These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 14566752)

  • 1. Dissemination of metals from a failed patellar component made of titanium-base alloy.
    Takai S; Yoshino N; Kusaka Y; Watanabe Y; Hirasawa Y
    J Arthroplasty; 2003 Oct; 18(7):931-5. PubMed ID: 14566752
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Metallosis in cemented titanium alloy total knee arthroplasty without apparent metal-on-metal articulation.
    Ho J; Mahajan J; Taylor M; Byers A; Arauz P; Kwon YM
    Knee; 2018 Aug; 25(4):728-731. PubMed ID: 29776814
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Serum titanium level for diagnosis of a failed, metal-backed patellar component.
    Leopold SS; Berger RA; Patterson L; Skipor AK; Urban RM; Jacobs JJ
    J Arthroplasty; 2000 Oct; 15(7):938-43. PubMed ID: 11061457
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Isolated metal-backed patellar component revision following total knee arthroplasty.
    Chan WH; Yeo SJ; Lee BP; Tay BK; Tan SK
    Singapore Med J; 1998 Jul; 39(7):303-5. PubMed ID: 9885691
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metal release and excretion from cementless titanium alloy total knee replacements.
    Jacobs JJ; Silverton C; Hallab NJ; Skipor AK; Patterson L; Black J; Galante JO
    Clin Orthop Relat Res; 1999 Jan; (358):173-80. PubMed ID: 9973989
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Titanium prosthetic wear debris in remote bone marrow. A report of two cases.
    Engh CA; Moore KD; Vinh TN; Engh GA
    J Bone Joint Surg Am; 1997 Nov; 79(11):1721-5. PubMed ID: 9384432
    [No Abstract]   [Full Text] [Related]  

  • 7. Wear in total knee arthroplasty--just a question of polyethylene?: Metal ion release in total knee arthroplasty.
    Kretzer JP; Reinders J; Sonntag R; Hagmann S; Streit M; Jeager S; Moradi B
    Int Orthop; 2014 Feb; 38(2):335-40. PubMed ID: 24218115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces.
    Feng EL; Stulberg SD; Wixson RL
    Clin Orthop Relat Res; 1994 Feb; (299):60-71. PubMed ID: 8119038
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis.
    Fabry C; Zietz C; Baumann A; Ehall R; Bader R
    Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2630-2639. PubMed ID: 28528349
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fracture of the polyethylene tibial post in a posterior cruciate-substituting total knee arthroplasty mimicking patellar clunk syndrome: a report of 5 cases.
    Mauerhan DR
    J Arthroplasty; 2003 Oct; 18(7):942-5. PubMed ID: 14566754
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Metallosis following knee arthroplasty: a histological and immunohistochemical study.
    Schiavone Panni A; Vasso M; Cerciello S; Maccauro G
    Int J Immunopathol Pharmacol; 2011; 24(3):711-9. PubMed ID: 21978703
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metal-backed patellar component failure in total knee arthroplasty presenting as a giant calf mass.
    Chang FY; Tseng KF; Chen WM; Huang CK; Chen TH; Lo WH
    J Arthroplasty; 2003 Feb; 18(2):227-30. PubMed ID: 12629618
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Titanemia from total knee arthroplasty. A case resulting from a failed patellar component.
    von Schroeder HP; Smith DC; Gross AE; Pilliar RM; Kandel RA; Chernecky R; Lugowski SJ
    J Arthroplasty; 1996 Aug; 11(5):620-5. PubMed ID: 8872586
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of patellofemoral design on patellofemoral forces and polyethylene stresses.
    D'Lima DD; Chen PC; Kester MA; Colwell CW
    J Bone Joint Surg Am; 2003; 85-A Suppl 4():85-93. PubMed ID: 14652397
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fate of the unrevised all-polyethylene patellar component in revision total knee arthroplasty.
    Lonner JH; Mont MA; Sharkey PF; Siliski JM; Rajadhyaksha AD; Lotke PA
    J Bone Joint Surg Am; 2003 Jan; 85(1):56-9. PubMed ID: 12533572
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Isolated revision of failed metal-backed patellar components: outcome with minimum 4-year follow-up.
    Burke WV; Ammeen DJ; Engh GA
    J Arthroplasty; 2005 Dec; 20(8):998-1001. PubMed ID: 16376254
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyethylene failure of the patellar component in New Jersey low-contact stress total knee arthroplasties.
    Huang CH; Liau JJ; Ho FY; Lin CY; Young TH; Cheng CK
    J Arthroplasty; 2005 Feb; 20(2):202-8. PubMed ID: 15902859
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications.
    Gaillard R; Lustig S; Peltier A; Villa V; Servien E; Neyret P
    Orthop Traumatol Surg Res; 2016 Dec; 102(8):1061-1068. PubMed ID: 27771429
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Metallosis: A Rare Cause of Autoimmune Hemolytic Anemia].
    Duarte J; Correia L; Simão A; Figueiredo A; Carvalho A
    Acta Med Port; 2015; 28(3):386-9. PubMed ID: 26421793
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Posterior condyle surface damage on retrieved femoral knee components.
    Burnell CD; Brandt JM; Petrak MJ; Bourne RB
    J Arthroplasty; 2011 Dec; 26(8):1460-7. PubMed ID: 21570806
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.