These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Secondary shielding barriers for diagnostic x-ray facilities: scatter and leakage revisited. Simpkin DJ; Dixon RL Health Phys; 1998 Mar; 74(3):350-65. PubMed ID: 9482601 [TBL] [Abstract][Full Text] [Related]
4. Primary shielding barriers for diagnostic x-ray facilities: a new model. Dixon RL; Simpkin DJ Health Phys; 1998 Feb; 74(2):181-9. PubMed ID: 9450588 [TBL] [Abstract][Full Text] [Related]
5. Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities. Kharrati H; Agrebi A; Karaoui MK Med Phys; 2007 Apr; 34(4):1398-404. PubMed ID: 17500471 [TBL] [Abstract][Full Text] [Related]
6. A study of scatter in diagnostic X-ray rooms. McVey G; Weatherburn H Br J Radiol; 2004 Jan; 77(913):28-38. PubMed ID: 14988135 [TBL] [Abstract][Full Text] [Related]
7. Surveyed data for structural shielding calculations of radiographic x-ray installations in Taiwan. Chen TR; Tyan YS; Chu CH; Wu MC; Tung CJ Health Phys; 2013 May; 104(5 Suppl 2):S60-7. PubMed ID: 23528275 [TBL] [Abstract][Full Text] [Related]
8. Derivation of factors for estimating the scatter of diagnostic x-rays from walls and ceiling slabs. Martin CJ; Sutton DG; Magee J; McVey S; Williams JR; Peet D J Radiol Prot; 2012 Dec; 32(4):373-96. PubMed ID: 23006642 [TBL] [Abstract][Full Text] [Related]
9. Radiation shielding for diagnostic radiology. Martin CJ Radiat Prot Dosimetry; 2015 Jul; 165(1-4):376-81. PubMed ID: 25813477 [TBL] [Abstract][Full Text] [Related]
11. [Effective dose transmission of diagnostic X-rays through concrete and lead shields]. Kato H Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Aug; 59(8):965-75. PubMed ID: 12960950 [TBL] [Abstract][Full Text] [Related]
12. Diagnostic X-ray shielding design based on an empirical model of photon attenuation. Archer BR; Thornby JI; Bushong SC Health Phys; 1983 May; 44(5):507-17. PubMed ID: 6853171 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of mean conversion coefficients from air-kerma to H Lopez Gonzales AH; Santos JC; Mariano L; Tomal A; Costa PR J Radiol Prot; 2016 Dec; 36(4):842-857. PubMed ID: 27739403 [TBL] [Abstract][Full Text] [Related]
14. [Reconsideration on methods for calculation of shielding thickness for scattered radiation at the maze of a high-energy X-ray therapy room (author's transl)]. Onai Y; Tomaru T; Uchida I; Maruyama T; Hashizume T Nihon Igaku Hoshasen Gakkai Zasshi; 1979 Feb; 39(2):167-9. PubMed ID: 450653 [No Abstract] [Full Text] [Related]
15. Shielding of medical imaging X-ray facilities: a simple and practical method. Bibbo G Australas Phys Eng Sci Med; 2017 Dec; 40(4):925-930. PubMed ID: 28983885 [TBL] [Abstract][Full Text] [Related]
16. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation. Jaradat AK; Biggs PJ Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304 [TBL] [Abstract][Full Text] [Related]
17. Recent history of the shielding of medical x-ray imaging facilities. Archer BR Health Phys; 2005 Jun; 88(6):579-86. PubMed ID: 15891455 [TBL] [Abstract][Full Text] [Related]
18. Mathematical modeling of the radiation dose received from photons passing over and through shielding walls in a PET/CT suite. Fog LS; Cormack J Health Phys; 2010 Dec; 99(6):769-79. PubMed ID: 21068595 [TBL] [Abstract][Full Text] [Related]
19. Numerical models for the determination of primary structural barriers for diagnostic x-ray facilities. Okunade AA Med Phys; 2004 Mar; 31(3):513-20. PubMed ID: 15070248 [TBL] [Abstract][Full Text] [Related]
20. Emission of fluorescent x-radiation from non-lead based shielding materials of protective clothing: a radiobiological problem? Schmid E; Panzer W; Schlattl H; Eder H J Radiol Prot; 2012 Sep; 32(3):N129-39. PubMed ID: 22809876 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]