224 related articles for article (PubMed ID: 14518662)
1. Hemoglobin variant HbG-coushatta (beta-22 Glu --> Ala) found by dissociation of blood glucose from values of HbA1C measured by HPLC.
Ogawa K; Bando T; Ogawa M; Miyazaki A; Nakanishi T; Shimizu A
Intern Med; 2003 Sep; 42(9):781-7. PubMed ID: 14518662
[TBL] [Abstract][Full Text] [Related]
2. [A variant hemoglobin found by dissociation of blood glucose from HbA1c on routine physical examination].
Ogawa K; Bando T; Ogawa M; Miyazaki A; Nakanishi T; Shimizu A
Rinsho Byori; 2003 Jun; 51(6):508-15. PubMed ID: 12884736
[TBL] [Abstract][Full Text] [Related]
3. Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method.
Chen D; Crimmins DL; Hsu FF; Lindberg FP; Scott MG
Clin Chem; 1998 Jun; 44(6 Pt 1):1296-301. PubMed ID: 9625056
[TBL] [Abstract][Full Text] [Related]
4. Effects of hemoglobin variants HbJ Bangkok, HbE, HbG Taipei, and HbH on analysis of glycated hemoglobin via ion-exchange high-performance liquid chromatography.
Zhang XM; Wen DM; Xu SN; Suo MH; Chen YQ
J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28407371
[TBL] [Abstract][Full Text] [Related]
5. Hb Westport [β121 (GH4) Glu>Asp; HBB:c.366A>C]: A novel β-globin variant interfering with HbA1c measurement.
Moore JA; Li BV; Wang D; Chan B; King RI; Florkowski CM
Clin Biochem; 2022 Sep; 107():62-66. PubMed ID: 35580651
[TBL] [Abstract][Full Text] [Related]
6. Mass spectrometry based characterization of Hb Beckman variant in a falsely elevated HbA(1c) sample.
Das R; Muralidharan M; Mitra G; Bhat V; Mathew B; Pal D; Ross C; Mandal AK
Anal Biochem; 2015 Nov; 489():53-8. PubMed ID: 26209877
[TBL] [Abstract][Full Text] [Related]
7. Method-dependent HbA1c values in a family with hemoglobin Himeji.
Nishihara E; Koga M; Kadowaki S; Murakami M; Harano K; Ito M; Kubota S; Amino N; Miyauchi A
Clin Chim Acta; 2011 Aug; 412(17-18):1689-92. PubMed ID: 21641339
[TBL] [Abstract][Full Text] [Related]
8. Two cases with Hb Andrew-Minneapolis showing high or low-normal HbA1c levels depending on the measurement method.
Kuramoto N; Koshibu M; Ishibashi M; Miyazaki A; Sumitani S; Kasayama S; Hirano T; Koga M
Clin Chim Acta; 2020 Feb; 501():229-233. PubMed ID: 31711758
[TBL] [Abstract][Full Text] [Related]
9. HbG-Coushatta: an unexpected discovery during HbA1c measurement.
Cheng X; Li M; Wu J; Su W
Clin Chim Acta; 2015 Apr; 444():163-6. PubMed ID: 25684455
[TBL] [Abstract][Full Text] [Related]
10. Hb I: A α-globin chain variant causing unexpected HbA
Xu A; Sun J; Li J; Chen W; Zheng R; Han Z; Ji L
J Clin Lab Anal; 2019 Feb; 33(2):e22671. PubMed ID: 30221391
[TBL] [Abstract][Full Text] [Related]
11. A nondiabetic case of hemoglobin variant (Hb Niigata) with inappropriately high and low HbA1c titers detected by different methods.
Watanabe T; Kato K; Yamada D; Midorikawa S; Sato W; Shiga M; Otsuka Y; Miura M; Harano K; Harano T
Clin Chem; 1998 Jul; 44(7):1562-4. PubMed ID: 9665442
[No Abstract] [Full Text] [Related]
12. Detection of two abnormal hemoglobins, Hb Manitoba and Hb G-Coushatta, during analysis of glycohemoglobin (A1c) by high-performance liquid chromatography.
Wong SC; Tesanovic M; Poon MC
Clin Chem; 1991 Aug; 37(8):1456-9. PubMed ID: 1868612
[TBL] [Abstract][Full Text] [Related]
13. Hemoglobin Hirose: A rare beta chain variant causing falsely low HbA1c by HPLC.
Estey MP; Rodriguez-Capote K; Adelowokan T; Higgins T
Clin Biochem; 2016 Apr; 49(6):498-501. PubMed ID: 26617061
[TBL] [Abstract][Full Text] [Related]
14. Hemoglobin Sherwood Forest detected by high performance liquid chromatography for hemoglobin A1c.
Schnedl WJ; Reisinger EC; Pieber TR; Lipp RW; Schreiber F; Hopmeier P; Krejs GJ
Am J Clin Pathol; 1995 Oct; 104(4):444-6. PubMed ID: 7572795
[TBL] [Abstract][Full Text] [Related]
15. Potential of MALDI-TOF mass spectrometry to overcome the interference of hemoglobin variants on HbA1c measurement.
Xu A; Xie W; Wang Y; Ji L
Clin Chem Lab Med; 2020 Jul; 59(1):233-239. PubMed ID: 32678801
[TBL] [Abstract][Full Text] [Related]
16. Comparison of glycation degrees of HbG-Coushatta and HbG-Taipei with HbA using liquid chromatography with tandem mass spectrometry.
Gao R; Yu S; Su W; Zhao F; Wang D; Zhang Y; Zhang T; Hu Y; Cheng X; Qiu L
Clin Chim Acta; 2021 Oct; 521():144-150. PubMed ID: 34224683
[TBL] [Abstract][Full Text] [Related]
17. Hemoglobin Raleigh results in factitiously low hemoglobin A1c when evaluated via immunoassay analyzer.
Jain N; Kesimer M; Hoyer JD; Calikoglu AS
J Diabetes Complications; 2011; 25(1):14-8. PubMed ID: 19896869
[TBL] [Abstract][Full Text] [Related]
18. 3 cases of variant hemoglobin Hb A2-Niigata detected by falsely high HbA1c values.
Ito M; Sano K; Koga M
Clin Chim Acta; 2020 Nov; 510():656-658. PubMed ID: 32860785
[TBL] [Abstract][Full Text] [Related]
19. Degree of discrepancy between HbA1c and glycemia in variant hemoglobin is smaller when HbA1c is measured by new-type Arkray HPLC compared with old-type HPLC.
Koga M; Kurebayashi S; Murai J; Saito H; Miyazaki A
Clin Biochem; 2014 Jan; 47(1-2):123-5. PubMed ID: 24128409
[TBL] [Abstract][Full Text] [Related]
20. Effects of common hemoglobin variants on HbA1c measurements in China: results for α- and β-globin variants measured by six methods.
Xu A; Chen W; Xia Y; Zhou Y; Ji L
Clin Chem Lab Med; 2018 Jul; 56(8):1353-1361. PubMed ID: 29626415
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]