These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 14551869)

  • 1. ESGE/ESGENA technical note on cleaning and disinfection.
    Rey JF; Kruse A; Neumann C; ;
    Endoscopy; 2003 Oct; 35(10):869-77. PubMed ID: 14551869
    [No Abstract]   [Full Text] [Related]  

  • 2. ESGE-ESGENA Guideline: cleaning and disinfection in gastrointestinal endoscopy.
    Beilenhoff U; Neumann CS; Rey JF; Biering H; Blum R; Cimbro M; Kampf B; Rogers M; Schmidt V; ; ;
    Endoscopy; 2008 Nov; 40(11):939-57. PubMed ID: 19009486
    [No Abstract]   [Full Text] [Related]  

  • 3. Guideline for the use of high-level disinfectants and sterilants for reprocessing of flexible gastrointestinal endoscopes.
    Society of Gastroenterology Nurses and Associates, Inc.
    Gastroenterol Nurs; 2000; 23(4):180-7. PubMed ID: 11310086
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Current status of cleaning and disinfection for gastrointestinal endoscopy in China: a survey of 122 endoscopy units.
    Zhang X; Kong J; Tang P; Wang S; Hyder Q; Sun G; Zhang R; Yang Y
    Dig Liver Dis; 2011 Apr; 43(4):305-8. PubMed ID: 21269894
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Guidelines for the use of high-level disinfectants and sterilants for reprocessing of flexible gastrointestinal endoscopes.
    Society of Gastroenterology Nurses and Associates, Inc
    Gastroenterol Nurs; 2004; 27(4):198-206. PubMed ID: 15326411
    [No Abstract]   [Full Text] [Related]  

  • 6. [Disinfection of endoscopes].
    Moscato U
    Ann Ig; 2000; 12(4 Suppl 2):133-54. PubMed ID: 11100564
    [No Abstract]   [Full Text] [Related]  

  • 7. Endoscope disinfection using chlorine dioxide in an automated washer-disinfector.
    Isomoto H; Urata M; Kawazoe K; Matsuda J; Nishi Y; Wada A; Ohnita K; Hirakata Y; Matsuo N; Inoue K; Hirayama T; Kamihira S; Kohno S
    J Hosp Infect; 2006 Jul; 63(3):298-305. PubMed ID: 16650506
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sporicidal activity of disinfectants as one possible cause for bacteria in patient-ready endoscopes.
    Miner N; Harris V; Ebron T; Cao TD
    Gastroenterol Nurs; 2007; 30(4):285-90. PubMed ID: 17724404
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Regulatory aspects of disinfection of endoscopes].
    Salomon V; Touratier S
    Ann Chir; 1999; 53(10):954-9. PubMed ID: 10670140
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Disinfection in endoscopy.
    Fraise AP
    Lancet; 1995 Sep; 346(8978):787-8. PubMed ID: 7674739
    [No Abstract]   [Full Text] [Related]  

  • 11. ESGE-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy.
    Beilenhoff U; Neumann CS; Rey JF; Biering H; Blum R; Schmidt V;
    Endoscopy; 2007 Feb; 39(2):175-81. PubMed ID: 17327980
    [No Abstract]   [Full Text] [Related]  

  • 12. Importance of cleaning for reprocessing endoscopes and thermolabile sterile medical devices: French use and regulations.
    Darbord JC
    J Hosp Infect; 2004 Apr; 56 Suppl 2():S40-3. PubMed ID: 15110121
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Sterilization of Gastrointestinal Endoscope in Medical Institutions in Fukuoka Prefecture].
    Kumagai S; Watanabe H
    Sangyo Eiseigaku Zasshi; 2017 Oct; 59(5):149-152. PubMed ID: 28819081
    [No Abstract]   [Full Text] [Related]  

  • 14. Evaluation of the effectiveness of an enzymatic cleaner and glutaraldehyde-based disinfectant for chemothermal processing of flexible endoscopes in washer-disinfectors in accordance with prEN ISO 15 883.
    Zühlsdorf B; Kampf G
    Endoscopy; 2006 Jun; 38(6):586-91. PubMed ID: 16612746
    [TBL] [Abstract][Full Text] [Related]  

  • 15. ESGE/ESGENA guideline for process validation and routine testing for reprocessing endoscopes in washer-disinfectors, according to the European Standard prEN ISO 15883 parts 1, 4 and 5.
    Beilenhoff U; Neumann CS; Biering H; Blum R; Schmidt V; Rey JF; ;
    Endoscopy; 2007 Jan; 39(1):85-94. PubMed ID: 17252467
    [No Abstract]   [Full Text] [Related]  

  • 16. Cleaning and disinfection of flexible fiberoptic endoscopes (FFE) used in gastrointestinal endoscopy.
    Hedrick E
    APIC; 1978 Dec; 6(4):8-9. PubMed ID: 10239938
    [No Abstract]   [Full Text] [Related]  

  • 17. Processing flexible endoscopes: glutaraldehyde and the STERIS SYSTEM 1.
    Healthc Hazard Mater Manage; 1992 Jun; 5(9):7-10. PubMed ID: 10120246
    [No Abstract]   [Full Text] [Related]  

  • 18. Surface fixation of dried blood by glutaraldehyde and peracetic acid.
    Kampf G; Bloss R; Martiny H
    J Hosp Infect; 2004 Jun; 57(2):139-43. PubMed ID: 15183244
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reprocessing in digestive endoscopy units in Lombardy: results of a regional survey.
    Spinzi G; Fasoli R; Centenaro R; Minoli G;
    Dig Liver Dis; 2008 Nov; 40(11):890-6. PubMed ID: 18400569
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reprocessing endoscopes: United States perspective.
    Rutala WA; Weber DJ
    J Hosp Infect; 2004 Apr; 56 Suppl 2():S27-39. PubMed ID: 15110120
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.