  • 1. Novel, adjustable, clinical bymixer measures mixed expired gas concentrations in anesthesia circle circuit.
    Rosenbaum A; Breen PH
    Anesth Analg; 2003 Nov; 97(5):1414-1420. PubMed ID: 14570659
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bymixer system can measure O2 uptake and CO2 elimination in the anesthesia circle circuit.
    Rosenbaum A; Kirby CW; Breen PH
    Can J Anaesth; 2007 Jun; 54(6):430-40. PubMed ID: 17541071
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.
    Rosenbaum A; Kirby C; Breen PH
    Anesthesiology; 2004 Jun; 100(6):1427-37. PubMed ID: 15166562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bymixer provides on-line calibration of measurement of CO2 volume exhaled per breath.
    Breen PH; Serina ER
    Ann Biomed Eng; 1997; 25(1):164-71. PubMed ID: 9124730
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A small bypass mixing chamber for monitoring metabolic rate and anesthetic uptake: the bymixer.
    Sanjo Y; Ikeda K
    J Clin Monit; 1987 Oct; 3(4):235-43. PubMed ID: 3119784
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The most proximal and accurate site for sampling end-tidal CO2 in infants.
    Halpern L; Bissonnette B
    Can J Anaesth; 1994 Oct; 41(10):984-90. PubMed ID: 8001218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rebreathing improves accuracy of ventilatory monitoring.
    Bowie JR; Knox P; Downs JB; Smith RA
    J Clin Monit; 1995 Nov; 11(6):354-7. PubMed ID: 8576717
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel portable device measures preoperative patient metabolic gas exchange.
    Rosenbaum A; Howard HC; Breen PH
    Anesth Analg; 2008 Feb; 106(2):509-16, table of contents. PubMed ID: 18227307
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction of fresh gas flow requirements by a circle-modified bain breathing circuit.
    Valdrighi JB; Nance PN
    J Clin Monit; 1991 Jan; 7(1):49-55. PubMed ID: 1900324
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Special aspects of pharmacokinetics of inhalation anesthesia.
    Hendrickx JF; De Wolf A
    Handb Exp Pharmacol; 2008; (182):159-86. PubMed ID: 18175091
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [PhysioFlex: a target-controlled self-regulating closed-circuit inhalation anesthesia regulator].
    Nathan N; Sperandio M; Erdmann W; Westerkamp B; Van Dijk G; Scherpereel P; Feiss P
    Ann Fr Anesth Reanim; 1997; 16(5):534-40. PubMed ID: 9750610
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo validation of the M-COVX metabolic monitor in patients under anaesthesia.
    Stuart-Andrews CR; Peyton P; Robinson GJ; Terry D; O'Connor B; Van der Herten C; Lithgow B
    Anaesth Intensive Care; 2007 Jun; 35(3):398-405. PubMed ID: 17591136
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Positive end-expiratory pressure: implications for tidal volume changes in anesthesia machine ventilation.
    Elliott WR; Harris AE; Philip JH
    J Clin Monit; 1989 Apr; 5(2):100-4. PubMed ID: 2656922
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Carbon dioxide spirogram (but not capnogram) detects leaking inspiratory valve in a circle circuit.
    Breen PH; Jacobsen BP
    Anesth Analg; 1997 Dec; 85(6):1372-6. PubMed ID: 9390611
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of oxygen uptake in the non-steady-state.
    Powers SK; Lawler J; Thompson D; Beadle R
    Aviat Space Environ Med; 1987 Apr; 58(4):323-7. PubMed ID: 3579818
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Anesthesia with the closed PhysioFlex system in comparison with conventional anesthesia procedures].
    Hargasser S; Breinbauer B; Kling M; Mielke L; Entholzner E; Malek A; Rust M; Hipp R
    Anaesthesiol Reanim; 1994; 19(6):149-54. PubMed ID: 7865063
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Estimating the Impact of Carbon Dioxide Absorbent Performance Differences on Absorbent Cost During Low-Flow Anesthesia.
    Feldman JM; Lo C; Hendrickx J
    Anesth Analg; 2020 Feb; 130(2):374-381. PubMed ID: 30925559
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a new mixing chamber system for breath-by-breath indirect calorimetry.
    Kim DY; Robergs RA
    Appl Physiol Nutr Metab; 2012 Feb; 37(1):157-66. PubMed ID: 22300357
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physical characteristics of an enclosed afferent reservoir breathing system.
    Jennings AD; Michell BC; Beatty PC; Meakin G; Healy TE
    Br J Anaesth; 1992 Jun; 68(6):625-9. PubMed ID: 1344024
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New metabolic lung simulator: development, description, and validation.
    Rosenbaum A; Kirby C; Breen PH
    J Clin Monit Comput; 2007 Apr; 21(2):71-82. PubMed ID: 17333487
    [TBL] [Abstract][Full Text] [Related]  