These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 14510525)

  • 21. A rabbit model for implanting continuous drug infusion pumps.
    Esper E; Wigness BD; Dombrovskis S; Michalek V; Rohde TD; Buchwald H
    ASAIO Trans; 1987; 33(1):28-32. PubMed ID: 3828159
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transauricular arterial or venous access for cardiovascular experimental protocols in animals.
    Karnabatidis D; Katsanos K; Diamantopoulos A; Kagadis GC; Siablis D
    J Vasc Interv Radiol; 2006 Nov; 17(11 Pt 1):1803-11. PubMed ID: 17142711
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Study of venous drainage in retrograde island flaps by fluorescence tracing technique in a rabbit model].
    Jing Z; Yu G; Wang D; You M; Zhang S
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Aug; 22(8):959-63. PubMed ID: 18773814
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Caffeine disposition in the pregnant rabbit. I. Pharmacokinetics following administration by intravenous bolus and continuous zero-order infusion.
    Dorrbecker SH; Raye JR; Dorrbecker BR; Kramer PA
    Dev Pharmacol Ther; 1988; 11(2):109-17. PubMed ID: 3371145
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of mannitol injection by intravenous catheter on ear vein endothelial cell apoptosis and venous thrombus in rabbits.
    Mo XR; Luo XJ; Li CP; Pan XF; Zhou LL
    Eur Rev Med Pharmacol Sci; 2015; 19(3):491-7. PubMed ID: 25720724
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accuracy of intravenous infusion pumps in continuous renal replacement therapies.
    Jenkins R; Harrison H; Chen B; Arnold D; Funk J
    ASAIO J; 1992; 38(4):808-10. PubMed ID: 1450476
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of fluid infusion pumps using different administration sets: preliminary observations.
    Petruccione I; Murison PJ
    Vet Anaesth Analg; 2020 Nov; 47(6):853-854. PubMed ID: 32962916
    [No Abstract]   [Full Text] [Related]  

  • 28. Predisposing factors to phlebitis in patients with peripheral intravenous catheters: a descriptive study.
    Uslusoy E; Mete S
    J Am Acad Nurse Pract; 2008 Apr; 20(4):172-80. PubMed ID: 18387013
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Factors Influencing the Accurate Administration of Peristaltic Finger Infusion Pumps Attached to Polyvinylchloride Infusion Sets Containing Tris(2-ethylhexyl) trimellitate].
    Umemura M; Arai D; Maegawa K; Shigeno K; Wakiya Y
    Yakugaku Zasshi; 2016; 136(5):761-7. PubMed ID: 27150932
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Simultaneous subcutaneous implantation of two osmotic minipumps connected to a jugular vein catheter in the rat.
    Wedel J; Weij M; Oosten AS; Hillebrands JL
    Lab Anim; 2014 Oct; 48(4):338-41. PubMed ID: 25002205
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A wearable intravenous infusion device facilitating ambulation: a pre-clinical report.
    Seo WH; Cho KH; Loh BG
    J Med Eng Technol; 2014 Jan; 38(1):42-8. PubMed ID: 24195745
    [TBL] [Abstract][Full Text] [Related]  

  • 32. High risk infusions--accuracy compromised by changes in patient venous pressure.
    Murphy RS; Wilcox SJ
    J Med Eng Technol; 2009; 33(6):470-4. PubMed ID: 19479606
    [TBL] [Abstract][Full Text] [Related]  

  • 33. American registered nurse medical device education: a comparison of simple and complex devices.
    McConnell EA
    Biomed Instrum Technol; 1995; 29(6):520-6. PubMed ID: 8574267
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An in vitro analysis of central venous drug delivery by continuous infusion: the effect of manifold design and port selection.
    Moss DR; Bartels K; Peterfreund GL; Lovich MA; Sims NM; Peterfreund RA
    Anesth Analg; 2009 Nov; 109(5):1524-9. PubMed ID: 19843791
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Rabbit Model for Prolonged Continuous Intravenous Infusion Via a Peripherally Inserted Central Catheter.
    Dor E; David T; Dekel Jaoui H; Schwartz A; Baruchi T; Torgeman A; Ben David A; Rosen O; Tal A; Rosner A; Zichel R; Diamant E
    Front Pharmacol; 2021; 12():637792. PubMed ID: 33897426
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Administration of ¹³¹I-Metaiodobenzylguanidine Using the Peristaltic Infusion Pump Method.
    de la Guardia M; McCammon S; Nielson K; Granger M
    J Nucl Med Technol; 2014 Jun; 42(2):109-13. PubMed ID: 24799606
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effects of using a micro-infusion pump without accompanying fluid at a low flow rate on patients undergoing cardiac surgery.
    Meng H; Chen F; He LH; Wan JH
    Transpl Immunol; 2022 Aug; 73():101611. PubMed ID: 35500846
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Connecting multiple low-flow intravenous infusions in the newborn: problems and possible solutions.
    Levi DS; Peterson N; Shah SD; Rakholia B; Haught A; Carman G
    Pediatr Crit Care Med; 2010 Mar; 11(2):275-81. PubMed ID: 20068501
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Performance of three large-volume infusion pumps with the monoplace hyperbaric chamber.
    Bell J; Weaver LK; Deru K
    Undersea Hyperb Med; 2016; 43(1):9-19. PubMed ID: 27000009
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accuracy of drug infusion pumps under computer control.
    Connor SB; Quill TJ; Jacobs JR
    IEEE Trans Biomed Eng; 1992 Sep; 39(9):980-2. PubMed ID: 1473827
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.