These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
169 related articles for article (PubMed ID: 1450484)
21. Evaluation of cardiac function and venous return curves in awake, unanesthetized cialves with an implanted total artificial heart. Honda T; Nagai I; Nitta S; Igo SR; Edmonds CH; Hibbs CW; Kito Y; Fuqua JM; Akutsu T Trans Am Soc Artif Intern Organs; 1975; 21():362-7. PubMed ID: 1146009 [TBL] [Abstract][Full Text] [Related]
22. Right heart function during prosthetic left ventricular assistance in a porcine model of congestive heart failure. Chow E; Farrar DJ J Thorac Cardiovasc Surg; 1992 Sep; 104(3):569-78. PubMed ID: 1513147 [TBL] [Abstract][Full Text] [Related]
23. In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system. Tatsumi E; Nakamura M; Masuzawa T; Taenaka Y; Sohn YS; Nishimura T; Nakata M; Nakatani T; Ohno T; Endo S; Takiura K; Takewa Y; Kakuta Y; Takano H ASAIO J; 1997; 43(5):M619-25. PubMed ID: 9360119 [TBL] [Abstract][Full Text] [Related]
24. Myocardial contractility of the canine left ventricle during unsynchronized dual chamber pacing. Hosoya K; Takeda K; Nakamura Y; Masuda T; Matsuoka H J Cardiol; 1997 Jun; 29(6):337-43. PubMed ID: 9211093 [TBL] [Abstract][Full Text] [Related]
25. [Interpretation of the limits of survival during circulatory support in the dog]. Lesigne C; Saumont R; Bardou A; Lenne W; Birkui P; Lévy B Arch Mal Coeur Vaiss; 1975 May; 68(5):533-41. PubMed ID: 816310 [TBL] [Abstract][Full Text] [Related]
26. [Left cardiac output curve and pulmonary venous return curve in patients with various heart diseases]. Iida M; Gotoh K; Yagi Y; Deguchi F; Terashima Y; Nagashima K; Nomura M; Yasuda N; Fujiwara H; Hirakawa S J Cardiol; 1996 Jan; 27(1):21-7. PubMed ID: 8683431 [TBL] [Abstract][Full Text] [Related]
27. Development of the functionally total artificial heart using an artery pump. Li GR; Zhu XD ASAIO J; 2007; 53(3):288-91. PubMed ID: 17515716 [TBL] [Abstract][Full Text] [Related]
28. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data. Morley D; Litwak K; Ferber P; Spence P; Dowling R; Meyns B; Griffith B; Burkhoff D J Thorac Cardiovasc Surg; 2007 Jan; 133(1):21-8. PubMed ID: 17198776 [TBL] [Abstract][Full Text] [Related]
29. Cardiac output and left atrial pressure monitoring by right ventricular pressure waveform analysis for potential implantable device application. Xu D; Olivier NB; Mukkamala R IEEE Trans Biomed Eng; 2009 Sep; 56(9):2335-9. PubMed ID: 19457736 [TBL] [Abstract][Full Text] [Related]
30. In vitro development of automatic control for the actively filled electrohydraulic heart. Lioi AP; Orth JL; Crump KR; Diffee G; Dew PA; Nielsen SD; Olsen DB Artif Organs; 1988 Apr; 12(2):152-62. PubMed ID: 3291829 [TBL] [Abstract][Full Text] [Related]
31. Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart. Rosenberg G; Landis DL; Phillips WM; Stallsmith J; Pierce WS Trans Am Soc Artif Intern Organs; 1978; 24():341-4. PubMed ID: 362675 [TBL] [Abstract][Full Text] [Related]
32. Total artificial heart using neural and fuzzy controller. Lee M; Ahn JM; Min BG; Lee SY; Park CH Artif Organs; 1996 Nov; 20(11):1220-6. PubMed ID: 8908333 [TBL] [Abstract][Full Text] [Related]
33. Simple electrical model of the circulation to explore design parameters for a skeletal muscle ventricle. Voytik SL; Babbs CF; Badylak SF J Heart Transplant; 1990; 9(2):160-74. PubMed ID: 2319376 [TBL] [Abstract][Full Text] [Related]
34. In vitro controllability of the MagScrew total artificial heart system. Weber S; Doi K; Massiello AL; Byerman BP; Takagaki M; Fukamachi K; Donahue A; Chapman P; Hirschman G; Vitale N; Smith WA ASAIO J; 2002; 48(6):606-11. PubMed ID: 12455770 [TBL] [Abstract][Full Text] [Related]
35. Right-left ventricular balance in implanted electrically powered artificial hearts. Long JW; Khanwilkar P; Crump KR; Pantalos GM; Kinoshita M; Kim HC; Olsen DB ASAIO Trans; 1990; 36(3):M287-90. PubMed ID: 2252680 [TBL] [Abstract][Full Text] [Related]
36. Dynamic in vitro and in vivo performance of a permanent total artificial heart. Rosenberg G; Snyder AJ; Weiss WJ; Kusagawa H; Rawhouser MA; Prophet GA; Mehta S; Reibson JD; Cleary TJ Artif Organs; 1998 Jan; 22(1):87-94. PubMed ID: 9456234 [TBL] [Abstract][Full Text] [Related]
37. A tether-free, moving actuator total artificial heart. Min BG; Kim HC; Lee SH; Chang JK; Choi JW; Kim JW; Seo KP; Rho JR; Ahn H; Kim SW ASAIO Trans; 1990; 36(3):M249-51. PubMed ID: 2252669 [TBL] [Abstract][Full Text] [Related]
38. Development of an automatic control algorithm for the electrohydraulic total artificial heart without transducers. Kim HC; Khanwilkar PS; Crump KC; Smith KD; Bearnson GB; Olsen DB ASAIO Trans; 1991; 37(3):M501-3. PubMed ID: 1751252 [TBL] [Abstract][Full Text] [Related]
39. Right-left ventricular output balance in the totally implantable artificial heart. Olsen DB; White RK; Long JW; Khanwilkar PS Int J Artif Organs; 1991 Jun; 14(6):359-64. PubMed ID: 1885244 [TBL] [Abstract][Full Text] [Related]
40. Static state hemodynamic variables estimation model for the moving-actuator type total artificial heart. Part. I--cardiac output estimation. Om KS; Ahn JM; Min BG Int J Artif Organs; 1999 Jan; 22(1):21-6. PubMed ID: 10098581 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]