256 related articles for article (PubMed ID: 14579054)
21. Migration of retained right ventricular epicardial pacing wire into the pulmonary artery: a rare complication after heart surgery.
Worth PJ; Conklin P; Prince E; Singh AK
J Thorac Cardiovasc Surg; 2011 Sep; 142(3):e136-8. PubMed ID: 21719030
[No Abstract] [Full Text] [Related]
22. A successful percutaneous retrieval of a fractured pacemaker lead from a segmental pulmonary artery.
Guler A; Karabay CY; Aung SM; Pala S; Kirma C
Europace; 2012 Apr; 14(4):605. PubMed ID: 21969527
[TBL] [Abstract][Full Text] [Related]
23. [Complications after pacemaker-implantation and their treatment (author's transl)].
Klövekorn WP; Struck E; Sasa T
Herz; 1978 Dec; 63(36):357-61. PubMed ID: 400158
[TBL] [Abstract][Full Text] [Related]
24. Coronary sinus lead fragmentation 2 years after implantation with a retained guidewire.
Nägele H; Hashagen S; Ergin M; Azizi M; Behrens S
Pacing Clin Electrophysiol; 2007 Mar; 30(3):438-9. PubMed ID: 17367367
[TBL] [Abstract][Full Text] [Related]
25. [Successful removal of infected pacemaker leads under extracorporeal circulation in three cases].
Nishimura Y; Kajiwara T
Fukuoka Igaku Zasshi; 2007 Aug; 98(8):329-31. PubMed ID: 17907449
[TBL] [Abstract][Full Text] [Related]
26. Minimal invasive coronary sinus lead reposition technique for the treatment of phrenic nerve stimulation.
Szilágyi S; Merkely B; Zima E; Kutyifa V; Szucs G; Fülöp G; Molnár L; Szabolcs Z; Gellér L
Europace; 2008 Oct; 10(10):1157-60. PubMed ID: 18703584
[TBL] [Abstract][Full Text] [Related]
27. Successful percutaneous repositioning of a dislodged pacemaker lead.
Yoshida N; Yamada T; McElderry HT
Europace; 2014 Jan; 16(1):148. PubMed ID: 24092666
[No Abstract] [Full Text] [Related]
28. Spontaneous twisting of a pacemaker lead in an unusual site.
Cay S; Ozturk S; Korkmaz S
Pacing Clin Electrophysiol; 2005 Jul; 28(7):740-1. PubMed ID: 16008816
[TBL] [Abstract][Full Text] [Related]
29. [Twiddling with hands is forbidden!].
Füessl HS
MMW Fortschr Med; 2006 May; 148(18):22. PubMed ID: 16736680
[No Abstract] [Full Text] [Related]
30. Successful reimplantation of a passive-fixation ventricle lead perforating the chest wall.
Kur F; Beiras-Fernandez A; Kowert A; Schmoeckel M; Reichart B
Heart Surg Forum; 2008; 11(3):E137-9. PubMed ID: 18583281
[TBL] [Abstract][Full Text] [Related]
31. An unusual complication of a ventricular pace maker electrode.
Sassard T; Fareh S; Farhat F
Eur J Cardiothorac Surg; 2007 Feb; 31(2):306. PubMed ID: 17178229
[No Abstract] [Full Text] [Related]
32. Unexpected loss of atrial tracking caused by interaction between temporary and permanent right ventricular leads during implantation of a biventricular pacemaker.
Chang KC; Chen JY; Lin JJ; Hung JS
Pacing Clin Electrophysiol; 2004 Jul; 27(7):998-1001. PubMed ID: 15271023
[TBL] [Abstract][Full Text] [Related]
33. Incidental finding of migrated pacing lead fragment into pulmonary artery detected with CT.
Estornell-Erill J; Fabregat-Andrés O; Bochard-Villanueva B; Ridocci-Soriano F
J Cardiovasc Comput Tomogr; 2013; 7(2):136-7. PubMed ID: 23622509
[TBL] [Abstract][Full Text] [Related]
34. Successful conservative management with positive end-expiratory pressure for massive haemothorax complicating pacemaker implantation.
Lai CH; Chen JY; Wu HY; Wen JS; Yang YJ
Resuscitation; 2007 Oct; 75(1):189-91. PubMed ID: 17467866
[TBL] [Abstract][Full Text] [Related]
35. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion.
Chemelli AP; Chemelli-Steingruber IE; Bonaros N; Luckner G; Millonig G; Seppi K; Lottersberger C; Jaschke W
Eur J Radiol; 2009 Aug; 71(2):269-74. PubMed ID: 18534801
[TBL] [Abstract][Full Text] [Related]
36. [Cerebral embolism caused by a right ventricular pacemaker electrode perforated into the left atrium].
Bóhm A; Bányai F; Komáromy K; Pintér A; Préda I
Orv Hetil; 1997 Sep; 138(36):2235-7. PubMed ID: 9333733
[TBL] [Abstract][Full Text] [Related]
37. Percutaneous transcatheter repositioning of displaced permanent pacemaker atrial lead with a simple system.
Kursaklioglu H; Barcin C; Iyisoy A; Kose S; Isik E
Int J Cardiovasc Intervent; 2004; 6(2):88-90. PubMed ID: 15385209
[TBL] [Abstract][Full Text] [Related]
38. [Misplaced implantation of a pacemaker electrode in a coronary vein].
Möricke R; Trenckmann H; Bredel P
Z Gesamte Inn Med; 1975 Nov; 30(22):730-4. PubMed ID: 1210475
[TBL] [Abstract][Full Text] [Related]
39. A rare case of late right ventricular perforation by a passive-fixation permanent pacemaker lead.
Tziakas D; Alexoudis A; Konstantinou F; Chalikias G; Stakos D; Bougioukas G
Europace; 2009 Jul; 11(7):968-9. PubMed ID: 19443432
[TBL] [Abstract][Full Text] [Related]
40. Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads.
Lin G; Nishimura RA; Connolly HM; Dearani JA; Sundt TM; Hayes DL
J Am Coll Cardiol; 2005 May; 45(10):1672-5. PubMed ID: 15893186
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]