These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Antibody multispecificity in immunoassay interference. Levinson SS Clin Biochem; 1992 Apr; 25(2):77-87. PubMed ID: 1623581 [TBL] [Abstract][Full Text] [Related]
6. Immunoassay interference: a relatively rare but still important problem. Diamandis EP Clin Biochem; 2004 May; 37(5):331-2. PubMed ID: 15087246 [No Abstract] [Full Text] [Related]
7. Endogenous interference in immunoassays in clinical chemistry. A review. Weber TH; Käpyaho KI; Tanner P Scand J Clin Lab Invest Suppl; 1990; 201():77-82. PubMed ID: 2244186 [TBL] [Abstract][Full Text] [Related]
8. Eliminating heterophilic antibody interference for ferritin detection using Olympus F(ab')2 based reagent. Grouzmann E; Dayer N; Bain C; Neville CM; McCusker MD; Wang RY Clin Lab; 2008; 54(9-10):355-7. PubMed ID: 19097493 [TBL] [Abstract][Full Text] [Related]
9. Detection and elimination of interference by the heterophilic antibody in antibody microarray-based immunoassay. Yang X; Ji H; Lin X; Han Z; Liu F; Zhong R Clin Chem; 2011 Mar; 57(3):527-9. PubMed ID: 21098137 [No Abstract] [Full Text] [Related]
10. Cross-reactivity of Actrapid and three insulin analogues in the Abbott IMx insulin immunoassay. Song D; Davidson J Ann Clin Biochem; 2007 Mar; 44(Pt 2):197-8. PubMed ID: 17362590 [No Abstract] [Full Text] [Related]
11. Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays. Levinson SS; Miller JJ Clin Chim Acta; 2002 Nov; 325(1-2):1-15. PubMed ID: 12367762 [TBL] [Abstract][Full Text] [Related]
12. False-positive human chorionic gonadotropin levels caused by a heterophile antibody with the immunoradiometric assay. Check JH; Nowroozi K; Chase JS; Lauer C; Elkins B; Wu CH Am J Obstet Gynecol; 1988 Jan; 158(1):99-100. PubMed ID: 2447778 [TBL] [Abstract][Full Text] [Related]
13. Heteroantibody: phantom of the immunoassay. Nahm MH; Hoffmann JW Clin Chem; 1990 Jun; 36(6):829. PubMed ID: 2357816 [No Abstract] [Full Text] [Related]
14. A method for routine detection of heterophile antibody interference in the Abbott AxSYM hCG assay. Jones GR; Giannopoulos P Pathology; 2004 Aug; 36(4):364-6. PubMed ID: 15370140 [No Abstract] [Full Text] [Related]
15. A false positive case of high-sensitivity cardiac troponin in a patient with acute chest pain: Analytical study of the interference. Baroni S; Troiani E; Santonocito C; Moretti G; De Luca C; Antenucci M; Urbani A Clin Biochem; 2019 Apr; 66():103-105. PubMed ID: 30738031 [TBL] [Abstract][Full Text] [Related]
16. Antibody specificity in the immune response to insulin. Mirza IH; Wilkin TJ Int Arch Allergy Appl Immunol; 1989; 89(2-3):261-3. PubMed ID: 2668202 [TBL] [Abstract][Full Text] [Related]
17. Multiplex analysis of heterophil antibodies in patients with indeterminate HIV immunoassay results. Willman JH; Hill HR; Martins TB; Jaskowski TD; Ashwood ER; Litwin CM Am J Clin Pathol; 2001 May; 115(5):764-9. PubMed ID: 11345842 [TBL] [Abstract][Full Text] [Related]
18. Heterophilic antibody interference in immunometric assays. Bolstad N; Warren DJ; Nustad K Best Pract Res Clin Endocrinol Metab; 2013 Oct; 27(5):647-61. PubMed ID: 24094636 [TBL] [Abstract][Full Text] [Related]
19. Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum. Martins TB; Pasi BM; Litwin CM; Hill HR Clin Diagn Lab Immunol; 2004 Mar; 11(2):325-9. PubMed ID: 15013983 [TBL] [Abstract][Full Text] [Related]
20. Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using a human/mouse chimeric antibody to CEA as the tracer. Kuroki M; Matsumoto Y; Arakawa F; Haruno M; Murakami M; Kuwahara M; Ozaki H; Senba T; Matsuoka Y J Immunol Methods; 1995 Mar; 180(1):81-91. PubMed ID: 7897248 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]