  • 1. Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques.
    Iqbal MK; Maggiore F; Suh B; Edwards KR; Kang J; Kim S
    J Endod; 2003 Sep; 29(9):587-91. PubMed ID: 14503833
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An in vitro comparison of Profile GT and GTX nickel-titanium rotary instruments in apical transportation and length control in mandibular molar.
    Iqbal MK; Floratos S; Hsu YK; Karabucak B
    J Endod; 2010 Feb; 36(2):302-4. PubMed ID: 20113795
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of apical transportation between ProFile and ProTaper NiTi rotary instruments.
    Iqbal MK; Firic S; Tulcan J; Karabucak B; Kim S
    Int Endod J; 2004 Jun; 37(6):359-64. PubMed ID: 15186241
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative study of 6 rotary nickel-titanium systems and hand instrumentation for root canal preparation in severely curved root canals of extracted teeth.
    Celik D; Taşdemir T; Er K
    J Endod; 2013 Feb; 39(2):278-82. PubMed ID: 23321246
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The quality of apical canal preparation using hand and rotary instruments with specific criteria for enlargement based on initial apical file size.
    Tan BT; Messer HH
    J Endod; 2002 Sep; 28(9):658-64. PubMed ID: 12236311
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of three Ni-Ti rotary instruments in apical transportation.
    Javaheri HH; Javaheri GH
    J Endod; 2007 Mar; 33(3):284-6. PubMed ID: 17320715
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals.
    D'Amario M; Baldi M; Petricca R; De Angelis F; El Abed R; D'Arcangelo C
    J Endod; 2013 Dec; 39(12):1581-4. PubMed ID: 24238451
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences.
    Setzer FC; Kwon TK; Karabucak B
    J Endod; 2010 Jul; 36(7):1226-9. PubMed ID: 20630304
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.
    Guelzow A; Stamm O; Martus P; Kielbassa AM
    Int Endod J; 2005 Oct; 38(10):743-52. PubMed ID: 16164689
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing apical preparations of root canals shaped by nickel-titanium rotary instruments and nickel-titanium hand instruments.
    Deplazes P; Peters O; Barbakow F
    J Endod; 2001 Mar; 27(3):196-202. PubMed ID: 11487151
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of apical transportation between FlexMaster and Twisted Files rotary instruments.
    Duran-Sindreu F; García M; Olivieri JG; Mercadé M; Morelló S; Roig M
    J Endod; 2012 Jul; 38(7):993-5. PubMed ID: 22703668
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals.
    Alves Vde O; Bueno CE; Cunha RS; Pinheiro SL; Fontana CE; de Martin AS
    J Endod; 2012 Jan; 38(1):117-20. PubMed ID: 22152634
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro-computed tomographic evaluation of canal transportation instrumented by different kinematics rotary nickel-titanium instruments.
    Gergi R; Arbab-Chirani R; Osta N; Naaman A
    J Endod; 2014 Aug; 40(8):1223-7. PubMed ID: 25069937
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effectiveness of a manual glide path on the preparation of curved root canals by using Mtwo rotary instruments.
    Uroz-Torres D; González-Rodríguez MP; Ferrer-Luque CM
    J Endod; 2009 May; 35(5):699-702. PubMed ID: 19410086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of dentine removal using V-taper and K-Flexofile instruments.
    Akhlaghi NM; Kahali R; Abtahi A; Tabatabaee S; Mehrvarzfar P; Parirokh M
    Int Endod J; 2010 Nov; 43(11):1029-36. PubMed ID: 20636352
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of canal transportation and changes in canal curvature of two nickel-titanium rotary instruments.
    El Batouty KM; Elmallah WE
    J Endod; 2011 Sep; 37(9):1290-2. PubMed ID: 21846551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography.
    Özer SY
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Feb; 111(2):244-50. PubMed ID: 21167759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rotary nickel-titanium GT and ProTaper files for root canal shaping by novice operators: a radiographic and micro-computed tomography evaluation.
    Gekelman D; Ramamurthy R; Mirfarsi S; Paqué F; Peters OA
    J Endod; 2009 Nov; 35(11):1584-8. PubMed ID: 19840653
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vitro comparison of canal preparation using two automated rotary nickel-titanium instrumentation techniques.
    Jardine SJ; Gulabivala K
    Int Endod J; 2000 Jul; 33(4):381-91. PubMed ID: 11307215
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of apical transportation between ProFile and RaCe rotary instruments.
    García M; Duran-Sindreu F; Mercadé M; Bueno R; Roig M
    J Endod; 2012 Jul; 38(7):990-2. PubMed ID: 22703667
    [TBL] [Abstract][Full Text] [Related]  