These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Tube extender for revision of glaucoma drainage implants. Sarkisian SR; Netland PA J Glaucoma; 2007; 16(7):637-9. PubMed ID: 18091184 [TBL] [Abstract][Full Text] [Related]
3. Migration of glaucoma drainage device extender into anterior chamber after trauma. Sheets CW; Ramjattan TK; Smith MF; Doyle JW J Glaucoma; 2006 Dec; 15(6):559-61. PubMed ID: 17106372 [TBL] [Abstract][Full Text] [Related]
4. The effect of an Ahmed glaucoma valve implant on corneal endothelial cell density in children with glaucoma secondary to uveitis. Kalinina Ayuso V; Scheerlinck LM; de Boer JH Am J Ophthalmol; 2013 Mar; 155(3):530-5. PubMed ID: 23218690 [TBL] [Abstract][Full Text] [Related]
5. Management of uveitic glaucoma with Ahmed glaucoma valve implantation. Da Mata A; Burk SE; Netland PA; Baltatzis S; Christen W; Foster CS Ophthalmology; 1999 Nov; 106(11):2168-72. PubMed ID: 10571354 [TBL] [Abstract][Full Text] [Related]
6. Risk factors of shallow anterior chamber other than hypotony after Ahmed glaucoma valve implant. Park HY; Lee NY; Park CK J Glaucoma; 2009 Jan; 18(1):44-8. PubMed ID: 19142134 [TBL] [Abstract][Full Text] [Related]
7. Efficacy of the Ahmed S2 glaucoma valve compared with the Baerveldt 250-mm2 glaucoma implant. Goulet RJ; Phan AD; Cantor LB; WuDunn D Ophthalmology; 2008 Jul; 115(7):1141-7. PubMed ID: 18164068 [TBL] [Abstract][Full Text] [Related]
8. Long-term success in the correction of exposed glaucoma drainage tubes with a tube extender. Merrill KD; Suhr AW; Lim MC Am J Ophthalmol; 2007 Jul; 144(1):136-7. PubMed ID: 17601438 [TBL] [Abstract][Full Text] [Related]
9. A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma. Ayyala RS; Zurakowski D; Smith JA; Monshizadeh R; Netland PA; Richards DW; Layden WE Ophthalmology; 1998 Oct; 105(10):1968-76. PubMed ID: 9787371 [TBL] [Abstract][Full Text] [Related]
10. Ciliary sulcus Ahmed Glaucoma Valve tube placement in neovascular glaucoma. Rush R Ophthalmic Surg Lasers Imaging; 2009; 40(5):489-92. PubMed ID: 19772273 [TBL] [Abstract][Full Text] [Related]
11. Intraoperative management of nonfunctioning Ahmed glaucoma valve implant. Setabutr P; Bell NP; Feldman RM Ophthalmic Surg Lasers Imaging; 2006; 37(1):62-4. PubMed ID: 16468554 [TBL] [Abstract][Full Text] [Related]
12. Management of glaucoma drainage implant tube kink and obstruction with Pars Plana Clip. Netland PA; Schuman S Ophthalmic Surg Lasers Imaging; 2005; 36(2):167-8. PubMed ID: 15792322 [TBL] [Abstract][Full Text] [Related]
13. A novel surgical technique to prevent postoperative Ahmed valve tube exposure through conjunctiva: tenon advancement and duplication. Tamçelik N; Sarici AM; Yetik H; Ozkök A; Ozkiris A Ophthalmic Surg Lasers Imaging; 2010; 41(3):370-4. PubMed ID: 20507023 [TBL] [Abstract][Full Text] [Related]
14. [Implantation of Ahmed-type valve in the treatment of glaucoma, following penetrating keratoplasty]. Romaniuk W; Fronczek M; Szkaradek P; Dorecka M Klin Oczna; 2004; 106(1-2 Suppl):170-2. PubMed ID: 15510487 [TBL] [Abstract][Full Text] [Related]
15. Pars plana placement of Ahmed glaucoma valve tube through sclerotomy port in refractory glaucoma: A novel surgical technique. Gupta R; Varshney A Indian J Ophthalmol; 2020 Jan; 68(1):234-236. PubMed ID: 31856536 [TBL] [Abstract][Full Text] [Related]
16. Results of another modality for extending glaucoma drainage tubes. Smith MF; Doyle JW J Glaucoma; 1999 Oct; 8(5):310-4. PubMed ID: 10529931 [TBL] [Abstract][Full Text] [Related]
17. Ahmed glaucoma valve and single-plate Molteno implants in treatment of refractory glaucoma: a comparative study. Nassiri N; Kamali G; Rahnavardi M; Mohammadi B; Nassiri S; Rahmani L; Nassiri N Am J Ophthalmol; 2010 Jun; 149(6):893-902. PubMed ID: 20451896 [TBL] [Abstract][Full Text] [Related]
18. The Ahmed Glaucoma Valve in refractory glaucoma: experiences in Indian eyes. Das JC; Chaudhuri Z; Sharma P; Bhomaj S Eye (Lond); 2005 Feb; 19(2):183-90. PubMed ID: 15258600 [TBL] [Abstract][Full Text] [Related]
19. Extension of a retracted ciliary sulcus tube of Ahmed glaucoma implant with angiocatheter segment. Moghimi S; Mohammadi M Int Ophthalmol; 2012 Aug; 32(4):409-12. PubMed ID: 22562128 [TBL] [Abstract][Full Text] [Related]
20. Ahmed glaucoma valve implant for childhood glaucoma in Sturge-Weber syndrome with choroidal hemangioma. Wu SC; Lin KK Chang Gung Med J; 2006; 29(5):528-31. PubMed ID: 17214399 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]