377 related articles for article (PubMed ID: 14577011)
1. Clinical evaluation of stereotactic brain biopsies with an MKM-mounted instrument holder.
Willems PW; Noordmans HJ; Ramos LM; Taphoorn MJ; Berkelbach van der Sprenkel JW; Viergever MA; Tulleken CA
Acta Neurochir (Wien); 2003 Oct; 145(10):889-97; discussion 897. PubMed ID: 14577011
[TBL] [Abstract][Full Text] [Related]
2. Safety and efficacy of frameless and frame-based intracranial biopsy techniques.
Dammers R; Haitsma IK; Schouten JW; Kros JM; Avezaat CJ; Vincent AJ
Acta Neurochir (Wien); 2008 Jan; 150(1):23-9. PubMed ID: 18172567
[TBL] [Abstract][Full Text] [Related]
3. An MKM-mounted instrument holder for frameless point-stereotactic procedures: a phantom-based accuracy evaluation.
Willems PW; Noordmans HJ; Berkelbach van der Sprenkel JW; Viergever MA; Tulleken CA
J Neurosurg; 2001 Dec; 95(6):1067-74. PubMed ID: 11765825
[TBL] [Abstract][Full Text] [Related]
4. [Clinical analysis of 1434 cases of frameless stereotactic operation].
Tian ZM; Lu WS; Zhao QJ; Yu X; Xu YG; Wang R; Qi SB
Zhonghua Wai Ke Za Zhi; 2007 May; 45(10):702-4. PubMed ID: 17688826
[TBL] [Abstract][Full Text] [Related]
5. Frameless stereotactic brain biopsy procedures using the Stealth Station: indications, accuracy and results.
Gralla J; Nimsky C; Buchfelder M; Fahlbusch R; Ganslandt O
Zentralbl Neurochir; 2003; 64(4):166-70. PubMed ID: 14634881
[TBL] [Abstract][Full Text] [Related]
6. Stereotactic biopsies guided by an optical navigation system: technique and clinical experience.
Grunert P; Espinosa J; Busert C; Günthner M; Filippi R; Farag S; Hopf N
Minim Invasive Neurosurg; 2002 Mar; 45(1):11-5. PubMed ID: 11932818
[TBL] [Abstract][Full Text] [Related]
7. Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot.
Grimm F; Naros G; Gutenberg A; Keric N; Giese A; Gharabaghi A
J Neurosurg; 2015 Sep; 123(3):737-42. PubMed ID: 26067616
[TBL] [Abstract][Full Text] [Related]
8. Clinical experience with intracranial brain needle biopsy using frameless surgical navigation.
Germano IM; Queenan JV
Comput Aided Surg; 1998; 3(1):33-9. PubMed ID: 9699077
[TBL] [Abstract][Full Text] [Related]
9. [Clinical application of robotic tele-manipulation system in stereotactic surgery].
Tian ZM; Lu WS; Wang TM; Liu D; Chen Y; Zhang GL; Zhao QJ; Bai MM; Yin F
Zhonghua Wai Ke Za Zhi; 2007 Dec; 45(24):1679-81. PubMed ID: 18476525
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of single-time, multilevel registration in image-guided spinal surgery.
Papadopoulos EC; Girardi FP; Sama A; Sandhu HS; Cammisa FP
Spine J; 2005; 5(3):263-7; discussion 268. PubMed ID: 15863081
[TBL] [Abstract][Full Text] [Related]
11. Clinical introduction of an adjustable rigid instrument holder for frameless stereotactic interventions.
Dorward NL; Alberti O; Dijkstra A; Buurman J; Kitchen ND; Thomas DG
Comput Aided Surg; 1997; 2(3-4):180-5. PubMed ID: 9377719
[TBL] [Abstract][Full Text] [Related]
12. [MRI-guided stereotactic biopsy for questionable diseases in brain].
Zhang YQ; Zhao GG; Li KC; Li JY; Yu T; Wang L; Li YJ
Zhonghua Wai Ke Za Zhi; 2003 Sep; 41(9):667-9. PubMed ID: 14680565
[TBL] [Abstract][Full Text] [Related]
13. Correlation of diagnostic yield of stereotactic brain biopsy with number of biopsy bits and site of the lesion.
Jain D; Sharma MC; Sarkar C; Deb P; Gupta D; Mahapatra AK
Brain Tumor Pathol; 2006 Oct; 23(2):71-5. PubMed ID: 18095122
[TBL] [Abstract][Full Text] [Related]
14. [Stereotactic brain biopsy in the diagnosis of focal brain lesions in AIDS].
Corti M; Metta H; Villafañe MF; Yampolsky C; Schtirbu R; Sevlever G; Garrido D
Medicina (B Aires); 2008; 68(4):285-90. PubMed ID: 18786884
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note.
Dorward NL; Alberti O; Palmer JD; Kitchen ND; Thomas DG
J Neurosurg; 1999 Jan; 90(1):160-8. PubMed ID: 10413173
[TBL] [Abstract][Full Text] [Related]
16. The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems.
Li QH; Zamorano L; Pandya A; Perez R; Gong J; Diaz F
Comput Aided Surg; 2002; 7(2):90-8. PubMed ID: 12112718
[TBL] [Abstract][Full Text] [Related]
17. Frameless stereotactic targeting devices: technical features, targeting errors and clinical results.
Widmann G; Schullian P; Ortler M; Bale R
Int J Med Robot; 2012 Mar; 8(1):1-16. PubMed ID: 22076960
[TBL] [Abstract][Full Text] [Related]
18. Stereotactic biopsy in surgically inaccessible tumors with the use of "P.N." type frame.
Krzyszkowski T; Czepko R; Adamek D
Ann Acad Med Stetin; 2007; 53(1):27-32. PubMed ID: 18561607
[TBL] [Abstract][Full Text] [Related]
19. [Usefulness of the "P.N." frame in biopsies and stereotactic operations on the brain].
Krzyszkowski T; Czepko R; Adamek D; Kwinta B
Przegl Lek; 2004; 61(9):924-7. PubMed ID: 15803900
[TBL] [Abstract][Full Text] [Related]
20. [Complications and diagnostic yield of stereotactic biopsy for the patients with malignant brain tumors].
Takahashi H; Sugai T; Uzuka T; Kano M; Honma J; Grinev I; Tanaka R
No Shinkei Geka; 2004 Feb; 32(2):135-40. PubMed ID: 15031974
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]