268 related articles for article (PubMed ID: 1452618)
1. Determination of urinary 3-methylhistidine by high-performance liquid chromatography with o-phthaldialdehyde precolumn derivatization.
Min S; Yisheng Y; Lu Y
J Chromatogr; 1992 Oct; 581(2):272-6. PubMed ID: 1452618
[TBL] [Abstract][Full Text] [Related]
2. Determination of d-amphetamine in biological samples using high-performance liquid chromatography after precolumn derivatization with o-phthaldialdehyde and 3-mercaptopropionic acid.
Bowyer JF; Clausing P; Newport GD
J Chromatogr B Biomed Appl; 1995 Apr; 666(2):241-50. PubMed ID: 7633600
[TBL] [Abstract][Full Text] [Related]
3. High-performance liquid chromatographic method for rapid and highly sensitive determination of histidine using postcolumn fluorescence detection with o-phthaldialdehyde.
Tateda N; Matsuhisa K; Hasebe K; Kitajima N; Miura T
J Chromatogr B Biomed Sci Appl; 1998 Nov; 718(2):235-41. PubMed ID: 9840433
[TBL] [Abstract][Full Text] [Related]
4. Measurement of total plasma and cerebrospinal fluid homocysteine by fluorescence following high-performance liquid chromatography and precolumn derivatization with o-phthaldialdehyde.
Hyland K; Bottiglieri T
J Chromatogr; 1992 Aug; 579(1):55-62. PubMed ID: 1447351
[TBL] [Abstract][Full Text] [Related]
5. Simple and sensitive determination of plasma N tau-methylhistidine by high-performance liquid chromatography using pre-column derivative formation with o-phthalaldehyde-2-mercaptoethanol.
Nagasawa T; Sakai T; Onodera R
J Chromatogr; 1991 May; 566(1):223-7. PubMed ID: 1885715
[TBL] [Abstract][Full Text] [Related]
6. Determination of histidine and 3-methylhistidine in physiological fluids by high-performance liquid chromatography.
Qureshi GA; Van den Berg S; Gutierrez A; Bergström J
J Chromatogr; 1984 Aug; 297():83-9. PubMed ID: 6490774
[TBL] [Abstract][Full Text] [Related]
7. Rapid high-performance liquid chromatography of 3-methylhistidine in human urine.
Minkler PE; Ingalls ST; Griffin RL; Hoppel CL
J Chromatogr; 1987 Jan; 413():33-42. PubMed ID: 3558687
[TBL] [Abstract][Full Text] [Related]
8. Determination of S-nitrosoglutathione in human and rat plasma by high-performance liquid chromatography with fluorescence and ultraviolet absorbance detection after precolumn derivatization with o-phthalaldehyde.
Tsikas D; Sandmann J; Holzberg D; Pantazis P; Raida M; Frölich JC
Anal Biochem; 1999 Aug; 273(1):32-40. PubMed ID: 10452796
[TBL] [Abstract][Full Text] [Related]
9. Validation of the determination of amino acids in plasma by high-performance liquid chromatography using automated pre-column derivatization with o-phthaldialdehyde.
Fekkes D; van Dalen A; Edelman M; Voskuilen A
J Chromatogr B Biomed Appl; 1995 Jul; 669(2):177-86. PubMed ID: 7581894
[TBL] [Abstract][Full Text] [Related]
10. High-performance liquid chromatographic analysis of amino acids in physiological fluids: on-line precolumn derivatization with o-phthaldialdehyde.
Fleury MO; Ashley DV
Anal Biochem; 1983 Sep; 133(2):330-5. PubMed ID: 6638497
[TBL] [Abstract][Full Text] [Related]
11. Determination of boronophenylalanine in biological samples using precolumn o-phthalaldehyde derivatization and reversed-phase high-performance liquid chromatography.
Di Pierro D; Lazzarino G; Pastore FS; Tavazzi B; Del Bolgia F; Amorini AM; Fazzina G; Giuffrè R
Anal Biochem; 2000 Sep; 284(2):301-6. PubMed ID: 10964413
[TBL] [Abstract][Full Text] [Related]
12. A sensitive and specific high performance liquid chromatographic assay for imidazole dipeptides and 3-methylhistidine in human muscle biopsies, serum and urine.
Teahon K; Rideout JM
Biomed Chromatogr; 1992; 6(1):16-9. PubMed ID: 1600369
[TBL] [Abstract][Full Text] [Related]
13. High-performance liquid chromatography-electrochemical detection of 3-methylhistidine in human urine.
Betto P; Ricciarello G; Pichini S; Dello Strologo L; Rizzoni G
J Chromatogr; 1992 Dec; 584(2):256-60. PubMed ID: 1484110
[TBL] [Abstract][Full Text] [Related]
14. High-performance liquid chromatographic determination of 2-aminoethylphosphonic acid and 2-amino-3-phosphonopropionic acid in seawater matrix using precolumn fluorescence derivatization with o-phthalaldehyde-ethanethiol.
Wang S; Deng Y; Liu B; Li X; Lin X; Yuan D; Ma J
J Chromatogr A; 2018 Oct; 1571():147-154. PubMed ID: 30119975
[TBL] [Abstract][Full Text] [Related]
15. High-performance liquid chromatographic analysis of baclofen in plasma and urine of man after precolumn extraction and derivatization with o-phthaldialdehyde.
Wuis EW; Dirks RJ; Vree TB; van der Kleyn E
J Chromatogr; 1985 Feb; 337(2):341-50. PubMed ID: 3988864
[TBL] [Abstract][Full Text] [Related]
16. [High performance liquid chromatographic determination of amino acids in brain by precolumn derivatization with o-phthaldialdehyde].
Ye WL
Sheng Li Xue Bao; 1988 Jun; 40(3):308-13. PubMed ID: 3187565
[No Abstract] [Full Text] [Related]
17. High performance liquid chromatographic assay of Amicar, epsilon-aminocaproic acid, in plasma and urine after pre-column derivatization with o-phthalaldehyde for fluorescence detection.
Lam S
Biomed Chromatogr; 1990 Jul; 4(4):175-7. PubMed ID: 2207382
[TBL] [Abstract][Full Text] [Related]
18. High-performance liquid chromatography of cystathionine, lanthionine and aminoethylcysteine using o-phthaldialdehyde precolumn derivatization.
Costa M; Pecci I; Pensa B; Fontana M; Cavallini D
J Chromatogr; 1989 May; 490(2):404-10. PubMed ID: 2768413
[No Abstract] [Full Text] [Related]
19. New aspects of the simultaneous analysis of amino acids and amines as their o-phthaldialdehyde derivatives by high-performance liquid chromatography. Analysis of wine, beer and vinegar.
Kutlán D; Molnár-Perl I
J Chromatogr A; 2003 Feb; 987(1-2):311-22. PubMed ID: 12613825
[TBL] [Abstract][Full Text] [Related]
20. Determination of Histamine by High-Performance Liquid Chromatography After Precolumn Derivatization with o-Phthalaldehyde-Sulfite.
Chen R; Deng Y; Yang L; Wang J; Xu F
J Chromatogr Sci; 2016 Apr; 54(4):547-53. PubMed ID: 26688564
[TBL] [Abstract][Full Text] [Related]