BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 14524769)

  • 1. Photon correlation spectroscopy with high-energy coherent x rays.
    Thurn-Albrecht T; Zontone F; Grübel G; Steffen W; Müller-Buschbaum P; Patkowski A
    Phys Rev E Stat Nonlin Soft Matter Phys; 2003 Sep; 68(3 Pt 1):031407. PubMed ID: 14524769
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of real and imaginary form factors of silver atom using a high resolution HPGe detector.
    Krishnananda ; Niranjana KM; Badiger NM
    J Xray Sci Technol; 2013; 21(4):557-65. PubMed ID: 24191992
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved x-ray spectroscopy with room temperature CZT detectors.
    Fritz SG; Shikhaliev PM; Matthews KL
    Phys Med Biol; 2011 Sep; 56(17):5735-51. PubMed ID: 21841213
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Are all photon radiations similar in large absorbers?--a comparison of electron spectra.
    Kellerer AM; Roos H
    Radiat Prot Dosimetry; 2005; 113(3):245-50. PubMed ID: 15695239
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A K edge filter technique for optimization of the coherent-to-Compton scatter ratio method.
    Harding G; Armstrong R; McDaid S; Cooper MJ
    Med Phys; 1995 Dec; 22(12):2007-14. PubMed ID: 8746705
    [TBL] [Abstract][Full Text] [Related]  

  • 6. XAFS experiments at beamline I811, MAX-lab synchrotron source, Sweden.
    Carlson S; Clausén M; Gridneva L; Sommarin B; Svensson C
    J Synchrotron Radiat; 2006 Sep; 13(Pt 5):359-64. PubMed ID: 16924131
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Generation of high-photon flux-coherent soft x-ray radiation with few-cycle pulses.
    Demmler S; Rothhardt J; Hädrich S; Krebs M; Hage A; Limpert J; Tünnermann A
    Opt Lett; 2013 Dec; 38(23):5051-4. PubMed ID: 24281507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Possibility of single biomolecule imaging with coherent amplification of weak scattering x-ray photons.
    Shintake T
    Phys Rev E Stat Nonlin Soft Matter Phys; 2008 Oct; 78(4 Pt 1):041906. PubMed ID: 18999454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV.
    Vieira AA; Linke A; Yoshimura EM; Terini RA; Herdade SB
    Appl Radiat Isot; 2011 Feb; 69(2):350-7. PubMed ID: 21074445
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging.
    Sarnelli A; Taibi A; Baldelli P; Gambaccini M; Bravin A
    Phys Med Biol; 2007 Jun; 52(11):3015-26. PubMed ID: 17505086
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Single shot spatial and temporal coherence properties of the SLAC Linac Coherent Light Source in the hard x-ray regime.
    Gutt C; Wochner P; Fischer B; Conrad H; Castro-Colin M; Lee S; Lehmkühler F; Steinke I; Sprung M; Roseker W; Zhu D; Lemke H; Bogle S; Fuoss PH; Stephenson GB; Cammarata M; Fritz DM; Robert A; Grübel G
    Phys Rev Lett; 2012 Jan; 108(2):024801. PubMed ID: 22324689
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reabsorption of soft x-ray emission at high x-ray free-electron laser fluences.
    Schreck S; Beye M; Sellberg JA; McQueen T; Laksmono H; Kennedy B; Eckert S; Schlesinger D; Nordlund D; Ogasawara H; Sierra RG; Segtnan VH; Kubicek K; Schlotter WF; Dakovski GL; Moeller SP; Bergmann U; Techert S; Pettersson LG; Wernet P; Bogan MJ; Harada Y; Nilsson A; Föhlisch A
    Phys Rev Lett; 2014 Oct; 113(15):153002. PubMed ID: 25375708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples.
    Fuchs O; Weinhardt L; Blum M; Weigand M; Umbach E; Bär M; Heske C; Denlinger J; Chuang YD; McKinney W; Hussain Z; Gullikson E; Jones M; Batson P; Nelles B; Follath R
    Rev Sci Instrum; 2009 Jun; 80(6):063103. PubMed ID: 19566192
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing the signal-to-noise ratio for X-ray photon correlation spectroscopy.
    Falus P; Lurio LB; Mochrie SG
    J Synchrotron Radiat; 2006 May; 13(Pt 3):253-9. PubMed ID: 16645251
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analytic model of energy-absorption response functions in compound X-ray detector materials.
    Yun S; Kim HK; Youn H; Tanguay J; Cunningham IA
    IEEE Trans Med Imaging; 2013 Oct; 32(10):1819-28. PubMed ID: 23744671
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new method for an improved determination of continuous photon fluence spectra for X-ray tube voltages up to 150 kV.
    Schneider T; Kramer HM
    Radiat Prot Dosimetry; 2006; 121(4):370-5. PubMed ID: 16822777
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Emission of fluorescent x-radiation from non-lead based shielding materials of protective clothing: a radiobiological problem?
    Schmid E; Panzer W; Schlattl H; Eder H
    J Radiol Prot; 2012 Sep; 32(3):N129-39. PubMed ID: 22809876
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the relationship between dose-, energy- and LET-response of thermoluminescent detectors.
    Olko P; Bilski P; El-Faramawy NA; Göksu HY; Kim JL; Kopec R; Waligórski MP
    Radiat Prot Dosimetry; 2006; 119(1-4):15-22. PubMed ID: 16644968
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.
    Shikhaliev PM
    Phys Med Biol; 2012 Mar; 57(6):1595-615. PubMed ID: 22398007
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Photon statistics and speckle visibility spectroscopy with partially coherent X-rays.
    Li L; Kwaśniewski P; Orsi D; Wiegart L; Cristofolini L; Caronna C; Fluerasu A
    J Synchrotron Radiat; 2014 Nov; 21(Pt 6):1288-95. PubMed ID: 25343797
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.