These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 14562538)

  • 1. [Artifacts in MRT caused by instruments and implants].
    Graf H; Lauer UA; Klemm T; Schnieder L; Schick F
    Z Med Phys; 2003; 13(3):165-70. PubMed ID: 14562538
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Magnetic resonance imaging in cadaver dogs with metallic vertebral implants at 3 Tesla: evaluation of the WARP-turbo spin echo sequence.
    Griffin JF; Archambault NS; Mankin JM; Wall CR; Thompson JA; Padua A; Purdy D; Kerwin SC
    Spine (Phila Pa 1976); 2013 Nov; 38(24):E1548-53. PubMed ID: 23921320
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: dependence on field strength (1.5 and 3 T) and imaging parameters.
    Olsrud J; Lätt J; Brockstedt S; Romner B; Björkman-Burtscher IM
    J Magn Reson Imaging; 2005 Sep; 22(3):433-7. PubMed ID: 16104008
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Minimizing artefacts of metallic instruments and implants in MRI].
    Lauer UA; Klemm T; Graf H; Duda S; Claussen CD; Schick F
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():455-7. PubMed ID: 12451891
    [No Abstract]   [Full Text] [Related]  

  • 5. Metal artifacts caused by gradient switching.
    Graf H; Steidle G; Martirosian P; Lauer UA; Schick F
    Magn Reson Med; 2005 Jul; 54(1):231-4. PubMed ID: 15968663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: plates and screws.
    Zou YF; Chu B; Wang CB; Hu ZY
    Eur J Radiol; 2015 Mar; 84(3):450-457. PubMed ID: 25544555
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Metallic artifacts in magnetic resonance imaging of patients with spinal fusion. A comparison of implant materials and imaging sequences.
    Rudisch A; Kremser C; Peer S; Kathrein A; Judmaier W; Daniaux H
    Spine (Phila Pa 1976); 1998 Mar; 23(6):692-9. PubMed ID: 9549791
    [TBL] [Abstract][Full Text] [Related]  

  • 8. RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study.
    Graf H; Lauer UA; Berger A; Schick F
    Magn Reson Imaging; 2005 Apr; 23(3):493-9. PubMed ID: 15862651
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies.
    Suh JS; Jeong EK; Shin KH; Cho JH; Na JB; Kim DH; Han CD
    AJR Am J Roentgenol; 1998 Nov; 171(5):1207-13. PubMed ID: 9798849
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reduction of metal artefacts in musculoskeletal MR imaging.
    Vandevenne JE; Vanhoenacker FM; Parizel PM; Butts Pauly K; Lang RK
    JBR-BTR; 2007; 90(5):345-9. PubMed ID: 18085188
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.
    Wiens CN; Artz NS; Jang H; McMillan AB; Koch KM; Reeder SB
    Magn Reson Med; 2018 Apr; 79(4):2156-2163. PubMed ID: 28833407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radio frequency versus susceptibility effects of small conductive implants--a systematic MRI study on aneurysm clips at 1.5 and 3 T.
    Lauer UA; Graf H; Berger A; Claussen CD; Schick F
    Magn Reson Imaging; 2005 May; 23(4):563-9. PubMed ID: 15919602
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aneurysm clip MR artifacts. Titanium versus stainless steel and influence of imaging parameters.
    Burtscher IM; Owman T; Romner B; Ståhlberg F; Holtås S
    Acta Radiol; 1998 Jan; 39(1):70-6. PubMed ID: 9498874
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Motion and image artifacts of various intracranial aneurysm clips in a magnetic field.
    Ooka K; Shibuya M; Suzuki Y
    Acta Neurochir (Wien); 1996; 138(10):1241-5. PubMed ID: 8955445
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT.
    Lee MJ; Kim S; Lee SA; Song HT; Huh YM; Kim DH; Han SH; Suh JS
    Radiographics; 2007; 27(3):791-803. PubMed ID: 17495293
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging.
    Ai T; Padua A; Goerner F; Nittka M; Gugala Z; Jadhav S; Trelles M; Johnson RF; Lindsey RW; Li X; Runge VM
    Invest Radiol; 2012 May; 47(5):267-76. PubMed ID: 22266987
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Systematics of imaging artifacts in MRT caused by metallic vascular implants (stents)].
    Graf H; Klemm T; Lauer UA; Duda S; Claussen CD; Schick F
    Rofo; 2003 Dec; 175(12):1711-9. PubMed ID: 14661144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improving MR Image Quality in Patients with Metallic Implants.
    Lee EM; Ibrahim EH; Dudek N; Lu JC; Kalia V; Runge M; Srinivasan A; Stojanovska J; Agarwal PP
    Radiographics; 2021; 41(4):E126-E137. PubMed ID: 34143712
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging.
    Wiens CN; Artz NS; Jang H; McMillan AB; Reeder SB
    Magn Reson Med; 2017 Jun; 77(6):2303-2309. PubMed ID: 27403613
    [TBL] [Abstract][Full Text] [Related]  

  • 20. View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application.
    Jungmann PM; Ganter C; Schaeffeler CJ; Bauer JS; Baum T; Meier R; Nittka M; Pohlig F; Rechl H; von Eisenhart-Rothe R; Rummeny EJ; Woertler K
    PLoS One; 2015; 10(4):e0124922. PubMed ID: 25909472
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.