These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

62 related articles for article (PubMed ID: 1451881)

  • 1. [Rematitan-pour-vacuum melting in two-chamber system].
    Lubberich A
    Dent Labor (Munch); 1992 Sep; 40(9):1485-8. PubMed ID: 1451881
    [No Abstract]   [Full Text] [Related]  

  • 2. A novel method for vacuum casting titanium.
    Hruska AR
    Int J Prosthodont; 1990; 3(2):142-5. PubMed ID: 2133381
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Differing expansion contributions of three investment materials used for casting titanium.
    Low D
    J Prosthodont; 2009 Jul; 18(5):444-9. PubMed ID: 19432764
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Titanium casting using the Titaniumer. Casting technic is not yet final].
    Geis-Gerstdorfer J; Weber H; Simonis A; Echkardt M; Haselberger D
    Dent Labor (Munch); 1989 Dec; 37(12):1789-92. PubMed ID: 2700446
    [No Abstract]   [Full Text] [Related]  

  • 5. Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.
    de Oliveira Correa G; Henriques GE; Mesquita MF; Sobrinho LC
    J Prosthet Dent; 2006 Mar; 95(3):243-8. PubMed ID: 16543023
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New improvement of the melting and casting machine for cobalt-chromium casting alloy using the vacuum method.
    Fukui H; Nishi T; Shinoda M; Sawada T; Hasegawa J
    Aichi Gakuin Daigaku Shigakkai Shi; 1974 Mar; 11(4):321-9. PubMed ID: 4616631
    [No Abstract]   [Full Text] [Related]  

  • 7. The longitudinal accuracy of fit of titanium implant superstructures superplastically formed on investment models.
    Soo S; Garriga-Majo D; Palmer RM; Curtis RV
    Dent Mater; 2004 Mar; 20(3):269-76. PubMed ID: 15209232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Dental titanium casting system].
    Cheng J; Guo T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Dec; 14(4):388-92. PubMed ID: 11367635
    [No Abstract]   [Full Text] [Related]  

  • 9. [Is titanium an alternative for base metal alloys?].
    Walter M; Böning K
    Dtsch Stomatol (1990); 1991; 41(9):315-9. PubMed ID: 1816859
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dimensional accuracy analysis of implant framework castings from 2 casting systems.
    Chang TL; Maruyama C; White SN; Son S; Caputo AA
    Int J Oral Maxillofac Implants; 2005; 20(5):720-5. PubMed ID: 16274145
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel method for titanium crown casting using a combination of wax patterns fabricated by a CAD/CAM system and a non-expanded investment.
    Zhang Z; Tamaki Y; Hotta Y; Miyazaki T
    Dent Mater; 2006 Jul; 22(7):681-7. PubMed ID: 16343607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Castability of low-melting ternary titanium alloys.
    al-Jabab AS; Greener EH; Lautenschlager EP; Gilber JL
    Northwest Dent Res; 1991; 2(2):21-2. PubMed ID: 1883610
    [No Abstract]   [Full Text] [Related]  

  • 13. [Determination of titanium flow by the tracer element molten method in the dental precision casting. 1. The principle of flow visualization and application to simple castings].
    Watanabe K; Okawa S; Miyakawa O; Nakano S; Shiokawa N; Kobayashi M
    Shika Zairyo Kikai; 1990 Jul; 9(4):623-32. PubMed ID: 2134828
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bond strength of three porcelains to two forms of titanium using two firing atmospheres.
    Atsü S; Berksun S
    J Prosthet Dent; 2000 Nov; 84(5):567-74. PubMed ID: 11105013
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The castability of unalloyed titanium in three different casting machines.
    Bessing C; Bergman M
    Swed Dent J; 1992; 16(3):109-13. PubMed ID: 1496457
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Casting of pure titanium: the O'Hara System and its dental application].
    Louis JP; Maeder Y; Reynette R
    Rev Fr Prothes Dent; 1989 Sep; (8):45-51. PubMed ID: 2698499
    [No Abstract]   [Full Text] [Related]  

  • 17. The effect of mold temperature on castability of CP Ti and Ti-6Al-4V castings into phosphate bonded investment materials.
    Oliveira PC; Adabo GL; Ribeiro RF; Rocha SS
    Dent Mater; 2006 Dec; 22(12):1098-102. PubMed ID: 16423386
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Ohara titanium casting system].
    Kitamura T
    Quintessenz Zahntech; 1988 May; 14(5):590-604. PubMed ID: 3059393
    [No Abstract]   [Full Text] [Related]  

  • 19. In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures.
    Koke U; Wolf A; Lenz P; Gilde H
    J Oral Rehabil; 2004 May; 31(5):477-82. PubMed ID: 15140174
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Studies on titanium casting. (1) Influence of the mold temperature on titanium castings].
    Kuroiwa A; Wada K; Hibino Y; Yoshida O; Kakumoto Y; Kouchi H; Nagayama K; Hashimoto H
    Shika Zairyo Kikai; 1990 Mar; 9(2):279-88. PubMed ID: 2135519
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.