2007 Oct; 84(4):1405-7. PubMed ID: 17889020 [TBL] [Abstract][Full Text] [Related]
40. Jarvik 2000 axial-flow ventricular assist device placement to a systemic morphologic right ventricle in congenitally corrected transposition of the great arteries. Tanoue Y; Jinzai Y; Tominaga R J Artif Organs; 2016 Mar; 19(1):97-9. PubMed ID: 26341249 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]