120 related articles for article (PubMed ID: 14522208)
1. Development and testing of a modular strain measurement clip.
Whan G; Phillips J; Bullock S; Runciman RJ; Pearce S; Hurtig M
J Biomech; 2003 Nov; 36(11):1669-74. PubMed ID: 14522208
[TBL] [Abstract][Full Text] [Related]
2. Determining effective centroid position in biomechanical testing: a technique for simplifying whole bone analysis.
Whan G; Runciman RJ; Hurtig M
J Biomech Eng; 2005 Oct; 127(5):736-41. PubMed ID: 16248302
[TBL] [Abstract][Full Text] [Related]
3. Calculation of tibial loading using strain gauges.
Funk JR; Crandall JR
Biomed Sci Instrum; 2006; 42():160-5. PubMed ID: 16817602
[TBL] [Abstract][Full Text] [Related]
4. Ex vivo calibration and validation of in vivo equine bone strain measures.
Davies HM
Equine Vet J; 2009 Mar; 41(3):225-8. PubMed ID: 19469225
[TBL] [Abstract][Full Text] [Related]
5. Fatigue behavior of the equine third metacarpus: mechanical property analysis.
Gibson VA; Stover SM; Martin RB; Gibeling JC; Willits NH; Gustafson MB; Griffin LV
J Orthop Res; 1995 Nov; 13(6):861-8. PubMed ID: 8544022
[TBL] [Abstract][Full Text] [Related]
6. In vivo measurement of bone strain in the horse.
Turner AS; Mills EJ; Gabel AA
Am J Vet Res; 1975 Nov; 36(11):1573-9. PubMed ID: 1190599
[TBL] [Abstract][Full Text] [Related]
7. Measurement of cancellous bone strain during mechanical tests using a new extensometer device.
Boyd S; Shrive N; Wohl G; Müller R; Zernicke R
Med Eng Phys; 2001 Jul; 23(6):411-6. PubMed ID: 11551817
[TBL] [Abstract][Full Text] [Related]
8. A device for the measurement of pedicle screw moments by means of internal strain gauges.
Smith TS; Yerby SA; McLain RF; McKinley TO
J Biomech Eng; 1996 Aug; 118(3):423-5. PubMed ID: 8872267
[TBL] [Abstract][Full Text] [Related]
9. An in vitro comparison of bone deformation measured with surface and staple mounted strain gauges.
Arndt A; Westblad P; Ekenman I; Halvorsen K; Lundberg A
J Biomech; 1999 Dec; 32(12):1359-63. PubMed ID: 10569716
[TBL] [Abstract][Full Text] [Related]
10. Miniature C-shaped transducers for chordae tendineae force measurements.
Nielsen SL; Soerensen DD; Libergren P; Yoganathan AP; Nygaard H
Ann Biomed Eng; 2004 Aug; 32(8):1050-7. PubMed ID: 15446501
[TBL] [Abstract][Full Text] [Related]
11. Description and application of instrumented staples for measuring in vivo bone strain.
Buttermann GR; Janevic JT; Lewis JL; Lindquist CM; Wood KB; Schendel MJ
J Biomech; 1994 Aug; 27(8):1087-94. PubMed ID: 8089163
[TBL] [Abstract][Full Text] [Related]
12. Development and validation of a series of three-dimensional finite element models of the equine metacarpus.
Les CM; Keyak JH; Stover SM; Taylor KT
J Biomech; 1997 Jul; 30(7):737-42. PubMed ID: 9239555
[TBL] [Abstract][Full Text] [Related]
13. Measurements of bone strain in foals with altered foot balance.
Firth EC; Schamhardt HC; Hartman W
Am J Vet Res; 1988 Feb; 49(2):261-5. PubMed ID: 3348536
[TBL] [Abstract][Full Text] [Related]
14. Bone stress in the horse forelimb during locomotion at different gaits: a comparison of two experimental methods.
Biewener AA; Thomason J; Goodship A; Lanyon LE
J Biomech; 1983; 16(8):565-76. PubMed ID: 6643529
[TBL] [Abstract][Full Text] [Related]
15. Effects of gamma radiation sterilization and strain rate on compressive behavior of equine cortical bone.
Tüfekci K; Kayacan R; Kurbanoğlu C
J Mech Behav Biomed Mater; 2014 Jun; 34():231-42. PubMed ID: 24607761
[TBL] [Abstract][Full Text] [Related]
16. Fibre optic Bragg grating sensors: an alternative method to strain gauges for measuring deformation in bone.
Fresvig T; Ludvigsen P; Steen H; Reikerås O
Med Eng Phys; 2008 Jan; 30(1):104-8. PubMed ID: 17369073
[TBL] [Abstract][Full Text] [Related]
17. Collagen fiber organization is related to mechanical properties and remodeling in equine bone. A comparison of two methods.
Martin RB; Lau ST; Mathews PV; Gibson VA; Stover SM
J Biomech; 1996 Dec; 29(12):1515-21. PubMed ID: 8945649
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of resilient abutment components on measured strain using dynamic loading conditions.
Morton D; Stanford CM; Aquilino SA
J Prosthet Dent; 1998 Jul; 80(1):46-51. PubMed ID: 9656177
[TBL] [Abstract][Full Text] [Related]
19. An implantable strain measurement system designed to detect spine fusion: preliminary results from a biomechanical in vivo study.
Szivek JA; Roberto RF; Slack JM; Majeed BS
Spine (Phila Pa 1976); 2002 Mar; 27(5):487-97. PubMed ID: 11880834
[TBL] [Abstract][Full Text] [Related]
20. Dual photon absorptiometry using a gadolinium-153 source applied to measure equine bone mineral content.
Moure A; Reichmann P; Gamba HR
Phys Med Biol; 2003 Dec; 48(23):3851-63. PubMed ID: 14703162
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]