These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 14566106)

  • 41. Elevated Peak Systolic Velocity and Velocity Ratio from Duplex Ultrasound are Associated with Hemodynamically Significant Lesions in Arteriovenous Access.
    Plato SA; Kudlaty EA; Allemang MT; Kendrick DE; Wong VL; Wang JC; Kashyap VS
    Ann Vasc Surg; 2016 Aug; 35():68-74. PubMed ID: 27263815
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Vascular access surveillance: an ongoing controversy.
    Paulson WD; Moist L; Lok CE
    Kidney Int; 2012 Jan; 81(2):132-42. PubMed ID: 21975864
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Access flow measurement as a predictor of hemodialysis graft thrombosis: making clinical decisions.
    Krivitski NM; Gantela S
    Semin Dial; 2001; 14(3):181-5. PubMed ID: 11422924
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Stenosis detection with MR angiography and digital subtraction angiography in dysfunctional hemodialysis access fistulas and grafts.
    Froger CL; Duijm LE; Liem YS; Tielbeek AV; Donkers-van Rossum AB; Douwes-Draaijer P; Cuypers PW; Buth J; van den Bosch HC
    Radiology; 2005 Jan; 234(1):284-91. PubMed ID: 15618386
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Preprocedure Evaluation of a Dysfunctional Dialysis Access.
    Quencer KB; Kidd J; Kinney T
    Tech Vasc Interv Radiol; 2017 Mar; 20(1):20-30. PubMed ID: 28279406
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis.
    Tessitore N; Bedogna V; Gammaro L; Lipari G; Poli A; Baggio E; Firpo M; Morana G; Mansueto G; Maschio G
    Am J Kidney Dis; 2003 Aug; 42(2):331-41. PubMed ID: 12900816
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Value of static venous pressure for predicting arteriovenous graft thrombosis.
    Dember LM; Holmberg EF; Kaufman JS
    Kidney Int; 2002 May; 61(5):1899-904. PubMed ID: 11967043
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Assessment of sonographic venous peak systolic velocity in detecting hemodialysis arteriovenous graft stenosis.
    DeVita MV; Ky AJ; Fried KO; Vogel FE; Michelis MF
    Am J Kidney Dis; 2000 Oct; 36(4):797-803. PubMed ID: 11007683
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Outcomes of arteriovenous fistulas and grafts with or without intervention before successful use.
    Harms JC; Rangarajan S; Young CJ; Barker-Finkel J; Allon M
    J Vasc Surg; 2016 Jul; 64(1):155-62. PubMed ID: 27066945
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Impact of duplex ultrasound surveillance program on patency of prosthetic arteriovenous graft for hemodialysis: a single-center experience.
    Mauro R; Pini R; Faggioli G; Donati G; Facchini MG; D'Amico R; Freyrie A; Gargiulo M; Stella A
    Ann Vasc Surg; 2015 Aug; 29(6):1211-7. PubMed ID: 26009478
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Should current criteria for detecting and repairing arteriovenous fistula stenosis be reconsidered? Interim analysis of a randomized controlled trial.
    Tessitore N; Bedogna V; Poli A; Lipari G; Pertile P; Baggio E; Contro A; Criscenti P; Mansueto G; Lupo A
    Nephrol Dial Transplant; 2014 Jan; 29(1):179-87. PubMed ID: 24166470
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Primary balloon angioplasty plus balloon angioplasty maturation to upgrade small-caliber veins (<3 mm) for arteriovenous fistulas.
    De Marco Garcia LP; Davila-Santini LR; Feng Q; Calderin J; Krishnasastry KV; Panetta TF
    J Vasc Surg; 2010 Jul; 52(1):139-44. PubMed ID: 20471767
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Pro: Vascular access surveillance in mature fistulas: is it worthwhile?
    Tessitore N; Poli A
    Nephrol Dial Transplant; 2019 Jul; 34(7):1102-1106. PubMed ID: 30768204
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Sonography of Arteriovenous Fistulas and Grafts.
    Pietryga JA; Little MD; Robbin ML
    Semin Dial; 2017 Jul; 30(4):309-318. PubMed ID: 28393400
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Vascular dialysis access flow measurement: early intervention through early detection.
    Miguel SS; Chow J
    J Ren Care; 2009 Dec; 35(4):185-91. PubMed ID: 19909411
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: a controlled cohort study.
    Tessitore N; Bedogna V; Poli A; Mantovani W; Lipari G; Baggio E; Mansueto G; Lupo A
    Nephrol Dial Transplant; 2008 Nov; 23(11):3578-84. PubMed ID: 18511608
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Predicting hemodialysis access failure with color flow Doppler ultrasound.
    Bay WH; Henry ML; Lazarus JM; Lew NL; Ling J; Lowrie EG
    Am J Nephrol; 1998; 18(4):296-304. PubMed ID: 9653833
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Why do grafts clot despite access blood flow surveillance?
    Arbabzadeh M; Mepani B; Murray BM
    Cardiovasc Intervent Radiol; 2002; 25(6):501-5. PubMed ID: 12415418
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Permanent hemodialysis vascular access survival in children and adolescents with end-stage renal disease.
    Sheth RD; Brandt ML; Brewer ED; Nuchtern JG; Kale AS; Goldstein SL
    Kidney Int; 2002 Nov; 62(5):1864-9. PubMed ID: 12371990
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Evaluating patency rates of an ultralow-porosity expanded polytetrafluoroethylene covered stent in the treatment of venous stenosis in arteriovenous dialysis circuits.
    Chan MG; Miller FJ; Valji K; Bansal A; Kuo MD
    J Vasc Interv Radiol; 2014 Feb; 25(2):183-9. PubMed ID: 24286940
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.