These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 14519372)

  • 21. Intramedullary pressure, strain on the diaphysis and increase in cortical temperature when reaming the femoral medullary cavity--a comparison of blunt and sharp reamers.
    Müller C; McIff T; Rahn BA; Pfister U; Weller S
    Injury; 1993; 24 Suppl 3():S22-30. PubMed ID: 8168872
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Adult respiratory distress syndrome, pneumonia, and mortality following thoracic injury and a femoral fracture treated either with intramedullary nailing with reaming or with a plate. A comparative study.
    Bosse MJ; MacKenzie EJ; Riemer BL; Brumback RJ; McCarthy ML; Burgess AR; Gens DR; Yasui Y
    J Bone Joint Surg Am; 1997 Jun; 79(6):799-809. PubMed ID: 9199375
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Influence of the compression force on the intramedullary pressure development in reaming of the femoral medullary cavity.
    Müller C; McIff T; Rahn BA; Pfister U; Perren SM; Weller S
    Injury; 1993; 24 Suppl 3():S36-9. PubMed ID: 8168874
    [TBL] [Abstract][Full Text] [Related]  

  • 24. History and development of suction-irrigation-reaming.
    Green J
    Injury; 2010 Nov; 41 Suppl 2():S24-31. PubMed ID: 21144923
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Fat embolism: the reaming controversy.
    Giannoudis PV; Tzioupis C; Pape HC
    Injury; 2006 Oct; 37 Suppl 4():S50-8. PubMed ID: 16990061
    [TBL] [Abstract][Full Text] [Related]  

  • 26. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.
    Gary JL; Munz JW; Burgess AR
    Orthopedics; 2014 Jun; 37(6):393-6. PubMed ID: 24972428
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Stimulation of the local femoral inflammatory response to fracture and intramedullary reaming: a preliminary study of the source of the second hit phenomenon.
    Morley JR; Smith RM; Pape HC; MacDonald DA; Trejdosiewitz LK; Giannoudis PV
    J Bone Joint Surg Br; 2008 Mar; 90(3):393-9. PubMed ID: 18310768
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Limits of internal fixation in long-bone fracture.
    Nieto H; Baroan C
    Orthop Traumatol Surg Res; 2017 Feb; 103(1S):S61-S66. PubMed ID: 28082050
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Extent of bluntness and damage to reamers from hospitals.
    Müller C; Rahn BA; Pfister U; Weller S
    Injury; 1993; 24 Suppl 3():S31-5. PubMed ID: 8168873
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of femoral fracture and intramedullary fixation on lung capillary leak.
    Willis BH; Carden DL; Sadasivan KK
    J Trauma; 1999 Apr; 46(4):687-92. PubMed ID: 10217235
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [An unsual case of an extensive heat necrosis].
    Rüedi T
    Ther Umsch; 2004 Dec; 61(12):721-4. PubMed ID: 15651167
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Intramedullary pressure development and its sequelae in intramedullary nailing].
    Stürmer KM; Schuchardt W
    Chir Forum Exp Klin Forsch; 1979; ():207-11. PubMed ID: 456129
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A cadaver model evaluating femoral intramedullary reaming: a comparison between new reamer design (Pressure Sentinel) and a novel suction/irrigation reamer (RIA).
    Goplen G; Wilson JA; McAffrey M; Deluzio K; Leighton R
    Injury; 2010 Nov; 41 Suppl 2():S38-42. PubMed ID: 21144925
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Quantitative assessment of bone injury and repair after reamed and unreamed locked intramedullary nailing.
    Schemitsch EH; Turchin DC; Kowalski MJ; Swiontkowski MF
    J Trauma; 1998 Aug; 45(2):250-5. PubMed ID: 9715180
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The treatment of intramedullary osteomyelitis of the femur and tibia using the Reamer-Irrigator-Aspirator system and antibiotic cement rods.
    Kanakaris N; Gudipati S; Tosounidis T; Harwood P; Britten S; Giannoudis PV
    Bone Joint J; 2014 Jun; 96-B(6):783-8. PubMed ID: 24891579
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Influence of controlled reaming on fat intravasation after femoral osteotomy in sheep.
    Mousavi M; David R; Schwendenwein I; Schaden E; Marlovits S; Kolonja A; Schwanzer E; Heinz T; Vécsei V
    Clin Orthop Relat Res; 2002 Jan; (394):263-70. PubMed ID: 11795742
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Nonunion following intramedullary nailing of the femur with and without reaming. Results of a multicenter randomized clinical trial.
    Canadian Orthopaedic Trauma Society
    J Bone Joint Surg Am; 2003 Nov; 85(11):2093-6. PubMed ID: 14630836
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Infected non-union of the tibial shaft treated by Küntscher intramedullary reaming and n ail fixation. A report of four cases.
    Lidgren L; Onnerfält R
    Acta Orthop Scand; 1982 Aug; 53(4):669-74. PubMed ID: 7102286
    [No Abstract]   [Full Text] [Related]  

  • 39. Influence of reaming versus nonreaming in intramedullary nailing on local infection rate: experimental investigation in rabbits.
    Melcher GA; Metzdorf A; Schlegel U; Ziegler WJ; Perren SM; Printzen G
    J Trauma; 1995 Dec; 39(6):1123-8. PubMed ID: 7500406
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Thermal damage to the tibial diaphysis caused by intramedullary reaming (author's transl)].
    Povacz F
    Unfallheilkunde; 1979 Mar; 82(3):126-8. PubMed ID: 419631
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.