These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 1453189)

  • 1. A widely unappreciated cause of failure of an automatic noninvasive blood pressure monitor.
    Weinger MB; Scanlon TS; Miller L
    J Clin Monit; 1992 Oct; 8(4):291-4. PubMed ID: 1453189
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Evaluating error values of pressure measuring systems and their clinical relevance].
    Albrecht DM; Ragaller M
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 May; 31(1 Suppl):S2-5. PubMed ID: 8737531
    [No Abstract]   [Full Text] [Related]  

  • 3. Accuracy of the CNAP™ monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in pediatric patients weighing 20-40 kilograms.
    Kako H; Corridore M; Rice J; Tobias JD
    Paediatr Anaesth; 2013 Nov; 23(11):989-93. PubMed ID: 23565770
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Technical principles of blood pressure monitoring and possible sources of error].
    Billiet E; Colardyn F
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 May; 31(1 Suppl):S6-8. PubMed ID: 8737532
    [No Abstract]   [Full Text] [Related]  

  • 5. Accuracy of the CNAP monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in the prone position.
    Dewhirst E; Corridore M; Klamar J; Beebe A; Rice J; Barry N; Tobias JD
    J Clin Anesth; 2013 Jun; 25(4):309-13. PubMed ID: 23685101
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of instruments for noninvasive blood pressure monitoring of the wrist.
    Latman NS; Latman A
    Biomed Instrum Technol; 1997; 31(1):63-8. PubMed ID: 9051227
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function.
    Gratze G; Fortin J; Holler A; Grasenick K; Pfurtscheller G; Wach P; Schönegger J; Kotanko P; Skrabal F
    Comput Biol Med; 1998 Mar; 28(2):121-42. PubMed ID: 9684089
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients.
    Janelle GM; Gravenstein N
    Anesth Analg; 2006 Feb; 102(2):484-90. PubMed ID: 16428547
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Noninvasive blood pressure measurement in external counterpulsation].
    Wonka F; Werner D; Krinke HE; Funk R; Daniel WG
    Biomed Tech (Berl); 1997; 42 Suppl():472-3. PubMed ID: 9517243
    [No Abstract]   [Full Text] [Related]  

  • 10. Clinical evaluation of an automatic blood pressure controller during cardiac surgery.
    Meijers RH; Schmartz D; Cantraine FR; Barvais L; d'Hollander AA; Blom JA
    J Clin Monit; 1997 Jul; 13(4):261-8. PubMed ID: 9269620
    [TBL] [Abstract][Full Text] [Related]  

  • 11. BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability.
    Thomas SS; Nathan V; Zong C; Soundarapandian K; Shi X; Jafari R
    IEEE J Biomed Health Inform; 2016 Sep; 20(5):1291-300. PubMed ID: 26208369
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Continuous blood pressure monitoring during stress ECG].
    Barschdorff D; Erig M
    Biomed Tech (Berl); 1998 Mar; 43(3):34-9. PubMed ID: 9556929
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Continuous monitoring of the recurrent laryngeal nerve].
    Lamadé W; Brandner R; Brauer M; Hund E; Klar E; Herfarth C
    Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1055-7. PubMed ID: 9931788
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An unusual cause of an erroneous noninvasive blood pressure reading.
    Blue D; Hannallah M
    Anesthesiology; 1993 Jun; 78(6):1196-7. PubMed ID: 8512123
    [No Abstract]   [Full Text] [Related]  

  • 15. [How accurate is invasive blood pressure determination with fluid-filled pressure line systems?].
    Francke A; Wachsmuth H
    Anaesthesiol Reanim; 2000; 25(2):46-54. PubMed ID: 10816897
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Problems in carrying out baroreflex sensitivity measurements in clinical routine practice: practicability and complications].
    Schwick N; Seidl K; Hauer B; Polak S; Zahn R; Senges J
    Z Kardiol; 1997 Mar; 86(3):165-70. PubMed ID: 9173705
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of false arrhythmia alarms with emphasis on ventricular tachycardia.
    Rodrigues R; Couto P
    Physiol Meas; 2016 Aug; 37(8):1326-39. PubMed ID: 27454934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Hardware implementation in VT/VF detection algorithms for AED (automatic external defibrillators)].
    Tchoudovski I; von Wagner G; Bolz A
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():547-9. PubMed ID: 12465232
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep.
    Yiallourou SR; Walker AM; Horne RS
    Sleep; 2006 Aug; 29(8):1083-8. PubMed ID: 16944678
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Intraoperative neuromonitoring of the recurrent laryngeal nerve--routine use in thyroid gland surgery].
    Kienast A; Richter C; Neumann HJ
    Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1058-60. PubMed ID: 9931789
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.