These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
316 related articles for article (PubMed ID: 14501457)
1. In vivo characterization of piezoelectric transducers for implantable hearing AIDS. Javel E; Grant IL; Kroll K Otol Neurotol; 2003 Sep; 24(5):784-95. PubMed ID: 14501457 [TBL] [Abstract][Full Text] [Related]
2. [In vivo studies of a piezoelectric implantable hearing aid transducer in the cat]. Plinkert PK; Baumann JW; Lenarz T; Keiner S; Leysieffer H; Zenner HP HNO; 1997 Oct; 45(10):828-39. PubMed ID: 9445855 [TBL] [Abstract][Full Text] [Related]
3. Stapes vibration produced by the output transducer of an implantable hearing aid. Experimental study. Gyo K; Goode RL; Miller C Arch Otolaryngol Head Neck Surg; 1987 Oct; 113(10):1078-81. PubMed ID: 3620129 [TBL] [Abstract][Full Text] [Related]
4. In vivo experiments in the cat with an implantable piezoelectric hearing aid transducer. Plinkert PK; Baumann JW; Lenarz T; Keiner S; Leysieffer H; Zenner HP Eur Arch Otorhinolaryngol; 2000; 257(6):304-13. PubMed ID: 10993549 [TBL] [Abstract][Full Text] [Related]
5. The effects of mass loading the ossicles with a floating mass transducer on middle ear transfer function. Needham AJ; Jiang D; Bibas A; Jeronimidis G; O'Connor AF Otol Neurotol; 2005 Mar; 26(2):218-24. PubMed ID: 15793408 [TBL] [Abstract][Full Text] [Related]
6. Implantable hearing aids: changes in the auditory-evoked potential of the monkey in response to increased loading of the stapes. Wilson EP; Deddens AE; Lesser TH; Fredrickson JM Am J Otolaryngol; 1990; 11(3):149-52. PubMed ID: 2382781 [TBL] [Abstract][Full Text] [Related]
8. The effect of static force on round window stimulation with the direct acoustic cochlea stimulator. Maier H; Salcher R; Schwab B; Lenarz T Hear Res; 2013 Jul; 301():115-24. PubMed ID: 23276731 [TBL] [Abstract][Full Text] [Related]
9. Sensitivity and fidelity of a novel piezoelectric middle ear transducer. Chi FL; Wu Y; Yan QB; Shen YH; Jiang Y; Fan BH ORL J Otorhinolaryngol Relat Spec; 2009; 71(4):216-20. PubMed ID: 19707040 [TBL] [Abstract][Full Text] [Related]
10. Finite element analysis of the coupling between ossicular chain and mass loading for evaluation of implantable hearing device. Wang X; Hu Y; Wang Z; Shi H Hear Res; 2011 Oct; 280(1-2):48-57. PubMed ID: 21554941 [TBL] [Abstract][Full Text] [Related]
11. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure. Péus D; Dobrev I; Prochazka L; Thoele K; Dalbert A; Boss A; Newcomb N; Probst R; Röösli C; Sim JH; Huber A; Pfiffner F Hear Res; 2017 Aug; 351():88-97. PubMed ID: 28601531 [TBL] [Abstract][Full Text] [Related]
12. High frequency bone conduction auditory evoked potentials in the guinea pig: Assessing cochlear injury after ossicular chain manipulation. Bergin MJ; Bird PA; Vlajkovic SM; Thorne PR Hear Res; 2015 Dec; 330(Pt A):147-54. PubMed ID: 26493491 [TBL] [Abstract][Full Text] [Related]
13. Fully implantable hearing aid in the incudostapedial joint gap. Koch M; Eßinger TM; Stoppe T; Lasurashvili N; Bornitz M; Zahnert T Hear Res; 2016 Oct; 340():169-178. PubMed ID: 27041338 [TBL] [Abstract][Full Text] [Related]
14. [An implantable piezoelectric hearing aid transducer for inner ear hearing loss. I: Development of a prototype]. Leysieffer H; Baumann JW; Müller G; Zenner HP HNO; 1997 Oct; 45(10):792-800. PubMed ID: 9445852 [TBL] [Abstract][Full Text] [Related]
15. Concept and Evaluation of a New Piezoelectric Transducer for an Implantable Middle Ear Hearing Device. Liu H; Cheng J; Yang J; Rao Z; Cheng G; Yang S; Huang X; Wang M Sensors (Basel); 2017 Nov; 17(11):. PubMed ID: 29099047 [TBL] [Abstract][Full Text] [Related]
16. [Laser vibrometry. A middle ear and cochlear analyzer for noninvasive studies of middle and inner ear function disorders]. Rodriguez Jorge J; Zenner HP; Hemmert W; Burkhardt C; Gummer AW HNO; 1997 Dec; 45(12):997-1007. PubMed ID: 9486381 [TBL] [Abstract][Full Text] [Related]
17. [Intraoperative evaluation of signal transduction of prototypes of implantable hearing aid transducers in the human]. Zenner HP; Leysieffer H; Lenarz T; Baumann JW; Keiner S; Plinkert PK HNO; 1997 Oct; 45(10):855-66. PubMed ID: 9445858 [TBL] [Abstract][Full Text] [Related]
18. Middle-ear response in the chinchilla and its relationship to mechanics at the base of the cochlea. Ruggero MA; Rich NC; Robles L; Shivapuja BG J Acoust Soc Am; 1990 Apr; 87(4):1612-29. PubMed ID: 2341666 [TBL] [Abstract][Full Text] [Related]
19. Ear canal pressure variations versus negative middle ear pressure: comparison using distortion product otoacoustic emission measurement in humans. Sun XM Ear Hear; 2012; 33(1):69-78. PubMed ID: 21747284 [TBL] [Abstract][Full Text] [Related]
20. [Auditory brainstem responses evoked by direct mechanical stimulation of the ossicular chain. Objective preoperative testing of candidates for implantable hearing aids]. Hoth S; Lohaus M; Waldmann B HNO; 2003 Jul; 51(7):550-7. PubMed ID: 12904876 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]