These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 1457893)

  • 1. Subcutaneous capillary filtrate collector for measurement of blood glucose.
    Ash SR; Poulos JT; Rainier JB; Zopp WE; Janle E; Kissinger PT
    ASAIO J; 1992; 38(3):M416-20. PubMed ID: 1457893
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A subcutaneous capillary filtrate collector for measurement of blood chemistries.
    Ash SR; Rainier JB; Zopp WE; Truitt RB; Janle EM; Kissinger PT; Poulos JT
    ASAIO J; 1993; 39(3):M699-705. PubMed ID: 8268628
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effectiveness of continuous glucose monitoring in dialysis patients with diabetes: the DIALYDIAB pilot study.
    Joubert M; Fourmy C; Henri P; Ficheux M; Lobbedez T; Reznik Y
    Diabetes Res Clin Pract; 2015 Mar; 107(3):348-54. PubMed ID: 25638452
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Recording of subcutaneous glucose dynamics by a viscometric affinity sensor.
    Beyer U; Schäfer D; Thomas A; Aulich H; Haueter U; Reihl B; Ehwald R
    Diabetologia; 2001 Apr; 44(4):416-23. PubMed ID: 11357470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of a capillary filtrate collector for monitoring glucose in diabetics.
    Janle-Swain E; Van Vleet JF; Ash SR
    ASAIO Trans; 1987; 33(3):336-40. PubMed ID: 3675963
    [No Abstract]   [Full Text] [Related]  

  • 6. Institutional glucometrics to determine glucose control as practiced by general medicine wards.
    Buchs AE; Rapoport MJ
    Isr Med Assoc J; 2010 Aug; 12(8):463-7. PubMed ID: 21337813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endogenous factors modified by hemodialysis may interfere with the accuracy of blood glucose-measuring device.
    Ogawa T; Murakawa M; Matsuda A; Kanozawa K; Kato H; Hasegawa H; Mitarai T
    Hemodial Int; 2012 Apr; 16(2):266-73. PubMed ID: 22098760
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The evaluation of analytical performance of the Precision G point-of-care glucometer.
    Solnica B; Naskalski JW; Sieradzki J
    Clin Chem Lab Med; 2001 Dec; 39(12):1283-6. PubMed ID: 11798091
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lack of correlation of glucose levels in filtered blood plasma to density and conductivity measurements.
    Gordon DM; Ash SR
    ASAIO J; 2009; 55(3):227-30. PubMed ID: 19282748
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of glucose levels in dermal interstitial fluid and finger capillary blood.
    Stout PJ; Peled N; Erickson BJ; Hilgers ME; Racchini JR; Hoegh TB
    Diabetes Technol Ther; 2001; 3(1):81-90. PubMed ID: 11469711
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of hemodialysis membranes on the plasma insulin level of diabetic patients on maintenance hemodialysis.
    Abe M; Kikuchi F; Kaizu K; Matsumoto K
    Clin Nephrol; 2008 May; 69(5):354-60. PubMed ID: 18538098
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.
    Wagner JG; Schmidtke DW; Quinn CP; Fleming TF; Bernacky B; Heller A
    Proc Natl Acad Sci U S A; 1998 May; 95(11):6379-82. PubMed ID: 9600973
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Methods for measuring agreement: glucose levels in gingival crevice blood.
    Müller HP; Behbehani E
    Clin Oral Investig; 2005 Mar; 9(1):65-9. PubMed ID: 15635475
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies.
    Laffel L
    Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S223-33. PubMed ID: 26784126
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrafiltrate sampling device for continuous monitoring.
    Moscone D; Venema K; Korf J
    Med Biol Eng Comput; 1996 Jul; 34(4):290-4. PubMed ID: 8935495
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis.
    Meyerhoff C; Bischof F; Sternberg F; Zier H; Pfeiffer EF
    Diabetologia; 1992 Nov; 35(11):1087-92. PubMed ID: 1473620
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of lancets for pain perception and capillary blood volume for glucose monitoring.
    Warunek D; Stankovic AK
    Clin Lab Sci; 2008; 21(4):215-8. PubMed ID: 19174981
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of portable blood glucose monitoring. Effect of glucose level and prandial state.
    Vallera DA; Bissell MG; Barron W
    Am J Clin Pathol; 1991 Feb; 95(2):247-52. PubMed ID: 1992617
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Regulation of the blood sugar level by the artificial endocrine pancreas (Biostator GCIIS) during dialysis of a diabetic patient].
    Bojta J; Juhász J; Bányai Z; Makó J; Tamás G
    Orv Hetil; 1979 Dec; 120(51):3109-10. PubMed ID: 396497
    [No Abstract]   [Full Text] [Related]  

  • 20. [Home monitoring of blood glucose concentrations by owners of diabetic dogs and cats].
    Sieber-Ruckstuhl NS; Casella M; Reusch CE
    Schweiz Arch Tierheilkd; 2003 Nov; 145(11):537-43. PubMed ID: 14639824
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.