254 related articles for article (PubMed ID: 14574407)
1. A broadband superconducting detector suitable for use in large arrays.
Day PK; LeDuc HG; Mazin BA; Vayonakis A; Zmuidzinas J
Nature; 2003 Oct; 425(6960):817-21. PubMed ID: 14574407
[TBL] [Abstract][Full Text] [Related]
2. Relative detection efficiency of back- and front-illuminated charge-coupled device cameras for X-rays between 1 keV and 18 keV.
Szlachetko J; Dousse JC; Hoszowska J; Berset M; Cao W; Szlachetko M; Kavcic M
Rev Sci Instrum; 2007 Sep; 78(9):093102. PubMed ID: 17902942
[TBL] [Abstract][Full Text] [Related]
3. Low light level detectors for astronomy.
Boyce PB
Science; 1977 Oct; 198(4313):145-8. PubMed ID: 17755344
[TBL] [Abstract][Full Text] [Related]
4. Energy-resolving X-ray fluorescence detection using synthetic multilayers.
Zhang K; Rosenbaum G; Bunker G
J Synchrotron Radiat; 1998 Jul; 5(Pt 4):1227-34. PubMed ID: 16687826
[TBL] [Abstract][Full Text] [Related]
5. Advanced mercuric iodide detectors for X-ray microanalysis.
Warburton WK; Iwanczyk JS
Scanning Microsc Suppl; 1987; 1():135-50. PubMed ID: 3481104
[TBL] [Abstract][Full Text] [Related]
6. CdZnTe array detectors for synchrotron radiation applications.
Yoo SS; Jennings G; Montano PA
J Synchrotron Radiat; 1998 Nov; 5(Pt 6):1332-6. PubMed ID: 16687845
[TBL] [Abstract][Full Text] [Related]
7. Flat field anomalies in an x-ray charge coupled device camera measured using a Manson x-ray source.
Haugh MJ; Schneider MB
Rev Sci Instrum; 2008 Oct; 79(10):10E925. PubMed ID: 19044580
[TBL] [Abstract][Full Text] [Related]
8. A superconducting focal plane array for ultraviolet, optical, and near-infrared astrophysics.
Mazin BA; Bumble B; Meeker SR; O'Brien K; McHugh S; Langman E
Opt Express; 2012 Jan; 20(2):1503-11. PubMed ID: 22274494
[TBL] [Abstract][Full Text] [Related]
9. Application of a pnCCD in X-ray diffraction: a three-dimensional X-ray detector.
Leitenberger W; Hartmann R; Pietsch U; Andritschke R; Starke I; Strüder L
J Synchrotron Radiat; 2008 Sep; 15(Pt 5):449-57. PubMed ID: 18728315
[TBL] [Abstract][Full Text] [Related]
10. A correlation between the cosmic microwave background and large-scale structure in the Universe.
Boughn S; Crittenden R
Nature; 2004 Jan; 427(6969):45-7. PubMed ID: 14702078
[TBL] [Abstract][Full Text] [Related]
11. A readout for large arrays of microwave kinetic inductance detectors.
McHugh S; Mazin BA; Serfass B; Meeker S; O'Brien K; Duan R; Raffanti R; Werthimer D
Rev Sci Instrum; 2012 Apr; 83(4):044702. PubMed ID: 22559560
[TBL] [Abstract][Full Text] [Related]
12. Imaging performance of the hybrid pixel detectors XPAD3-S.
Brunner FC; Clemens JC; Hemmer C; Morel C
Phys Med Biol; 2009 Mar; 54(6):1773-89. PubMed ID: 19258683
[TBL] [Abstract][Full Text] [Related]
13. Silicon drift and pixel devices for X-ray imaging and spectroscopy.
Lutz G
J Synchrotron Radiat; 2006 Mar; 13(Pt 2):99-109. PubMed ID: 16495610
[TBL] [Abstract][Full Text] [Related]
14. On the use of CCD area detectors for high-resolution specular X-ray reflectivity.
Fenter P; Catalano JG; Park C; Zhang Z
J Synchrotron Radiat; 2006 Jul; 13(Pt 4):293-303. PubMed ID: 16799220
[TBL] [Abstract][Full Text] [Related]
15. Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy.
Szypryt P; Meeker SR; Coiffard G; Fruitwala N; Bumble B; Ulbricht G; Walter AB; Daal M; Bockstiegel C; Collura G; Zobrist N; Lipartito I; Mazin BA
Opt Express; 2017 Oct; 25(21):25894-25909. PubMed ID: 29041252
[TBL] [Abstract][Full Text] [Related]
16. Compact pnCCD-based X-ray camera with high spatial and energy resolution: a color X-ray camera.
Scharf O; Ihle S; Ordavo I; Arkadiev V; Bjeoumikhov A; Bjeoumikhova S; Buzanich G; Gubzhokov R; Günther A; Hartmann R; Kühbacher M; Lang M; Langhoff N; Liebel A; Radtke M; Reinholz U; Riesemeier H; Soltau H; Strüder L; Thünemann AF; Wedell R
Anal Chem; 2011 Apr; 83(7):2532-8. PubMed ID: 21355541
[TBL] [Abstract][Full Text] [Related]
17. High-resolution hard x-ray spectroscopy of high-temperature plasmas using an array of quantum microcalorimeters.
Thorn DB; Gu MF; Brown GV; Beiersdorfer P; Porter FS; Kilbourne CA; Kelley RL
Rev Sci Instrum; 2008 Oct; 79(10):10E323. PubMed ID: 19044485
[TBL] [Abstract][Full Text] [Related]
18. Cryogenic X-ray detectors for synchrotron science.
Friedrich S
J Synchrotron Radiat; 2006 Mar; 13(Pt 2):159-71. PubMed ID: 16495616
[TBL] [Abstract][Full Text] [Related]
19. Calibration and application of an X-ray image intensifier/ charge-coupled device detector for monochromatic macromolecular crystallography.
Hammersley AP; Brown K; Burmeister W; Claustre L; Gonzalez A; McSweeney S; Mitchell E; Moy JP; Svensson SO; Thompson AW
J Synchrotron Radiat; 1997 Mar; 4(Pt 2):67-77. PubMed ID: 16699210
[TBL] [Abstract][Full Text] [Related]
20. Performance of the EBIT calorimeter spectrometer.
Porter FS; Gygax J; Kelley RL; Kilbourne CA; King JM; Beiersdorfer P; Brown GV; Thorn DB; Kahn SM
Rev Sci Instrum; 2008 Oct; 79(10):10E307. PubMed ID: 19044469
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]