BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 14565005)

  • 1. [Theoretical analysis and numerical simulation of effect of steel plate positions on steel plate rigidity in internal fixation of bone surgery].
    Chen B; Gu Y; Lü D; Lü X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Sep; 20(3):425-9. PubMed ID: 14565005
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Less rigid internal fixation plates: historical perspectives and new concepts.
    Woo SL; Lothringer KS; Akeson WH; Coutts RD; Woo YK; Simon BR; Gomez MA
    J Orthop Res; 1984; 1(4):431-49. PubMed ID: 6491792
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis.
    Gautier E; Perren SM; Cordey J
    Injury; 2000 Sep; 31 Suppl 3():C14-20. PubMed ID: 11052376
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of carbon fibre composite fracture fixation plate using finite element analysis.
    Saidpour SH
    Ann Biomed Eng; 2006 Jul; 34(7):1157-63. PubMed ID: 16732432
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidity.
    Claes L
    J Orthop Res; 1989; 7(2):170-7. PubMed ID: 2918416
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new approach to the design of internal fixation plates.
    Woo SL; Simon BR; Akeson WH; Gomez MA; Seguchi Y
    J Biomed Mater Res; 1983 May; 17(3):427-39. PubMed ID: 6863347
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone.
    Fouad H
    Med Eng Phys; 2010 Sep; 32(7):783-9. PubMed ID: 20627657
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of plate-screw systems used in mandibular fracture reduction: finite element analysis.
    Lovald ST; Khraishi T; Wagner J; Baack B; Kelly J; Wood J
    J Biomech Eng; 2006 Oct; 128(5):654-62. PubMed ID: 16995751
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Analysis and experimental study of reasons for breakage in the bone fracture plate during internal fixation].
    Luo M; Feng Z; Tang G; Ma H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Sep; 18(3):428-31. PubMed ID: 11605508
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of fracture gap on stability of compression plate fixation: a finite element study.
    Oh JK; Sahu D; Ahn YH; Lee SJ; Tsutsumi S; Hwang JH; Jung DY; Perren SM; Oh CW
    J Orthop Res; 2010 Apr; 28(4):462-7. PubMed ID: 19862799
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates.
    Ganesh VK; Ramakrishna K; Ghista DN
    Biomed Eng Online; 2005 Jul; 4():46. PubMed ID: 16045807
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of bone plate with low-stiffness material in terms of stress distribution.
    Benli S; Aksoy S; Havitcioğlu H; Kucuk M
    J Biomech; 2008 Nov; 41(15):3229-35. PubMed ID: 18805533
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture.
    Cheng HY; Lin CL; Lin YH; Chen AC
    Clin Biomech (Bristol, Avon); 2007 Jun; 22(5):510-7. PubMed ID: 17328995
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures.
    Schwartz A; Oka R; Odell T; Mahar A
    Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):950-5. PubMed ID: 16782245
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of the helical plate for bone fracture fixation.
    Krishna KR; Sridhar I; Ghista DN
    Injury; 2008 Dec; 39(12):1421-36. PubMed ID: 18823624
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Biomechanic study on length of plate in treatment of tibial shaft fracture].
    Hu X; Yang S; Xiao D; Lin B; Wang H; Xu Z; Zhao W; Zhang M
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Nov; 22(11):1323-6. PubMed ID: 19068599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Comparative experimental studies on reconstructive miniplates].
    Schmid W; Pape HD
    Dtsch Z Mund Kiefer Gesichtschir; 1991; 15(4):271-4. PubMed ID: 1816957
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bone ingrowth and stress shielding with a porous surface coated fracture fixation plate.
    Pilliar RM; Cameron HU; Binnington AG; Szivek J; Macnab I
    J Biomed Mater Res; 1979 Sep; 13(5):799-810. PubMed ID: 383716
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling.
    Fouad H
    Med Eng Phys; 2011 May; 33(4):456-63. PubMed ID: 21146439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA: part 3: inferior and anterior repositioning surgery.
    Erkmen E; Ataç MS; Yücel E; Kurt A
    Int J Oral Maxillofac Surg; 2009 Feb; 38(2):173-9. PubMed ID: 19046852
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.